Summary of Contents for BG 43A

Page 1: ...ety Installation and Use Regulations 1998 Guidance may be obtained from the relevant parts of B S 6172 B S 5440 parts 1 and 2 B S 7624 2004 B S 6891 current editions I E E Wiring Regulations and relevant Building Regulations Failure to install the appliance correctly could invalidate the warranty liability claims and could lead to prosecution FOR USE IN GREAT BRITAIN AND EIRE WITH NATURAL GAS ONLY...

Page 2: ...L REGULATIONS IN FORCE AND ONLY IN A WELL VENTILATED SPACE READ THE INSTRUCTIONS BEFORE USING OR INSTALLING THIS APPLIANCE THIS APPLIANCE CONFORMS TO THE FOLLOWING EEC DIRECTIVES LOW VOLTAGE DIRECTIVE LVD 73 23 EEC EN60 335 1 EN60 335 2 11 GAS APPLIANCE DIRECTIVE GAS 90 396 EEC BS 5258 PART 17 1992 EN 1458 1 2000 ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89 336 EEC EN55014 EN 61000 3 2 EN 61000 3 3 ...

Page 3: ...t split capacitor 8μF 4 pole Approx 1 8 HP Overload protection approx 130 C BURNER Pressed steel with slotted flame perforations Heat input 3 0kW 10235 Btu hr Injector 1 32 mm dia CONTROL Type Pactrol full sequence flame control P16A GTD CE 414601 Ignition electrode gap to burner 3 to 4mm Flame failure electrode 4213 078 52641 Height from heater base to centre of electrode 27 0 0 5mm INLET THERMOS...

Page 4: ...aces 4 VENTING The dryer must be fitted with an exhaust vent hose and the end either hung out of a window or fitted to a wall window vent connection Note Do not obstruct or add a mesh to the vent hose outlet during use and ensure that it cannot be blocked or bent sharply which obstruct the air flow It is recommended that the interior of the hose be periodically inspected and cleaned if necessary P...

Page 5: ...ed tumble dryers 9 STACKING Instructions for stacking if required are supplied with the stacking kit PROGRAMME Clockwise rotation of the control knob closes switch contacts within the timer to a energise the drive motor and b energise the full sequence flame controller The timer switch controlling the drive motor and the timer motor remains closed until the timer motor mechanism returns the contro...

Page 6: ...way Housing 31 to release the wiring from the Heater Assy to the Cabinet Lay the dryer flat on its front supported to take the weight from the door and controls Withdraw the 6 screws securing the Cover Piate 19 to the Back Panel 24 and remove it Pull out the Exhaust Tube 30 Withdraw the 4 screws securing the Hot Air Elbow Assy 20 to the Back Panel 24 and remove it Disconnect the External Feed Pipe...

Page 7: ... there is a fault in the valves burner or other parts of the gas line then the Heater Assy 32 must be replaced INLET THERMOSTAT THERMAL OVERLOAD CUT OUT TOC REMOVAL Lay the dryer flat on its front supported to take the weight from the door and controls Withdraw the 6 screws securing the Cover Plate 19 to the Back Panel 24 and remove it Pull out the Exhaust Tube 30 Disconnect the Faston connectors ...

Page 8: ... Use each chart to locate the fault causing the dryer to operate incorrectly as follows Chart No 1 Motor does not run 2 Motor runs but full sequence control does not produce ignition spark 3 Motor runs Full Sequence Control produces ignition sparks but gas does not ignite 4 Motor runs gas ignites but burns for only a short period Chart 1 Motor does not run ...

Page 9: ...k with high heat selected Disconnect both red wires at timer B2 Reconnect only red wire from heat selector to timer B2 Caution the other red wire is live Is voltage between heat selector switch and TB N 230V With red wire still disconnected is voltage between output of heat selector switch and TB N 230V at high heat setting and zero volts at low setting Is voltage between brown wire in control box...

Page 10: ...10 Chart 3 Motor runs Full Sequence Control produces ignition sparks but gas does not ignite ...

Page 11: ...ressure Is flame failure electrode correctly positioned and undamaged Is wire to terminal 9 undamaged and connections tight Is rear drum seal complete Is rear elbow and plinth attached correctly Exchange full sequence control and or gas control relay PCB and or thermostats as necessary until gas stays on Machine operating Instruct user as necessary Yes Yes Yes Start Check gas pressure with all oth...

Page 12: ...12 WHITE KNIGHT BG 43A_ CROSSLEE P L C ...

Page 13: ...13 WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 1 ...

Page 14: ...14 WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 2 REAR ASSEMBLY VIEWED FROM FRONT ...

Page 15: ...15 WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 3 INTERNALS VIEWED FROM REAR ...

Page 16: ...WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 4 INTERNALS VIEWED FROM REAR 16 ...

Page 17: ...17 WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 5 HEATER ASSEMBLY ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...BG 43A_ Installation Service Book 4213 094 67791 Manufactured by Crosslee plc Lightcliffe Factory Hipperholme Halifax West Yorkshire HX3 8DE ...