Receiving and Inspecting the System 

• 

Inspect the packaging for any obvious signs of damage or mishandling before opening the container. 

• 

Note any discrepancies or visual damage on the Bill of Lading before signing. 

Review the Packing Slip to Verify Contents

• 

Check the model number to ensure it is correct. 

• 

Check that all factory options ordered are listed. 

If any items listed on the packing slip do not match your order information,

contact WhisperKOOL Customer Service immediately. 

Before You Start
1.   Inspect the Kit before installation.

 If damage is found, please contact your distributor or WhisperKOOL 

Customer Service at 1-800-343-9463.

2.  Verify that you have received all of the items on the “Components Provided” list below and that the Kit 

corresponds to your specific WhisperKOOL cooling system.

3.  The system is intended 

for use in properly designed and constructed wine cellars.

 Hire a professional wine 

storage consultant with a valid contractor’s license to build your wine cellar.

4.  WhisperKOOL requires that all Systems and Cold Weather Start Kits be installed by a certified HVAC-R technician only.
5.  The system is intended 

for use in properly designed and constructed wine cellars.

 Hire a professional wine 

storage consultant with a valid contractor’s license to build your wine cellar.

6.  Warranty is not active until a Warranty Checklist has been received, reviewed, and approved.

RECEIVING & INSPECTING THE SYSTEM

After verifying that you have received all of the correct components for your specific system, please keep the Cold 

Weather Start Kit in its original box until you are ready for installation. This will allow you to move the product safely 

without damaging it. When you are ready to remove the product from the box, refer to the installation instructions. 

TIP:

 Save your box and all packaging materials. They provide the only safe means of transporting/shipping the unit. 

Condensing Unit Components Provided:

 

• 

(1) Omron relay Assembly

• 

(1) Bypass timer

• 

(1) Thermal Switch Assembly

• 

(1) Blue disconnect labeled 3

• 

(20) small white zip ties

• 

(1) zip lock bag containing thermal paste

• 

(2) 40 watt 120v silicone heaters

• 

(2) hose clamps

• 

(1) Magnacraft Relay Assembly

• 

(1) #13 Wire

• 

(1) closed end terminal

• 

(1) Set of AKA4460 Cold Weather Start Kit 

Field Installation Instructions

• 

(1) Schematic Sticker

• 

(2) Silicone Heaters

Components Needed (Not provided): 

• 

2 wire t-stat wire for routing from the 

evaporator unit (Air Handler) to the 

condensing unit. 

• Use 18-20 wire stranded or solid

Tools Needed:

 

• 

#1 Philips Head Screw Driver

• 

#2 Philips Head Screw Driver

• 

5/16” Nut Driver

• 

1/4” Nut Driver

• 

Drill

• 

Wire Cutters

• 

Wire Strippers

• 

Crimpers

• 

Needle Nose Pliers

• 

Utility Knife

Evaporator Unit Components Provided: 

• 

(4) Lever Connectors

• 

(1) 120v/24v Transformers (with double 

sided tape on bottom edge for mounting)

• 

(5) Zip Ties (3 for install and 2 additional)

• 

Platinum Split/WM & FD Evaporator Unit 

Cold Weather Start Kit Field Installation 

Instructions

Summary of Contents for Ceiling Mount 8000

Page 1: ... CM8000 051515 The Coolest Thing In Wine Storage Cold Weather Start Kit To be used in conjunction with Ceiling Mount 8000 Manufactured After 01 07 15 cooling system COLD WEATHER START KIT Ceiling Mount 8000 ...

Page 2: ...KOOL is not responsible for printing or clerical errors WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice Vinothèque and WhisperKOOL are registered trademarks and ECE is a trademark of WhisperKOOL All rights reserved Mention of third party products is for informational purposes only and constitutes ...

Page 3: ... com Page 1 TABLE OF CONTENTS Receiving Inspecting the System 3 Before You Start 4 Condensing Unit Cold Weather Start Kit Installation Instructions 5 Evaporator Unit Cold Weather Start Kit Installation Instructions 19 ...

Page 4: ... Manual carefully and keep it for future reference What is a Cold Weather Start Kit The Cold Weather Start Kit is designed to insure the start of your cooling system despite frigid ambient temperature that may result in failure of unit operation The Cold Weather Start Kit will provide heat to the condensing unit when ambient temperature is too low How Does the Cold Weather Start Kit Work The Cold ...

Page 5: ...nty Checklist has been received reviewed and approved RECEIVING INSPECTING THE SYSTEM After verifying that you have received all of the correct components for your specific system please keep the Cold Weather Start Kit in its original box until you are ready for installation This will allow you to move the product safely without damaging it When you are ready to remove the product from the box ref...

Page 6: ... Power going to the Evaporator and Condensing Unit WARNING Failure to do so may cause electrical shock which can result in injury or death A 2 wire 18 20 awg thermostat wire will need to be ran from the evaporator unit to the condensing unit prior to installing the Cold Weather Start Kit Review the Tools Needed and Components Provided document prior to starting ...

Page 7: ...ce one of the silicone heaters on the receiver in the location shown The heater will not adhere completely there are hose clamps installed later in these instructions that will keep them firmly in place NOTE Line up the heater so the wires are located at the fan shroud and the bottom of the heater is touching the liquid line Peel the backing off the other silicone heater 1 2 3 4 ...

Page 8: ...s are directed toward the fan shroud and the back edge of the heater is touching the back edge of the other heater as shown Slide the hose clamps on the receiver over the silicone heaters One at the top of the heaters and one at the bottom Secure in place as shown Wrap the spring from the Thermal Switch Assembly around the liquid line and secure the clasp of the spring to the thermal switch as sho...

Page 9: ...om terminal on the thermal switch Using a Phillips head screw driver remove the screw on the front edge of the electrical box Using a Phillips head screw driver remove the screw on the back edge of the electrical box Lift the top and remove it from the electrical box 9 10 11 12 ...

Page 10: ...er connector Using a flat head screw driver loosen the six terminal screws outlined in red and remove the wires from the terminals Cut the zip tie holding the high and low pressure wires Remove the adhesive backing from the bottom of the Magnacraft Relay Assembly 13 16 14 15 ...

Page 11: ...ntation shown Press the relay assembly firmly in place Remove the adhesive backing from the Omron Relay Assembly Place the Omron Relay Assembly in the electrical box in the orientation shown Press the relay assembly firmly in place Using a flat head screw driver remove the cable tie holder 17 18 19 20 ...

Page 12: ...the bypass timer inside the electrical box in the orientation shown Press the relay assembly firmly in place Route the 10 wire with the blue disconnect labeled T down through the cord squeeze Connect the blue disconnect labeled T from the 10 wire to the top terminal on the thermal switch 21 22 23 24 ...

Page 13: ...p into the electrical box through the cord squeeze Pull the slack out of the wires and zip tie them in the locations shown Zip tie the wires to the fan shroud as shown Connect the 9 wire with the blue disconnect labeled 6 to the 6 terminal on the Omron Relay 25 26 27 28 ...

Page 14: ... splice high pressure switch Secure one low pressure switch wire and one high pressure switch wire inside the H1 lever connector Blue Wires low pressure switch Black Wires with butt splice high pressure switch Zip tie the wires going into the N1 and H1 lever connectors as shown Connect the 2 wire with the red disconnect labeled 1 to the 1 terminal on the bypass timer 29 30 31 32 ...

Page 15: ...mer Connect the other end of the 13 wire with the blue disconnect labeled 4 to the 4 terminal on the Omron relay Connect the 5 wire with the red disconnect labeled 3 to the 3 terminal on the bypass timer Using the closed end terminal crimp the 1 wire with the remaining low pressure switch wire 33 34 35 36 6 4 2 2 3 1 ...

Page 16: ...white wire from the 3 terminal on the terminal block inside of the N lever connector Remove the blue disconnect from the 3 terminal on the Delay on Break Timer Crimp the blue disconnect labeled 3 onto the loose wire coming from the Johnson control It was disconnected from the terminal block in step 16 37 38 39 40 ...

Page 17: ...he wire that was connected to the 3 terminal of the Delay on Break Timer Strip the end of the wire to a length of 3 8 41 42 Secure the bare end of the wire from the 1 terminal on the Delay on Break timer inside of the C lever connector Secure the bare end of the wire coming from the 0 terminal on the compressor contactor relay inside of the C lever connector 43 44 ...

Page 18: ...al 2 on the terminal block Route the 24v thermostat wires into the electrical box through the cord squeeze Connect one of the 24v thermostat wires to the grey 12 wire the using the wire nut provided Connect the other 24v thermostat wire to the purple 11 wire the using the wire nut provided 46 45 47 48 ...

Page 19: ...ions shown Make sure that no wires are touching the resistor when complete Remove the schematic sticker from the electrical box top Peel the adhesive backing off of the schematic sticker Apply the schematic sticker to the electrical box top as shown 50 49 51 52 ...

Page 20: ...er of the zip lock bag containing the thermal paste Apply thermal paste to the surface of the thermal switch Set thermal switch in location shown making sure the surface of the switch is making good contact with the receiver 54 53 55 56 The Cold Weather Start Kit has been successfully installed on the condensing unit next proceed to the evaporator unit instructions ...

Page 21: ...her Start Kit All parts for the Evaporator Unit are located inside of this box Open box and remove the 24v transformer and the zip lock bag The kit will include five zip ties four lever connectors one 6 32 kep nut and one 120v 24v step down transformer Using a Phillips head screw driver remove the 8 screws holding the grill in place Set screws aside for later use 1 2 3 4 ...

Page 22: ...ll Locate the electrical panel access door and remove the two Phillips head screws Set screws and panel aside for later use Remove the thumbscrew by rotating it counter clockwise Set thumbscrew aside for later use Pull electrical panel down as shown 5 6 7 8 ...

Page 23: ...other edge over the 6 32 stud See next step for transformer orientation for units equipped with the humidity option Push transformer against the electrical panel and secure it in place using the 6 32 nut provided Make sure there is a distance of 1 16 between the transformer and the capacitor Cut the zip tie off the wires entering the control box 9 10 12 13 ...

Page 24: ...each end to a length of 3 8 Secure the two blues from the unit and the black wire from the transformer into a lever connector Locate the white 16awg white wire coming out of the control box Note There may be other wires with white insulation around them they will be a little thicker do not cut those wires 14 15 16 17 ...

Page 25: ...e one of the thermostat wires and the yellow wire from the transformer into a lever connector Note The thermostat wire is the wire that was ran from the evaporator unit to the condensing unit Secure the other thermostat wire and the blue wire from the transformer into a lever connector Note The thermostat wire is the wire that was ran from the evaporator unit to the condensing unit 18 19 20 21 ...

Page 26: ...ires in locations shown Tuck lever connectors into location shown Push electrical panel back up inside the unit and reinstall the thumbscrew removed in step 8 Re install the electrical panel using the 2 Phillips head screws removed in step 7 22 23 24 25 ...

Page 27: ...the Evaporator Unit If the installation process is complete on the condensing unit as well plug both the condensing unit and evaporator units back into a power source Install the grill back on the evaporator unit and secure it to the unit using the 8 Phillips head screws removed in step 5 26 ...

Page 28: ...CWSK CM8000 051515 WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com ...

Reviews: