background image

0508082120/101203/C

Page 10

Owner’s manual

Technical Repair Guide

10 BASIC SERVICE GUIDE

The Basic Service Guide should cover most performance issues. 
If after checking the items listed, the air cleaner still fails to 
operate properly please contact your distributor.

Condition

Possible cause

Solution

Air cleaner inoperable.

Malfunctioning safety switch.

Properly close the extraction grid or contact your 
service person.

Disconnected from power.

Reconnect power. 

Faulty cord or plug.

Distributor to replace the cord or plug.

Faulty hardware and/or software.

Contact your distributor for replacement parts.

Poorly operating or malfunctioning 
remote control.

(Nearly) exhausted battery.

Check the red led above the 

 button on the 

remote control by pressing any button. Replace the 
battery if the led is not activated.

Fan fails to rotate.

Defective fan.

Contact your distributor for replacement parts.

Faulty hardware and/or software.

Contact your distributor for replacement parts.

Fan works but the air cleaner 
functions poorly or not at all.

One or more filters are polluted.

Replace or clean the filters.

Vents are closed.

Open one or more of the vents (see section 5).

Dirt in the electronic filter causes a short-circuit 
(

STANDBY

 led blinks)

Clean the electronic filter.

Crackling sound from the electronic 
filter.

Electronic filter dirty or wet.

Clean or dry the electronic filter.

Missing prefilter.

Install prefilter.

The air cleaner cannot be 
controlled manually.

Control is locked out.

See Program Setting # 4 (page 7) to unlock. 

STANDBY

 led blinks.

Dirt in the electronic filter causes a short-circuit.

Clean the electronic filter.

Short-circuit in the electronic filter by a broken 
ionizing wire and/or bent collector plates.

Contact your distributor.

Air cleaner is in PROGRAM mode.

Push the PROGRAM button on the remote control 
once or several times to scroll through the menu or 
wait for 1 minute.

•••• and • leds blink.

The Service Indicator indicates that the filters are 
clogged.

Clean the electronic filter or replace the media 
filter.

The fan speed does not increase 
when using the Air Quality 
Analyzer.

Fan speed limited.

See Program Setting # 6 (page 8) to change 
maximum fan speed. 

The Air Quality Analyzer starts 
while the atmosphere is apparently 
clean.

Sensor reacts to, for instance, high or low humidity 
or fumes from cleaning agents.

The sensitivity will adjust itself after some time.

Air Quality Analyzer is too sensitive.

Contact your distributor.

Smells are no longer adsorbed.

Activated carbon filter or Odor Free filter is 
saturated.

Replace the activated carbon filter or Odor Free 
filter.

Summary of Contents for ECD1500B

Page 1: ...MCD1200W MCD1200B Electronic Air Cleaner purateur d air lectronique ECS750W ECS750B ECD1500W ECD1500B 2SD1 Electrostatic Air Cleaner 2SD2 Electric Fan OWNER S MANUAL MANUEL OP RATEUR White Rodgers is...

Page 2: ...Cabinet Air Flow Color MCS600W MC Media Cleaner S Single Cabinet 600 Maximum Air Flow CFM W White MCS600B B Bronze MCD1200W D Double Cabinet 1200 Maximum Air Flow CFM W White MCD1200B B Bronze ECS750W...

Page 3: ...e outside of the air cleaner 3 5 CONTROL 4 5 1 Controlling with the panel button 4 5 2 Remote Control operation 4 5 3 Automatic operation auto mode 4 6 PROGRAM SETTINGS 4 6 1 Program Setting 1 Service...

Page 4: ...ssories It will damage the air cleaner or mounts causing the air cleaner to fall Do not remove a wall mounted air cleaner once it is installed Take special care when cleaning a wall mounted air cleane...

Page 5: ...its Ensure that the load capacity of the mounting devices is sufficient to safely support the air cleaner The weights of the air cleaner are maximum 39 9 lbs and 65 5 lbs respectively For the single a...

Page 6: ...lowing program settings allow you to customize the air cleaner operation for your personal preference Program Setting 1 Service Indicator Program Setting 2 Resetting the Service Indicator PROGRAM pres...

Page 7: ...n the cell for over 60 seconds the STANDBY led flashes Power will be interrupted to the cell s for 10 minutes which may allow the cause of the problem e g hair to flow out of the collecting cell After...

Page 8: ...ill light up meaning you have set the pollution level to EXTREME DUTY If you want to go back to one of the previous pollution levels press W Press PROGRAM to confirm setting 1 and to go to setting 2 P...

Page 9: ...of no high voltage to 120 minutes Press V led TURBO will light up meaning you ve set the time of no high voltage to 240 minutes If you want to go back to one of the previous time setting levels press...

Page 10: ...cabinet A moderate amount of arcing or snapping may occur when the unit is turned on This may indicate that the cell s are still damp Turn the unit off and allow it more drying time or go to Program S...

Page 11: ...causes a short circuit STANDBY led blinks Clean the electronic filter Crackling sound from the electronic filter Electronic filter dirty or wet Clean or dry the electronic filter Missing prefilter Ins...

Page 12: ...5 0632 Media filter 2 pcs x x x x x 42 00 27b F825 0633 Media filter 40 pcs x x x x x 800 00 28 F825 0634 Electronic cell x x x x x 84 40 29a F825 0635 Activated carbon filter 72 pcs x x x x x x x x x...

Page 13: ...82120 101203 C Page 12 Owner s manual Parts List 34 24 1 5 3 4 15 11 10 20 19 17 21 23 26 27 PROGRAM AUTO OFF 16 13 14 25 18 12 22 28 29 24 32 30 32 1 3 1 3 2 33 Replacement ionizing wires electronic...

Page 14: ...16 5 1 Commande par le bouton frontal 16 5 2 Commande par la t l commande 16 5 3 Commande automatique mode AUTO 16 6 MODES DE PROGRAMMATION 16 6 1 Mode de Programmation 1 Indicateur Service 16 6 2 Mod...

Page 15: ...ndommager l purateur d air et entra ner des risques de chocs lectriques d incendie ou de blessures corporelles Lors de la fixation des accessoires de montage vitez de forcer les vis pour les serrer vo...

Page 16: ...dessus de l purateur d air N utilisez pas l appareil lorsque le fil lectrique est endommag Ne tirez pas sur le fil pour d brancher l appareil Prot gez le fil contre la chaleur l huile et les objets a...

Page 17: ...ilisation de deux exemplaires du m me kit Pour le montage encastr du mod le simple utilisez le kit d installation F801 0196 Pour le mod le double utilisez le kit d installation F801 0197 Aucun composa...

Page 18: ...rontal la vitesse du ventilateur passe STANDBY Pousez le bouton frontal le ventilateur s arr te OFF En poussant le bouton frontal sans cesse la commande passe la vitesse suivante chaque seconde 5 2 Co...

Page 19: ...normal 7 REPARATION DES PANNES Si les diodes et clignotent C est l Indicateur Service Il vous pr vient de ce qu il est temps de remplacer ou nettoyer le s filtre s Appuyant quelconque bouton les diode...

Page 20: ...du STANDBY clignote bri vement toutes les deux secondes Programmation de l appareil OFF aucune diode ne clignote Appuyez V diode LOW clignote vous avez fix le niveau de pollution sur BASSE Appuyez V d...

Page 21: ...sensibilit la pollution sera r gl e sur lev e Appuyez V diode TURBO est commut et la sensibilit la pollution sera r gl e sur extr me Si vous d sirez retourner sur l une des sensibilit s la pollution p...

Page 22: ...e la capacit de nettoyage du filtre lectronique Utilisez un chiffon humide pour essuyer tous les fils d ionisation en prenant soin de ne pas les endommager C Enlevez le les filtres s lectronique s de...

Page 23: ...z le filtre lectronique Le filtre lectronique cr pite Le filtre lectronique est encrass ou humide Nettoyer le filtre lectronique ou bien le laisser correctement s cher Le pr filtre est manquant Montez...

Page 24: ...x x x 26b F825 0631 Pr filtre 600 pi ces x x x x x x x x x 27a F825 0632 Filtre m dia 2 pi ces x x x x x 27b F825 0633 Filtre m dia 40 pi ces x x x x x 28 F825 0634 Filtre lectronique x x x x x 29a F...

Page 25: ...3 C Page 24 Manuel op rateur Pi ces D tach es 34 24 1 5 3 4 15 11 10 20 19 17 21 23 26 27 PROGRAM AUTO OFF 16 13 14 25 18 12 22 28 29 24 32 30 32 1 3 1 3 2 33 Remplacement des fils d ionisation du fil...

Page 26: ...7 1 2 3 4 A B C D E F G H I J K L M N O P Q click No mm inches A 554 21 81 B 497 19 57 C 463 18 23 D 298 11 73 E 215 8 46 F 92 3 62 6 G 629 24 76 No mm inches H 570 22 44 I 510 20 08 J 470 18 50 K 978...

Page 27: ...101203 C Controlling Indoor Comfort Worldwide Since 1937 St Louis Missouri Markham Ontario 314 577 1300 905 201 470 www white rodgers com The Emerson logo is a trademark and service mark of Emerson E...

Reviews: