6
7
Adjust the water level. (See Nos. 7 & 8 in “Plumbing and Setting the
Water Level”, pages 8 & 9.)
Slide the flanges of the humidifier reservoir into the mounting bracket until
the reservoir’s front flange comes in contact with the edge of the duct.
Secure the humidifier to the duct with the screws provided.
Option B
requires a transition to be
made
, and usually needs duct reinforce
-
ment to hold the humidifier securely in
place.
NOTE:
For this configuration, the humidi
-
fier is mounted on the outside of the ple
-
num, rather than the inside, so as not to
restrict airflow.
DANGER:
Wear safety glasses when
cutting or drilling.
Do not cut or drill
into any air conditioning components or
electrical enclosures during installation.
Electrocution is possible if you come
in contact with a live electrical wire;
blindness can occur if refrigerant con
-
tacts your eyes.
To install Option B:
5.
6.
7.
Option C
requires duct reinforcement
to hold the humidifier securely in place.
DANGER:
Wear safety glasses when
cutting or drilling.
Do not cut or drill
into any air conditioning components or
electrical enclosures during installation.
Electrocution is possible if you come
in contact with a live electrical wire;
blindness can occur if refrigerant con
-
tacts your eyes.
To install Option C:
Place the mounting bracket (provided)
at the selected location on the bottom
of the duct.
Use a marker to trace around the in
-
side of the mounting bracket. Cut out
the duct opening.
CAUTION:
DO NOT
attach the
mounting bracket before the hole in
the ductwork has been cut.
Attach the mounting bracket to the
ductwork with sheet metal screws.
Adjust the water level. (See Nos. 7 &
8 in “Plumbing and Setting the Water
Level”, pages 8 & 9.)
1.
2.
.
4.
Slide the flanges of the humidifier reservoir into the mounting bracket.
Secure the humidifier to the duct with the screws provided.
NOTE:
See separate wiring instruction manual, “Wiring Instructions
for High-Capacity Steam Humidifiers”.
5.
6.
Construct a transition and attach it
to the plenum. (Additional humidifier
support will be necessary for this
configuration.)
Place the mounting bracket (provided)
at the base of the transition.
Use a marker to trace around the
inside of the mounting bracket. Cut
out the duct opening.
CAUTION:
DO NOT
attach the
mounting bracket before the hole in
the ductwork has been cut.
1.
2.
.
Attach the L-shaped bracket to the top/front of the humidifier so that the
vertical wall is toward the reservoir.
Adjust the water level. (See Nos. 7 & 8 in “Plumbing and Setting the
Water Level”, pages 8 & 9.)
Slide the flanges of the humidifier reservoir into the mounting bracket.
Secure the humidifier to the duct with the screws provided.
4.
5.
6.
7.
Figure 4
—Mounting Bracket
Figure 6
—Mounting Bracket
Figure 3
—Option B:
External Side Mount
Figure 5
—Option C: