background image

Summary of Contents for YSF379LEMB0

Page 1: ...quirements Gas supply requirements Product dimensions Cabinet dimensions requirements Installation steps Gas conversions if range does not operate if you need assistance service Moving the range iMPORTANT Read and save these instructions iMPORTANT Installer Leave Installation Instructions with the homeowner Homeowner Keep Installation Instructions for future reference Read and save these instructi...

Page 2: ...FPA 70 latest edition or CSA Standard C22 1 Canadian Electrical Code Part 1 latest edition and all local codes and ordinances Proper installation is your responsibility A qualified technician must install this range Make sure you have everything necessary for correct installation It is the installer s responsibility to comply with installation clearances specified on the gas information label The ...

Page 3: ... gas pipe Check with a qualified electrician if you are not sure range is properly grounded A 120 volt 60 Hz AC only 10 ampere fused electrical supply is required A time delay fuse or circuit breaker is recommended It is recommended that a separate circuit serving only this appliance be provided Electronic ignition systems operate within wide voltage limits but proper grounding and polarity are ne...

Page 4: ...mum A smaller size pipe on longer runs may result in insufficient gas supply Usually LR gas suppliers determine the size and materials used in the system Pipe joint compounds made for use with L R gas must be used on pipe threads only Flexible metal appliance connector If local codes permit a new AGA or CSA design certified 1 2 or 3 4 I D flexible metal appliance connector is recommended for conne...

Page 5: ... requirements 27 1 8 68 9 cm J depth with handle 25 63 5 cm 29 7 8 75 9 cm width il 36 91 4cm cooktop height 46 7 8 119 1 era overall height Cabinet dimensions requirements J Anti tip bracket The floor mounted anti tip bracket must be installed To install the anti tip bracket supplied see page 3 and the anti tip bracket template instruction sheet ...

Page 6: ... Longer screws are available from your local hardware store Operating position Remove cardboard shipping base from under range Remove storage drawer Use a 3 8 drive ratchet to lower rear leveling legs one half turn Use channel lock pliers to lower front leveling legs one half turn Before moving range across floor check that range is still on cardboard shipping base to protect floor covering rear l...

Page 7: ... 3 4 pressure regulator gas pipe female pipe threads Om Use 5 16 combination wrench and channel lock pliers to attach the flexible connector to the adapters Check that connector is not kinked 1 Check that range regulator shutoff valve is in the on position Open the manual shutoff valve in the gas supply line regulator shutoff valve in on position manual shutoff valve in open position to range gas ...

Page 8: ...crewdriver into the valve stem Turn the valve screw to obtain the smallest flame that will not go out when the control of a cold burner is quickly turned from HIGH to LOW Repeat for other cooktop burners as needed Check operation of oven burner Open oven door Remove oven bottom Remove two screws at the rear of the oven bottom Lift the rear of the oven bottom up and back until the front of the pane...

Page 9: ...FF or press the OFF CANCEL pad Replace flame spreader oven bottom and oven racks Check operation of oven broil burner Follow the instructions for your type of oven controls NOTE A faint ticking sound will be heard while the oven burner lights The oven burner should light within 8 seconds if your range has an oven temperature control knob Push in and turn the oven selector control knob to BROIL Ift...

Page 10: ... Green front Blue Right 8 000 LS0 Green front Lt Blue Right 5 000 L65 Green rear Brown A brass orifice spud is located in the center of each burner throat about 2 5 cm below the cooktop Apply masking tape to the end of a 5 16 nut driver to fit snugly over the orifice spud Press driver down onto the spud of the left front burner and remove by turning spud counter clockwise and lifting it out Replac...

Page 11: ... spark electrode orifice spud holder range cooktop Locate the Natural gas orifice spuds on the spud card on the back of the range Orifice spuds are stamped with a number and marked with two color dots Natural gas orifice spud Natural Gas Surface Propane rate Orifice burner Left rear Left front Right front Right rear BTU hr 9 500 13 500 9 500 5 000 Number N151 N186 N151 Nl12 Color Marking Blue Bras...

Page 12: ...your Use and Care Guide When you call you will need The range model number The range serial number Both numbers are listed on the model serial rating plate located on the oven frame behind the storage drawer Moving the range Tip Over Hazard A child or adult can tip the range and be killed Connect anti tip bracket to rear range foot Reconnect the anti tip bracket if the range is moved Failure to fo...

Reviews: