TROUBLESHOOTING 

 

PROBLEM 

CAUSE 

REMEDY 

Fan doesn’t work.  

1.

 

No electricity. 

 

2.

 

Blade stalled by housing. 

1.

 

Check power Supply 

 

2.

 

Call White Marquee 

 

Piezo will no ignite. 

1.

 

Ignition cable damaged. 

 

2.

 

Ignition cable disconnected. 

 

3.

 

Distance between electrode and 

burner too large. 

1.

 

Call White Marquee 

 

2.

 

Call White Marquee 

 

3.

 

Adjust distance within 3-8min 

 

No gas. 

1.

 

Gas cylinder is empty.  

 

2.

 

Gas valve on cylinder closed. 

 

3.

 

Gas valve of heater not open. 

1.

 

Replace new gas cylinder. 

 

2.

 

Open the valve.  

 

3.

 

Attempt re-light sequence correctly.  

 

Flame goes out while 

heater is running.  

1.

 

Thermo-element was not heated 

enough.  

 

 

2.

 

Safety thermostat activated.  

 

 

 

3.

 

Restricted air flow. 

1.

 

Repeat ignition process and keep safety gas valve 

depressed for a minimum of 5 seconds, then release 

slowly.  

 

2.

 

Allow the heater to cool down for at least 10 

minutes. Check thermostat and the attempt re-light 

sequence correctly.  

 

3.

 

Check heater inlet and outlet, remove any 

obstructions.  

 

 

SPECIFICATIONS 

Rated voltage 

220V-240V-50H 

Rated output 

80W 

Heat output 

70Mj/hr 

Air flow 

500m3/h 

Gas consumption 

1.42kg/h. 

Weight (approx.) 

8.5kg 

Min gas cylinder size 

15kg 

Minimum volume of room 

360m3 

 

 

 

 

 

 

 

   