background image

5

Rectangular to Round Transition

NOTE: The minimum 3" (7.6 cm) clearance must exist between 
the top of the damper assembly and the rectangular to round 
transition piece so that the damper can open freely and fully.

Recommended Standard Fittings

The following length equivalents are for use when figuring vent 
length. See the examples in “Recommended Vent Length.”

Recommended Vent Length

A 3

¹⁄₄

"

 x 10

"

 (8.3 x 25.4 cm) rectangular or 6

"

 (15.2 cm) round vent 

should be used.
The total length of the vent system including straight vent, 
elbow(s), transitions and wall or roof caps must not exceed the 
equivalent of 140 ft (42.7 m) for either type of vent. See 
“Recommended Standard Fittings” section for equivalent lengths.
For best performance, use no more than three 90° elbows.
To calculate the length of the system you need, add the equivalent 
lengths of each vent piece used in the system. See the following 
examples:

3

¹⁄₄

" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total

6" (15.2 cm) vent system = 73 ft (22.2 m) total

If the existing vent is round, a rectangular to round transition piece 
must be used. In addition, a rectangular 3" (7.6 cm) extension vent 
between the damper assembly and rectangular to round transition 
piece must be installed to keep the damper from sticking.

A. Roof cap
B. 6" (15.2 cm) min. diameter round vent

C. Elbow (for wall venting only)
D. Wall cap

E. 3

¹⁄₄

" x 10" to 6" (8.3 x 25.4 cm to 15.2 cm) 

rectangular to round transition piece

F. Vent extension piece, at least 3" (7.6 cm) high

A. Rectangular to round transition piece: 3

¹⁄₄

" x 10" to 6" = 5 ft

(8.3 x 25.4 cm to 15.2 cm = 1.5 m)

B. Roof cap: 3

¹⁄₄

" x 10" = 24 ft (8.3 x 25.4 cm = 7.3 m)

C. 90° elbow: 3

¹₄

" x 10" = 25 ft (8.3 x 25.4 cm = 7.6 m)

D. 90° elbow: 6" = 10 ft (15.2 cm = 3 m)

E. Wall cap: 3

¹⁄₄

" x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m)

F. 45° elbow: 6" = 5 ft (15.2 cm = 1.5 m)

G. 90° flat elbow: 3

¹⁄₄

" x 10" = 10 ft (8.3 x 25.4 cm = 3 m)

A

B

C

E

F

D

3" (7.6 cm)

A                           B                            C

D                  E                    F               G

A. One 3

¹⁄₄

" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)

B. 1 wall cap = 40 ft (12.2 m)

C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)

A. Two 90° elbows = 20 ft (6.1 m)
B. 1 wall cap = 40 ft (12.2 m)

C. 1 rectangular to round transition piece = 5 ft (1.5 m)
D. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)

A                                          B

C

6 ft (1.8 m)

2 ft

(0.6 m)

A                                                                  B

C                                  D

6 ft (1.8 m)

2 ft

(0.6 m)

Summary of Contents for YUMV4084BS0

Page 1: ...eau de remplissage en acier inoxydable non fourni ou d un élément de placard personnalisé Voir la section Achever l installation Table of Contents Table des matières MICROWAVE HOOD COMBINATION SAFETY 2 INSTALLATION REQUIREMENTS 2 Tools and Parts 2 Location Requirements 3 Product Dimensions 3 Electrical Requirements 4 Venting Requirements 4 INSTALLATION INSTRUCTIONS 6 Install L Brackets 6 Prepare U...

Page 2: ...duce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety me...

Page 3: ...illustration in Venting Requirements section Some cabinet and building materials are not designed to withstand the heat produced by the microwave oven for cooking Check with your builder or cabinet supplier to make sure that the materials used will not discolor delaminate or sustain other damages Installation Dimensions NOTE The grounded 3 prong outlet must be inside the upper cabinet See Electric...

Page 4: ...system using caulking compound to seal exterior wall or roof opening around cap for optimal hood performance do not install 2 elbows together If rectangular to round transition is used be sure there is at least 3 7 6 cm of clearance between the top of the damper assembly and the transition piece See Rectangular to Round Transition illustration Electrical Shock Hazard Plug into a grounded 3 prong o...

Page 5: ...2 2 m total If the existing vent is round a rectangular to round transition piece must be used In addition a rectangular 3 7 6 cm extension vent between the damper assembly and rectangular to round transition piece must be installed to keep the damper from sticking A Roof cap B 6 15 2 cm min diameter round vent C Elbow for wall venting only D Wall cap E 3 x 10 to 6 8 3 x 25 4 cm to 15 2 cm rectang...

Page 6: ...er Cabinet 1 Find the centerline of the installation space Mark the centerline on the bottom of the upper cabinet 2 Measure and mark the power cord and vent holes as shown making sure they are centered on the centerline 3 Cut the power cord hole using the 1 3 8 cm hole drill bit 4 Cut 3 4 19 mm hole at one corner of the vent hole marking 5 Using a keyhole saw cut out the rectangular vent area Inst...

Page 7: ...head bolt then install each bolt through the L bracket base slot into the mounting hole in the bottom of the microwave oven Do not overtighten Install Damper Assembly 1 Insert damper assembly through the upper cabinet cutout and orient it so that the 3 mounting holes are toward the back of the microwave oven 2 Secure the damper assembly to the upper component housing with five 9 5 mm metal screws ...

Page 8: ...holes Install Rear Trim 1 Measure the distance from the rear wall to the front edge of the rear frame of the bottom plate 2 Cut the rear trim to the same measurement 3 Peel off adhesive strip covers and place the rear trim against the rear wall and microwave oven bottom NOTE Make sure trim does not cover the opening for grease filter A Opening for grease filter 4 Secure rear trim with three 9 5 mm...

Page 9: ...e of the grease filter with the charcoal filter 2 Insert wire rods to hold charcoal filter in place 3 Install grease filter See Install Grease Filter section Install Grease Filter 1 Place bracket end of the grease filter into one side of the bottom plate opening push toward the bracket end and swing up the tabbed end of the grease filter 2 Push the tabbed end of the grease filter up until the tabs...

Page 10: ...n Check that the power supply cord is plugged into a grounded 3 prong outlet See the Use and Care Guide for troubleshooting information Installation is now complete Save Installation Instructions for future use NOTE After installation is complete the upper component housing on the top of the microwave oven will be visible Figure 1 The housing may be covered using a stainless steel panel kit Figure...

Page 11: ... the installation hardware needs to be replaced call us at our toll free number listed in the Use and Care Guide Following is a list of available replacement parts You will need your model number located on the front facing of the microwave oven opening behind the door Damper Assembly Visor Rear Trim Mounting Screw Kit includes parts G M in Parts Supplied in the Tools and Parts section L brackets ...

Page 12: ...W10589884A 2013 Used under license in Canada All rights reserved Utilisé sous licence au Canada Tous droits réservés 6 13 Printed in Sweden Imprimé en Suède ...