 6

 7

Adjust the water level. (See Nos. 7 & 8 in “Plumbing and Setting the 

Water Level”, pages 8 & 9.) 
Slide the flanges of the humidifier reservoir into the mounting bracket until 

the reservoir’s front flange comes in contact with the edge of the duct. 
Secure the humidifier to the duct with the screws provided. 

Option  B 

requires  a  transition  to  be 

made

, and usually needs duct reinforce

-

ment  to  hold  the  humidifier  securely  in 

place. 

NOTE: 

For this configuration, the humidi

-

fier is mounted on the outside of the ple

-

num, rather than the inside, so as not to 

restrict airflow. 

DANGER: 

Wear safety glasses when 

cutting  or  drilling. 

Do  not  cut  or  drill 

into any air conditioning components or 

electrical  enclosures  during  installation. 

Electrocution  is  possible  if  you  come 

in  contact  with  a  live  electrical  wire; 

blindness can occur if refrigerant con

-

tacts your eyes. 

To install Option B: 

5.

6.

7.

Option C 

requires duct reinforcement 

to hold the humidifier securely in place. 

DANGER: 

Wear  safety  glasses  when 

cutting  or  drilling. 

Do  not  cut  or  drill 

into  any  air  conditioning  components  or 

electrical  enclosures  during  installation. 

Electrocution  is  possible  if  you  come 

in  contact  with  a  live  electrical  wire; 

blindness can occur if refrigerant con

-

tacts your eyes. 

To install Option C: 

Place the mounting bracket (provided) 

at the selected location on the bottom 

of the duct. 

Use a marker to trace around the in

-

side of the mounting bracket. Cut out 

the duct opening. 

CAUTION: 

DO  NOT 

attach  the 

mounting  bracket  before  the  hole  in 

the ductwork has been cut. 
Attach  the  mounting  bracket  to  the 

ductwork with sheet metal screws. 

Adjust the water level. (See Nos. 7 & 

8 in “Plumbing and Setting the Water 

Level”, pages 8 & 9.) 

1.

2.

.

4.

Slide the flanges of the humidifier reservoir into the mounting bracket. 
Secure the humidifier to the duct with the screws provided. 

NOTE: 

See  separate  wiring  instruction  manual,  “Wiring  Instructions 

for High-Capacity Steam Humidifiers”. 

5.
6.

Construct  a  transition  and  attach  it 

to  the  plenum.  (Additional  humidifier 

support  will  be  necessary  for  this 

configuration.) 
Place the mounting bracket (provided) 

at the base of the transition. 

Use  a  marker  to  trace  around  the 

inside  of  the  mounting  bracket.  Cut 

out the duct opening. 

CAUTION: 

DO  NOT 

attach  the 

mounting  bracket  before  the  hole  in 

the ductwork has been cut. 

1.

2.

.

Attach the L-shaped bracket to the top/front of the humidifier so that the 

vertical wall is toward the reservoir. 
Adjust the water level. (See Nos. 7 & 8 in “Plumbing and Setting the 

Water Level”, pages 8 & 9.) 
Slide the flanges of the humidifier reservoir into the mounting bracket. 
Secure the humidifier to the duct with the screws provided. 

4.

5.

6.
7.

Figure 4

—Mounting Bracket

Figure 6

—Mounting Bracket

Figure 3

—Option B:

External Side Mount

Figure 5

—Option C: 

Duct Center Mount

Summary of Contents for ComfortPlus HSP2000

Page 1: ...rammable Flushing Timer Installation Instructions Operating and Maintenance Instructions CONTRACTOR Read these instructions before install ing or servicing humidifier HOMEOWNER Save this manual for fu...

Page 2: ...INSTRUCTIONS AND INSTALLATION OF THE ELEC TRONIC COMPENSATING HUMIDISTAT PLEASE SEE SEPARATE INSTRUCTIONS ENCLOSED IN THE HUMIDIFIER CARTON Safety Precautions Do not install a humidifier where the su...

Page 3: ...ation configurations the mounting area must be strong enough to support the humidifier s weight when it is full of water approximately 18 lbs and to hold the humidifier in a level position for safe re...

Page 4: ...racket provided at the selected location on the bottom of the duct Use a marker to trace around the in side of the mounting bracket Cut out the duct opening CAUTION DO NOT attach the mounting bracket...

Page 5: ...8 deep plus or minus 1 8 If it is not further adjustment will be necessary 4 5 6 7 Figure 7 Saddle Valve and Fittings If the water level is too high remove enough water from the reservoir to allow th...

Page 6: ...come in contact with sharp edges or hot surfaces This caution applies to step 7 as well Cut a second piece of tubing to reach from the bottom fitting on the flushing timer to the drain See Step 3 Con...

Page 7: ...tasks follow these instructions WARNING Do not touch the humidifier when the operation indicator light is on Always unplug the unit and allow it to cool prior to service or inspection 4 5 6 7 Unplug t...

Page 8: ...is evapo rated Heavy condensation Turn humidistat down enough on windows to eliminate condensation this may be a temporary condition caused by moisture from bath ing mopping cooking etc Humidifier Hi...

Page 9: ...see an immersed tubular heater and two floats When your home is too dry the humidistat humidity control device installed with your system activates the humidifier heater A built in thermostat senses t...

Page 10: ...nd more homeowners are realizing that during the winter months they live in a sick house Family members suffer from dry itchy skin parched throats and annoying coughs Furniture creaks floors moan the...

Page 11: ...ComfortPlus Humidifier or to learn which White Rodgers IAQ products are right for your home contact your local heating and air conditioning contractor Part No 000 0756 314 HBP 6 06 8100 W Florissant A...