7
CONTROLS & ELECTRONICS
CONFIGURATION
Product Configuration
No frost Dlx
Product Control
RC Controlled
Software BEE/Pot
based
Professional
User interface
No
Auto cool mode
No
Ice accelerator
No
Auto Power save mode
No
Door Alarm
Yes
Power supply for illumination
DC (Linear 220mA)
RC Illumination (8 LED)
Yes
FC Illumination (2 LED)
Yes
Control Board
Yes(Nilgiri BEE)
Defrost heater
Yes (Integrated Al tube
275W)
Fan motor
10.5W MI Shaded Pole AC
fan motor
FC Door grounding
No
Compressor EMY65HLC
Run Capacitor
No
Door Reversibility
YES
RATED VOLTAGE : 220-240V,50-60Hz, IPH
VOLTAGE RANGE : 198V – 255V
INPUT WATTAGE : 112W
DEFROST WATTAGE : 275W
FULL LOAD AMPS : 0.5A
Summary of Contents for WRIT41N