Whisper Power M-GV 10 Installation Manual Download Page 12

 
 
 
ELECTRICAL INSTALLATION 

12

 

M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10 and M-GV 15 — June 2017 — EN

 

ELECTRICAL INSTALLATION 

3.1 

DIGITAL DIESEL CONTROL SYSTEM 

The  standard  electrical  control  system  is  in  12  Volt  with 
negative earth. Non-earth return is available as an option. The 
engine is controlled by a highly advanced microprocessor based 
system:  Digital  Diesel  Control,  which  has  both  a  local  control 
and a remote panel. 

3.2 

REMOTE CONTROL 

A  remote  control  panel  also  containing  a  microprocessor  is 
included  in  the  delivery,  as  well  as  a  10 m  8-pole 
communication  cable  (Figure 19).  Other  lengths  are  available 
on  request.  A  longer  (up  to  30 m)  cable  can  be  connected  if 
required.  For  distances  exceeding  30 m,  please  consult  the 
WhisperPower service department. 

 

Figure 19: Remote control cable

 

The control panel can  be  mounted in the dashboard using the 
plastic sawing template. For dimensions, refer to the drawings 
in Chapter 5. 

Two  more  remote  control  panels  (slave  panels)  can  be  put  in 
parallel using the modular connectors on the back of the units. 
Actually,  the  slaves  are  regular  remote  control  panels  offering 
all functions again. 

When using the factory settings, installation is very simple: just 
plug in both end of the communication cable and the genverter 
is ready to use. 

3.3 

ACOUSTIC ALARM OR WARNING LAMP  

An  external  max.  150  mA  relay  can  be  connected  in  order  to 
generate  an  acoustic  warning,  light  a  warning  lamp,  etc.  Be 
aware of polarity as some relays have a diode inside and must 
be  connected  positive  to  positive  and  negative  to  negative  as 
indicated (Figure 20). 

 

Figure 20: Remote box terminals 

 

3.4 

CONNECTION  FOR  EMERGENCY  STOP  / 

FIRE ALARM SWITCH 

 

 

Figure 21: Connection for emergency stop / fire alarm switch 

 

To connect an emergency stop button or to stop the generator 
automatically  in  case  of  a  fire  alarm,  you  can  use  the  bypass 
connection between fastons J7 and J18 on the backside of the 
local  control  panel  (Figure 21).  To  do  so,  remove  this  bypass 
connection  and  then  replace  it  by  an  emergency  switch  or  a 
potential free fire alarm switch with normally closed contacts.  

 

Remove bypass 
between J7 - J18 

Normal operation 

Alarm / emergency 

local control panel  

(rear view) 

Summary of Contents for M-GV 10

Page 1: ...LLATION MANUAL M GV 2 M GV 3 M GV 3 M GV 8 M GV 10 and M GV 15 genverters for marine use WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel 31 512 571550 Fax 31 512 571599 www whisperpower...

Page 2: ...cooling 7 2 9 Wet exhaust system 9 2 9 1 General 9 2 9 2 Standard exhaust system 9 2 9 3 Super silent exhaust system 10 3 ELECTRICAL INSTALLATION 12 3 1 Digital Diesel Control system 12 3 2 Remote con...

Page 3: ...tained in this manual apply solely to standard versions of the two and three cylinder genverters delivered by WhisperPower This manual is valid for the following models Refer to the user s manual for...

Page 4: ...itions that may affect the engine and electronics The air inlet of the engine room must be protected against the ingress of water and it is recommended to fit an air inlet strainer for protection agai...

Page 5: ...t the top of the engine compartment to evacuate the hottest air An engine compartment blower should be used as an extraction ventilator to remove air from the engine room In cases where it is impossib...

Page 6: ...e top Interference of the two systems propulsion engine and genverter should be avoided Emptying the tank below the level of the suction pipe of the genverter could make it necessary to bleed the fuel...

Page 7: ...or seawater After the raw water is warmed up in the heat exchanger it is dumped overboard by injecting it in the exhaust 2 8 2 The internal cooling system The internal cooling system should be filled...

Page 8: ...appropriate water strainer with connections of well accessible position 5 cm above the waterline Figure 13 ref 6 2 8 4 5 Siphon breaker air vent When the point of water injection is below the waterli...

Page 9: ...st point of the exhaust system see Figure 10 ref 1 The exhaust hose must have an inner diameter of 40 mm 1 5 8 The exhaust system must be installed so that the back pressure inside the exhaust does no...

Page 10: ...ck is not required If the through hull exhaust outlet has to be mounted far from the generating set i e the length of the exhaust piping from the generator to the top of the goose neck water separator...

Page 11: ...ost inaudible For optimal noise reduction the sea water outlet from the exhaust water separator centre outlet on the unit see Figure 17 should be installed below the water level to eliminate noisy spl...

Page 12: ...el using the modular connectors on the back of the units Actually the slaves are regular remote control panels offering all functions again When using the factory settings installation is very simple...

Page 13: ...tery should be connected check polarity to the connector on the back of the remote panel Figure 20 The sense wires must be connected directly to the second battery and be protected by a 3A fuse Settin...

Page 14: ...Special attention has to be paid on dividing the system in branches which are fused individually It is absolutely essential that each and every circuit in the electrical system be properly installed b...

Page 15: ...ine and check if the lift of the fuel is less than 1 m Check if there is no air in the water fuel separator 9 Check if the air intake in the canopy is not blocked 10 Check the oil level and colour of...

Page 16: ...28 mm 6 2 50221007 Male hose connector 20 mm 7 1 50230060 Nickel plated brass intake strainer TOTAL 40230211 WATER INLET KIT 20 mm for M GV 2 M GV 3 M GV 8 and M GV 10 no qty article no description di...

Page 17: ...bly 20 mm 2 4 50221502 Hose clamp 19 29 mm 3 3 m 50220056 Raw water hose 19 28 mm TOTAL 40230273 SYPHON BREAKER KIT 20 mm for M GV 2 M GV 3 M GV 8 and M GV 10 no qty article no description dimensions...

Page 18: ...5 50 mm 23 2 5m 50220033 Marine exhaust hose 40 mm 31 1 50221015 Male hose connector 1 40 mm 32 1 50230044 Lever operated ball valve f f 1 33 1 50230033 Brass through hull fitting 1 70 mm 34 1 4023019...

Page 19: ...pple 8 mm TOTAL 40230205 FUEL KIT OPTIONAL INSTALLATION MATERIALS no qty article no description dimensions 48 1 50221522 Hose clamp stainless 10 16 mm not shown per m 50222020 copper fuel pipe 6 8 mm...

Page 20: ...DIAGRAMS DRAWINGS 20 M GV 2 M GV 3 M GV 3 M GV 8 M GV 10 and M GV 15 June 2017 EN 5 DIAGRAMS DRAWINGS 5 1 ELECTRICAL DIAGRAMS Figure 24 Layout of M GV 8 and M GV 10 genverter systems...

Page 21: ...DIAGRAMS DRAWINGS M GV 2 M GV 3 M GV 3 M GV 8 M GV 10 and M GV 15 June 2017 EN 21 Figure 25 Layout of M GV 15 genverter system...

Page 22: ...DIAGRAMS DRAWINGS 22 M GV 2 M GV 3 M GV 3 M GV 8 M GV 10 and M GV 15 June 2017 EN Figure 26 Electrical control diagram...

Page 23: ...DIAGRAMS DRAWINGS M GV 2 M GV 3 M GV 3 M GV 8 M GV 10 and M GV 15 June 2017 EN 23 5 2 MECHANICAL DRAWINGS Figure 27 M GV 2 and M GV 8...

Page 24: ...DIAGRAMS DRAWINGS 24 M GV 2 M GV 3 M GV 3 M GV 8 M GV 10 and M GV 15 June 2017 EN Figure28 M GV 3 and M GV 10...

Page 25: ...DIAGRAMS DRAWINGS M GV 2 M GV 3 M GV 3 M GV 8 M GV 10 and M GV 15 June 2017 EN 25 Figure 29 M GV 3 and M GV 15...

Page 26: ......

Page 27: ......

Page 28: ...Kelvinlaan 82 9207 JB Drachten Netherlands Tel 31 512 571550 Fax 31 512 571599 www whisperpower com info whisperpower com...

Reviews: