background image

29" Electric Dryer

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

WED4750X, WED4800X, WED4900X, 
WED4850X, WED4890X, WED4910X

Electrical

This dryer requires a 3 or 4 wire, single 

phase, 120/240 volt, 60 Hz., AC only electrical 

supply (or 3 or 4 wire, 120/208 volt electrical supply, 

if specified on the serial/rating plate) on a separate 

30-amp circuit, fused on both sides of the line. A time-

delay fuse or circuit breaker is recommended. Connect 

to an individual branch circuit. Do not have a fuse in the 

neutral or grounding circuit.

Water

 

(Steam models only)

The dryer must be  

connected to the cold water faucet using new inlet 

hoses. Do not use old hoses. Do not overtighten.  

Damage to the coupling can result.

Exhaust venting

Exhaust your dryer to the outside. 

4" (102 mm) diameter vent is required. Rigid or flexible 

metal exhaust vent must be used. Do not use plastic  

or metal foil vet. Exhaust hood must be at least  

12" (305 mm) from the ground or any object that  

may be in the path of the exhaust.

Hood styles: A & B are recommended.

   

4"

(102 mm)

2½"

(64 mm)

     

4"

(102 mm)

      

4"

(102 mm)

B

A

A. Louvered hood  
B. Box hood 
C. Angled hood (acceptable) 

C

Dryer dimensions

Select the route that will provide the straightest and most direct path outdoors.  

 

Plan the installation to use the fewest number of elbows and turns.  

 

Use the fewest 90° turns possible.

Because Whirlpool Corporation policy includes a continuous commitment to improve 

Dimensions are for planning purposes only. For complete details, see Installation 

our products, we reserve the right to change materials and specifications without notice. 

Instructions packed with product. Specifications subject to change without notice.

W10096987 

06/2011

For closet installation, with a door, the minimum ventilation openings in the top  

and bottom of the door are required. Louvered doors with equivalent air ventilation  

openings are acceptable.

Do not use vent runs longer than specified in vent 

length chart.  

 

Determine the number of elbows you will need.

Most installations require a minimum 5½" (140 mm) clearance   

 behind the dryer for the exhaust vent with elbow. See “Venting  

 Requirements.”

Vent system chart

Number of 

90° elbows

Type  

of vent

Box/louvered

hoods

Angled  

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

58 ft. (17.7 m)

48 ft. (14.6 m)

38 ft. (11.6 m)

29 ft. (8.8 m)

21 ft. (6.4 m)

The Vent system chart provides venting requirements 

that will help achieve best drying performance.

NOTE:

 Side and bottom exhaust installation have a 90° 

turn inside the dryer. To determine maximum exhaust 

length, add a 90° turn to the total number of elbows 

when referemcing the chart.

Minimum Required Spacing

A. Large opening side-swing door

B. Large opening side-swing door

C. Wide opening side-swing door

D. Wide opening hamper door

 

A

B

C

    18"*

(457 mm)

  1"

(25 mm)

29"

(737 mm)

        1"

   (25 mm)

        1"*

    (25 mm)

14" max.*

(356  mm)

   

27

¾"

(705 mm)

  48 in.

  

(310 cm )

2

*

2

       3"*

(76 mm)

       3"*

(76 mm)

  

24 in.

(155 cm )

*

2

A. Recessed area

B. Side view - closet or confined area

C. Closet door with vents

Reviews: