24309-1-0908
Page 17
The fireplace is designed to accept a gas line for connection to the
gas valve. Have the line installed by a qualified service person in
accordance with all building codes. Consult local building codes
to properly size the gas supply line leading to the connection of the
valve. The state of Massachusetts requires that a flexible appliance
connector cannot exceed three feet in length.
Gas access holes are provided through the side panel(s) of the
fireplace.
See figure 14
.
Check gas type. Use only the gas type indicated on the rating plate.
If the gas listed on the plate is not your type of gas supply, DO NOT
INSTALL. Contact your dealer for proper model.
Always use an external regulator to reduce the supply tank pressure
to a maximum of 10.5" w.c. (NAT), or 13" w.c. (LP) See page
10.
WARNING: CONNECTION DIRECTLY TO AN
UNREGULATED L.P. TANK CAN CAUSE EXPLOSION.
figure 14
gAS LINE CONNECTION
GAS LINE
ACCESS
HOLES