Location Requirements
IMPORTANT:
Observe all governing codes and ordinances.
Do not obstruct flow of combustion and ventilation air.
n
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located on the left side of the
bottom of the broiler.
A. Model/serial rating plate location
n
The range should be located for convenient use in the
kitchen.
n
Recessed installations must provide complete enclosure of
the sides and rear of the range.
n
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
n
All openings in the wall or floor where range is to be installed
must be sealed.
n
Do not seal the range to the side cabinets.
n
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
n
The anti-tip bracket must be installed. To install the anti-tip
bracket shipped with the range, see “Install Anti-Tip Bracket”
section.
n
Grounded electrical supply is required. See “Electrical
Requirements” section.
n
Proper gas supply connection must be available. See “Gas
Supply Requirements” section.
n
Contact a qualified floor covering installer to check that the
floor covering can withstand at least 200°F (93°C).
n
Use an insulated pad or 1/4" (6.4 mm) plywood under range
if installing range over carpeting.
IMPORTANT:
To avoid damage to your cabinets, check with
your builder or cabinet supplier to make sure that the materials
used will not discolor, delaminate, or sustain other damage. This
oven has been designed in accordance with the requirements
of UL and CSA International and complies with the maximum
allowable wood cabinet temperatures of 194°F (90°C).
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD Part 280). When such
standard is not applicable, use the Standard for Manufactured
Home Installations, ANSI A225.1/NFPA 501A, or with local
codes.
Mobile home installations require:
n
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the
standards listed above.
Product Dimensions
A. 36" (91.4 cm)
B. 29
7
⁄
8
" (75.9 cm)
C. 25
7
⁄
64
" (63.8 cm)
D. 47
5
⁄
64
" (119.6 cm)
A
D
C
B
A