White Rodgers 50M56-743 Installation Instructions Manual Download Page 4

4

WIRING 

 

TH

TR

MV HI

MV COM

MV LO

GND

HLO

HLI

PSO

PSI

C

R

G

W

Y

Y

W

G

R

THERMOSTAT

2 STAGE

GAS

VALVE

HIGH LIMIT

(N. C.)

ROLLOUT

(N. C.)

AUX. HIGH

LIMIT (N. C.)

PRESSURE SWITCH (N. O.)

COMPRESSOR

CONTACTOR

ELECTRONIC

AIR CLEANER

CIRCULATOR

BLOWER

50M56

24 VAC

120 VAC

24 VAC CLASS II

TRANSFORMER

HOT

(LINE)

NEUTRAL

(LINE)

FS

FLAME

SENSOR

PROBE

TH

TR

RO OUT

RO IN

TYPICAL SYSTEM WIRING DIAGRAM

Low Voltage (24 VAC)
Line Voltage (120 VAC)

LEGEND

N. C. = Normally closed switch

N. O. = Normally open switch

1 STAGE

GAS

VALVE

[4-Pin Connector]

[12-Pin Connector]

IGNITOR

INDUCER

IGN

IGN-N

IND

IND-N

LINE N

XFMR N

EAC N

CIR N

PARK

EAC

XFMR

LINE

PARK

HI HEAT

LO HEAT

COOL

12-Pin Connector

HLO

PSO

HLI

PSI

GND

TH

TR

MV

LO

RO

OUT

RO

IN

MV

COM

MV

HI

4-Pin Connector

IND

IGN

IND

N

IGN

N

Summary of Contents for 50M56-743

Page 1: ...instructions to ensure proper operation PRECAUTIONS CAUTION Do not short out terminals on gas valve or primary control Short or incorrect wiring may damage the thermostat Failure to comply with the fo...

Page 2: ...to allow for the dissipation of any unburned gas or residual products of combustion between the failed trial for ignition and the retry period 60 Post Purge The period of time intended to allow for th...

Page 3: ...ire is recommended for all line voltage connections Afterinstallationorreplacement followappliancemanufacturer s recommended installation or service instructions to ensure proper operation Do not shor...

Page 4: ...NSFORMER HOT LINE NEUTRAL LINE FS FLAME SENSOR PROBE TH TR RO OUT RO IN TYPICAL SYSTEM WIRING DIAGRAM Low Voltage 24 VAC Line Voltage 120 VAC LEGEND N C Normally closed switch N O Normally open switch...

Page 5: ...de ignitor NEUTRAL side W G R Y C HLO Pin 1 MV LO Pin 2 TH Pin 3 PSO Pin 4 RO OUT Pin 5 TR Pin 6 HLI Pin 7 GND Pin 8 MV COM Pin 9 PSI Pin 10 RO IN Pin 11 MV HI Pin 12 IND Pin 1 IGN Pin 2 IND N Pin 3 I...

Page 6: ...ges for comfort Auto will adapt the delay to energize MV HI from instantly to up to 12 minutes When the thermostat is satisfied the gas valve is de energized After proof of flame loss the heat delay t...

Page 7: ...fault codes stored can be displayed on the diagnostic LED When the control is in standby mode no call for heat or cool press the FAULT RECALL switch for approximately two seconds or until the diagnost...

Page 8: ...fficient vacuum to engage switch Refer to wiring diagram terminals PSI PSO 4 Open high temperature limit switch Verify continuity through limit switch circuit Refer to wiring diagram terminals HLI HLO...

Reviews: