21
Wiring Connection Diagram - Honeywell
®
SmartValve II
®
Ignition System
Check codes for proper wiring and circuit protection before
installation.
NOTES:
1. If any of the original wire as supplied with the furnace must be
replaced, it must be replaced with wiring material having a
temperature rating of at least 90°C.
2. Not used on all models
3. For a fixed blower off delay of 90 seconds see “Blower
Control Board” section. Jumper can be cut for a 150 second
off delay.
INDUCED
DRAFT
BLOWER
INTERLOCK
SWITCH
CIRCULATION
BLOWER
CONDENSER
THERMOSTAT & SUB-BASE
HEAT ANTICIPATOR
.75 AMP
LINE VOLTAGE - FACTORY
LINE VOLTAGE - FIELD
LOW VOLTAGE - FACTORY
LOW VOLTAGE - FIELD
HONEYWELL
DELAY OFF SWITCH SETTINGS
60 SEC
90 SEC
120 SEC
150 SEC
SEE NOTE 2
FIG. 1
SEE NOTE 3
JUMPER
R
C
W
Y
G
BLOWER
CONTROL
TWIN
24V
A
C
M1
HUM
COM
NEUTRAL
CONT COOL
M2
HEA
T
EA
C
SEE NO
TE 2
12
4
1
5
2
6
3
BLK
ORG
BLU
RED
HUM
EAC
SEE NOTE 2
WHT (NEUT)
RED (LO)
ORN (MED/LO)
BLU (MED)
TRANSFORMER
YEL
YEL
WHT
WHT
WHT
WHT
BLK
BLK
120/1/60
FLAME
SENSOR
HOT SURFACE
IGNITER
S2
P2
SMARTVALVE
IGNITION
CONTROL
YEL
YEL
C3
C2
BLK
4
3
1
2
4
3
2
1
BLU
RED
ORG
5
1
2
6
7
3
4
8
C1
S1
P1
BLK/WHT
VLT
VLT
BRN
BRN
ROLLOUT
SWITCH
PRESSURE
SWITCH
AUX
LIMIT
AUX
(IF USED)
ROLLOUT
SWITCH
WHT
WHT
WHT
VLT
HIGH
LIMIT
WHT/BLK
GRN
WHT
GRY
WHT
1 2
2
1
2 1
2
1
YEL (MED/HI)
NOT USED ON ALL MODELS
*
(IF USED)
LIMIT
(IF USED)
BLK (HIGH)
*
or
BLU
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.