11
“LPS” (Compressor Low Pressure)
• Evaporator coil dirty.
• Fan motor not running.
• Low refrigerant pressure.
• Defective low-pressure switch.
• Low ambient air temperature.
“ESO”
• Evaporator temperature sensor connection opened. Check for cut or loose sensor wiring
or defective sensor.
“tSO”
• Water temperature sensor connection opened. Check for cut or loose sensor wiring or
defective sensor.
“ESS”
• Evaporator temperature sensor connection shorted. Check for a short in sensor wiring or
defective sensor.
“tSS”
• Water temperature sensor connection shorted. Check for a short in sensor wiring or
defective sensor.
“DEF”
• Heat pump in defrost cycle.
• Please eliminate any water flow problems before calling for service.
• If you are unable to contact the installing agent, please contact OXYGEN POOLS, LLC
A factory representative will assist you or your serviceman o ver the phone.
SERVICE PERFORMED WITHIN THE WARRANTY PERIOD MUST BE APPROVED BY WHITE KNIGHT
PRIOR TO SERVICE BEING PERFORMED AND ONLY BY A WHITE KNIGHT AUTHORIZED TECHNICIAN.
SEE WARRANTY FOR DETAILS.
Please have the following ready before calling:
MODEL #:
SERIAL #:
DATE OF INSTALLATION:
NAME OF OWNER:
ADDRESS:
CONTACT # :
NATURE OF PROBLEM:
ANALYZER CODES
(Cont.)
CALLING FOR SERVICE
877-246-9943