White Rodgers 50M56-743 Installation Instructions Manual Download Page 1

50M56-743

Integrated Single or Two-Stage

HSI Integrated Furnace Control Kit

INSTALLATION INSTRUCTIONS

 

 DESCRIPTION

The 50M56-743 kit is an automatic gas HSI Integrated Fur-
nace Control that employs a microprocessor to continually 
monitor, analyze, and control the proper operation of the gas 
burner, inducer, and fan.
Signals interpreted during continual surveillance of the ther-
mostat and flame sensing element initiate automatic ignition 
of the burner, sensing of the flame, and system shut-off during 
normal operation.
These controls incorporate system fault analysis for quick gas 
flow shut-off, coupled with automatic ignition retry upon sensing 
a fault correction.

Installation should be done by a qualified heating and air 
conditioning contractor or licensed electrician.
If in doubt about whether your wiring is millivolt, line, or low 
voltage, have it inspected by a qualified heating and air 
conditioning contractor or licensed electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes 
and ordinances.
This control is a precision instrument, and should be handled 
carefully. Rough handling or distorting components could 
cause the control to malfunction.
Following installation or replacement, follow manufacturer’s 
recommended installation/service instructions to ensure 
proper operation.

 

 PRECAUTIONS

CAUTION

!

Do not short out terminals on gas valve or primary 
control. Short or incorrect wiring may damage the 
thermostat.

Failure to comply with the following warnings could result 
in personal injury or property damage.

FIRE HAZARD

•  Do not exceed the specified voltage.
•  Replace existing control with exact model and 

dash number.

•  Protect the control from direct contact with water 

(dripping, spraying, rain, etc.).

•  If the control has been in direct contact with 

water, replace the control.

•  Label all wires before disconnection when 

servicing controls. Wiring errors can cause 
improper and dangerous operation.

•  Route and secure wiring away from flame.

SHOCK HAZARD

•  Disconnect electric power before servicing.
•  Ensure proper earth grounding of appliance.
•  Ensure proper connection of line neutral and line 

hot wires.

EXPLOSION HAZARD

•  Shut off main gas to appliance until installation 

is complete.

WARNING

!

CONTENTS

Description ................................................................... 1
Precautions .................................................................. 1
Specifications .............................................................. 2
Installation ................................................................... 3
           Mounting & Wiring
Operation ..................................................................... 6
System Lockout and Diagnostic Features ................... 7
Troubleshooting ........................................................... 8

www.white-rodgers.com

www.emersonclimate.com

PART NO. 37-7474A

1314

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE 
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL 
INJURY AND/OR PROPERTY DAMAGE.

Operator: Save these instructions for future use!

50M56-743 Cross Reference Information

Goodman

White-Rodgers 

0130F00006

PCBBF122

50M56 289

0130F00006S

PCBBF122S

PCB00109

PCBBF132

PCBBF109

PCBBF132S

 

Summary of Contents for 50M56-743

Page 1: ...instructions to ensure proper operation PRECAUTIONS CAUTION Do not short out terminals on gas valve or primary control Short or incorrect wiring may damage the thermostat Failure to comply with the fo...

Page 2: ...to allow for the dissipation of any unburned gas or residual products of combustion between the failed trial for ignition and the retry period 60 Post Purge The period of time intended to allow for th...

Page 3: ...ire is recommended for all line voltage connections Afterinstallationorreplacement followappliancemanufacturer s recommended installation or service instructions to ensure proper operation Do not shor...

Page 4: ...NSFORMER HOT LINE NEUTRAL LINE FS FLAME SENSOR PROBE TH TR RO OUT RO IN TYPICAL SYSTEM WIRING DIAGRAM Low Voltage 24 VAC Line Voltage 120 VAC LEGEND N C Normally closed switch N O Normally open switch...

Page 5: ...de ignitor NEUTRAL side W G R Y C HLO Pin 1 MV LO Pin 2 TH Pin 3 PSO Pin 4 RO OUT Pin 5 TR Pin 6 HLI Pin 7 GND Pin 8 MV COM Pin 9 PSI Pin 10 RO IN Pin 11 MV HI Pin 12 IND Pin 1 IGN Pin 2 IND N Pin 3 I...

Page 6: ...ges for comfort Auto will adapt the delay to energize MV HI from instantly to up to 12 minutes When the thermostat is satisfied the gas valve is de energized After proof of flame loss the heat delay t...

Page 7: ...fault codes stored can be displayed on the diagnostic LED When the control is in standby mode no call for heat or cool press the FAULT RECALL switch for approximately two seconds or until the diagnost...

Page 8: ...fficient vacuum to engage switch Refer to wiring diagram terminals PSI PSO 4 Open high temperature limit switch Verify continuity through limit switch circuit Refer to wiring diagram terminals HLI HLO...