ELECTRICAL CONNECTION

IMPORTANT: the data relevant to the voltage and power absorption are indicated on the rating plate.

ASSEMBLY

ADJUSTMENT TO DIFFERENT TYPES OF GAS

If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and information label 
on the top of the hob, change the injectors.
Remove the information label and keep it with the instructions booklet.

Use pressure regulators suitable for the gas pressure indicated in the Instruction.

The gas injector must be changed by After Sales Service or a qualified technician.

Injector not supplied with the appliance must be ordered from After Sales Service.

Adjust the minimum setting of the taps.

NOTE: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will go.
IMPORTANT: should you experience difficulty in turning the burners knobs, please contact the After Sales Service for 
the replacement of the burner tap if found to be faulty.
IMPORTANT: when gas cylinder is adopted, the gas cylinder or gas container must be properly settled (vertical orientation).

REPLACING THE INJECTORS (see the injector table in the Instruction)

ADJUSTING MINIMUM GAS SETTING OF TAPS

REFERENCE TO LOCAL REGULATIONS

Provision for ventilation

The room in which the appliance is installed must have an air supply to current 

B.S. 5440 - Part 2

.

All rooms require a permanent vent in addition to the openable window.
If there are other fuel burning appliances in the same room 

B.S. 5440 - Part 2

 should be consulted to determine the air vent 

requirements. If the appliance is installed in a cellar or basement, it is advisable to provide an air vent of 65 cm, irrespective of 
the room volume.

Gas Safety Regulations

The law requires that all gas appliances are installed by competent persons in accordance with the current gas safety 
regulations. Failure to install appliances correctly may lead to prosecution.
It is in your own interest, and that of safety, to ensure that the law is complied with. The hob should be installed in 
accordance with the 

Gas Safety (Installation and Use) Regulations

, the 

Building Regulations 

issued by the Department 

of the Environment and the

 Building Standard (Scotland) (Consolidation) Regulations

, issued by the Scottish 

Development Department. In the G.B., 

CORGI

 registered installers work to safe standards of practice.

Connection to gas supply

Before connecting the appliance, make sure that the gas supply system complies with standards 

UNI-CIG 7129 

and 

UNI CIG 7131

.

Gas connection

The connection to the mains gas network or gas cylinder must be made using a rigid copper or steel pipe with fittings complying 
with standards 

UNI-CIG 7129

, or using a continuous-surface stainless steel hose complying with standards 

UNI EN 148001

.

The maximum length of the hose is 2 m. The pressure control valves to be used must comply with the 

UNI EN 16129

 standard 

for gas cylinders and the 

UNI EN 88-1

 standard for piped methane gas.

Ensure that the installation and gas/electrical connections are performed by a qualified technician, following the
manufacturer's instructions and in compliance with current local safety regulations. 

 WARNING

This operation must be performed by a qualified technician.

 WARNING

The electrical connections must comply 
with local regulations.

The earthing of this appliance is 
compulsory by law.

Do not use an extension cord.

After having cleaned the perimeter surface, 
apply the supplied gasket to the hob as shown 
in the figure.

Position the hob in the worktop opening made respecting the dimensions indicated in the Instruction.

NOTE: the power supply cable must be long enough to permit its upward extraction.

To secure the hob, use the brackets (

A

) provided with it. Fit the brackets into the relevant bores shown by the arrow and 

fasten them by means of their screws in accordance with the thickness of the worktop (see the following figures). 

 WARNING

This operation must be performed by a qualified technician.

L

N

Earth

(yellow/green)

20

30

60

40

Top 20 mm

Top 40 mm

Top 30 mm

Top 60 mm

NO

Remove grids (

A

).

Extract  burners  (

B

).

Using a socket spanner of the appropriate size unscrew 
the injector (

C

), unscrew the injector to be replaced.

Replace it with the injector suitable for the new type of 
gas.

Re-assemble the injector in (

D

).

If you have a multiple crown burner use side spanner to 
replace the injector (

E

).

Before installing the hob, remember to affix the gas 
calibration plate supplied with the injectors in such a way 
that it covers the existing information relating to gas 
calibration.

To ensure that the minimum setting is correctly adjusted, remove the knob and 
proceed as follows:

tighten screw to reduce the flame height (-);

loosen screw to increase the flame height (+).

The adjustment must be performed with the tap in minimum gas setting position (small 
flame) .

The primary air of the burners does not need to be adjusted.

At this stage, light up the burners and turn the knobs from max position   to 

minimum position   to check flame stability.

Upon completion of adjustment, reseal using sealing wax or an equivalent material.

PT

Summary of Contents for WHGOF7523SB

Page 1: ...he appliance surface do not use the appliance After unpacking the hob make sure that it has not been damaged during transport In the event of problems contact the dealer or your nearest After sales Service TECHNICAL INFORMATION FOR THE INSTALLER Use protective gloves for handling preparing and installing the product This product can be embedded in a worktop 20 to 60 mm thick If there is no oven be...

Page 2: ...the gas supply system complies with standards UNI CIG 7129 and UNI CIG 7131 Gas connection The connection to the mains gas network or gas cylinder must be made using a rigid copper or steel pipe with fittings complying with standards UNI CIG 7129 or using a continuous surface stainless steel hose complying with standards UNI EN 148001 The maximum length of the hose is 2 m The pressure control valv...

Page 3: ...ges in appearance can be noticed in the uncoated bottom surface of the burners or either after several cleaning cycles on the black coated surface These esthetical changing though do not impact product quality neither its performances CLEANING THE HOB PARTS Clean glass and enamelled parts only with soft cloth or sponge Grids burner caps and burners can be removed to be cleaned Clean them by hand w...

Page 4: ...se of the grids can result in damage to the hob do not position the grids upside down or slide them across the hob Do not use Cast iron griddles ollar stones terracotta pots and pans Heat diffusers such as metal mesh or any other types Two burners simultaneously for one receptacle e g fish kettle Liquids spilled on hot hob area can cause glass damage Burner Pot Ø Rapid From 24 to 26 cm Semi rapid ...

Reviews: