Page 1: ...ided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean You can be killed or seriously injured if you don t immediatel...

Page 2: ...nections be made by a licensed qualified electrical installer IMPORTANT Observe all governing codes and ordinances It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located below the electronic control on oven frame To eliminate the risk of burns or fire by reaching over heated surface units cabin...

Page 3: ... 61 cm base cabinet Cabinet Dimensions Cabinet opening dimensions shown are for 25 64 cm countertop depth 24 61 cm base cabinet depth and 36 91 4 cm countertop height IMPORTANT If installing a range hood or microwave hood combination above the range follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface 1 I I H A 13 33 cm ...

Page 4: ... wire to the ends of the flexible conduit leads 2 Connect the aluminum wiring to the added section of copper wire using special connectors and or tools designed and UL listed for joining copper to aluminum Follow the electrical connector manufacturer s recommended procedure Aluminum copper connection must conform with local codes and industry accepted wiring practices The cooktop sides of the drop...

Page 5: ...A Centerline B 133 4 34 9 cm 5 6 1 Drill two 3 0 mm holes that correspond to the bracket holes of the determined mounting method See the following illustrations Floor Mounting Wall Mounting A B _ S A 12 x 1 screws B Anti tip bracket A 12 x 1 screws B Anti tip bracket Using the Phillips screwdriver mount anti tip bracket to the support slat or the wall support board depending on the chosen method o...

Page 6: ...ding through neutral New Branch circuit installations 1996 NEC mobile homes recreational vehicles and new construction D H I A Cable from home power supply B Black wires C Red wires D 4 wire flexible conduit from range E Junction box F White wires G UL listed wire connectors H Green or bare ground wires I UL listed or CSA approved conduit connector 1 Connect the 2 black wires B together using a UL...

Page 7: ...veling leg is engaged in anti tip bracket NOTE Range must be level for satisfactory baking conditions J t t A A Screws B Lower trim piece C o np ns t 1 Check that all parts are now installed If there is an extra part go back through the steps to see which step was skipped 2 Check that you have all of your tools 3 Dispose of recycle all packaging materials 4 Check that the range is level See the Le...

Page 8: ...ard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock 1 Disconnect power 2 Disconnect wiring 3 Slide range forward to complete cleaning or maintenance 4 Check that the anti tip bracket is installed and engaged See the Verify Anti Tip Bracket Is Installed and Engaged section When moving range use 2 or more people...