ASSISTANCE OR SERVICE

When calling for assistance or service, please know the purchase 
date and the complete model and serial number of your 
appliance. This information will help us to better respond to your 
request.

If you need replacement parts

If you need to order replacement parts, we recommend that you 
use only factory specified parts. Factory specified parts will fit 
right and work right because they are made with the same 
precision used to build every new appliance. To locate factory 
specified replacement parts in your area, call us or your nearest 
designated service center.

In the U.S.A.

Call the Whirlpool Customer eXperience Center 
toll free: 1-800-253-1301 or visit www.whirlpool.com.

Our consultants provide assistance with:

Features and specifications on our full line of appliances.

Installation information.

Use and maintenance procedures.

Accessory and repair parts sales.

Specialized customer assistance (Spanish speaking, hearing 
impaired, limited vision, etc.).

Referrals to local dealers, repair parts distributors and service 
companies. Whirlpool designated service technicians are 
trained to fulfill the product warranty and provide after-
warranty service, anywhere in the United States.

To locate the Whirlpool designated service company in your 
area, you can also look in your telephone directory Yellow 
Pages.

For further assistance

If you need further assistance, you can write to Whirlpool 
Corporation with any questions or concerns at:

Whirlpool Brand Home Appliances
Customer eXperience Center
553 Benson Road
Benton Harbor, MI 49022-2692

Please include a daytime phone number in your correspondence.

In Canada

Call the Whirlpool Canada LP Customer eXperience Centre toll 
free: 1-800-807-6777 or visit our webpage www.whirlpool.ca.

Our consultants provide assistance with:

Features and specifications on our full line of appliances.

Use and maintenance procedures.

Accessory and repair parts sales.

Referrals to local dealers, repair parts distributors, and 
service companies. Whirlpool Canada LP designated service 
technicians are trained to fulfill the product warranty and 
provide after-warranty service, anywhere in Canada. 

For further assistance

If you need further assistance, you can write to Whirlpool 
Canada LP with any questions or concerns at:

Customer eXperience Centre
Whirlpool Canada LP
200 - 6750 Century Ave.
Mississauga, Ontario L5N 0B7

Please include a daytime phone number in your correspondence.

Accessories

Stainless Steel Cleaner and Polish

Order Part Number 31462A

Charcoal Filter Kit

Order Part Number W10355450

Power Cord Kit

Order Part Number W10355452

7" (17.8 cm) Round Damper

Order Part Number W10355451

7" (17.8 cm) Round Vent Mounting Plate

Order Part Number W10388168

Summary of Contents for UXT4230AD

Page 1: ...lpool ca HOTTE D ASPIRATION DE 30 76 2 CM ET 36 91 4 CM Instructionsd installationetGuided utilisationetd entretien Au Canada pour assistance installation ou service composer le 1 800 807 6777 ou visiter notre site Web à www whirlpool ca Table of Contents Table des matières 2 IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY IMPORTANT LIRE ET CONSERVER CES INSTRUCTIONS POUR UTILI...

Page 2: ...r l installation 29 UTILISATION DE LA HOTTE 29 Commandes de la hotte de cuisinière 29 ENTRETIEN DE LA HOTTE 29 Nettoyage 29 SCHÉMA DE CÂBLAGE 31 ASSISTANCE OU SERVICE 32 Au Canada 32 Accessoires 32 GARANTIE 33 RANGE HOOD SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potent...

Page 3: ...ical wiring and other utilities Ducted fans must always be vented outdoors CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or into crawl spaces or garages WARNING TO REDUCE THE RISK OF F...

Page 4: ...l filter kit For information on ordering see the Accessories section LocationRequirements IMPORTANT Observe all governing codes and ordinances It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located inside the range hood on the left wall Range hood location should be away from strong draft areas...

Page 5: ...mper should be on the cold air side of the thermal break The break should be as close as possible to where the vent system enters the heated portion of the house Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement The specified CFM varies from locale to locale Consult your HVAC professional for specific...

Page 6: ...8 cm 90 elbow 5 0 ft 1 5 m Maximum Recommended Length 50 ft 15 2 m 1 90 elbow 5 0 ft 1 5 m 1 wall cap 0 0 ft 0 0 m 8 ft 2 4 m straight 8 0 ft 2 4 m Length of 7 17 8 cm system 13 0 ft 3 9 m Wall cap 7 17 8 cm round 90 elbow 2 ft 0 6 m 6 ft 1 8 m Vent Piece 3 x 10 8 3 cm x 25 4 cm 90 elbow 5 0 ft 1 5 m 3 x 10 8 3 cm x 25 4 cm flat elbow 12 0 ft 3 7 m 3 x 10 8 3 cm x 25 4 cm wall cap 0 0 ft 0 0 m Max...

Page 7: ...g practices Wire sizes and connections must conform with the rating of the appliance as specified on the model serial rating plate The model serial plate is located behind the filter on the rear wall of the range hood Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 l...

Page 8: ... 9 8 cm down from underside of cabinet and mark on the centerline on the back wall 2 Mark lines 5 13 3 cm to the right and left of the centerline on the wall 3 Use saber or keyhole saw to cut a rectangular opening in the wall for the vent Style 2 Cut Openings for 3 x 10 8 3 x 25 4 cm Rectangular Vent to Round Vent Transition Roof Venting To make a 4 x 10 10 8 cm x 26 7 cm rectangular cutout on the...

Page 9: ... Your model will have a 3 x 10 8 3 x 25 4 cm rectangular vent damper on the inside of the range hood 1 Remove the 3 x 10 8 3 x 25 4 cm rectangular vent damper attached with 3 5 x 9 5 mm screws on the inside your range hood Use these screws to install the rectangular vent damper 2 Lift the range hood up under cabinet and determine final location by centering beneath cabinet Mark on the underside of...

Page 10: ...round vent mounting plate and 3 x 10 8 3 x 25 4 cm rectangular vent damper can be installed up to 1 2 5 cm on either side of the hood center to accommodate off center ductwork If a vent damper is installed with a wall cap with damper check that they do not interfere with each other Remove the vent connector damper flap if they interfere Non vented recirculating installations No vent attachments Re...

Page 11: ...e only with range hood cord connection kits that have been investigated and found acceptable for use with this model range hood Do not reconnect power until the installation is complete 2 Remove the screw from the terminal box cover Remove terminal box cover and set aside 3 Remove the power supply knockout from the top or rear of the vent hood depending on the incoming location of your home power ...

Page 12: ...ction If range hood does not operate check to see whether a circuit breaker has tripped or a household fuse has blown Disconnect power and check wiring connections NOTE To get the most efficient use from your new range hood read the Range Hood Use section A White wires B Black wires C UL listed wire connector D Green or bare ground wire E Home power supply cable or power cord accessory kit F UL li...

Page 13: ...TANT Do not use soap filled scouring pads abrasive cleaners Cooktop Polishing Creme steel wool gritty washcloths or paper towels To avoid damage to the stainless steel do not use cleaners that contain chlorine Cleaning Method Rub in direction of grain to avoid scratching or damaging the surface For stainless steal models Stainless Steel Cleaner and Polish Part Number 31462A not included See Assist...

Page 14: ... Turn off the range hood and allow the light bulb to cool 1 Disconnect power 2 Squeeze the plastic lens cover and remove it from the hood 3 Screw light bulb into socket 4 Replace lens cover by squeezing cover and inserting tabs into slots 5 Reconnect power If new light does not operate make sure the lamp is inserted correctly before calling service WIRING DIAGRAM A Light bulb socket B Lens cover A...

Page 15: ...ny in your area you can also look in your telephone directory Yellow Pages For further assistance If you need further assistance you can write to Whirlpool Corporation with any questions or concerns at Whirlpool Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence InCanada Call the Whirlpool Canada...

Page 16: ...ble parts i e light bulbs batteries air or water filters preservation solutions etc 5 Conversion of products from natural gas or L P gas 6 Damage from accident misuse abuse fire floods acts of God or use with products not approved by Whirlpool 7 Repairs to parts or systems to correct product damage or defects caused by unauthorized service alteration or modification of the appliance 8 Cosmetic dam...

Page 17: ...plete model number and serial number You can find this information on the model and serial number label located on the product Dealer name____________________________________________________ Address ________________________________________________________ Phone number__________________________________________________ Model number __________________________________________________ Serial number ___...

Page 18: ...areil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d autres Tous les messages de sécurité suivront le symbole d alerte de sécurité et le mot DANGER ou AVERTISSEMENT Ces mots signifien...

Page 19: ...die et évacuer adéquatement les gaz veiller à acheminer l air aspiré par un conduit jusqu à l extérieur ne pas décharger l air aspiré dans un espace vide du bâtiment comme une cavité murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS MÉTALLIQUES AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR L...

Page 20: ...r des pièces voir la section Accessoires Exigencesd emplacement IMPORTANT Observer les dispositions de tous les codes et règlements en vigueur C est à l installateur qu incombe la responsabilité de respecter les distances de séparation exigées spécifiées sur la plaque signalétique de l appareil La plaque signalétique est située à l intérieur de la hotte sur la paroi de gauche Installer la hotte de...

Page 21: ... REMARQUE Si l on utilise un clapet anti reflux il est possible que la cuisinière ne réponde pas aux critères du document California Title 24 À l aide d un produit de calfeutrage assurer l étanchéité autour de la bouche de décharge à l extérieur à travers le mur ou le toit Installations dans les régions au climat froid On doit installer un clapet anti reflux supplémentaire à l arrière pour minimis...

Page 22: ...8 cm pour décharge à travers le toit achat séparé Conduit rectangulaire de 3 x 10 8 3 x 25 4 cm pour décharge à travers le toit achat séparé B Bouche de décharge sur toit avec clapet achat séparé C Entre 18 45 7 cm min et 24 61 cm max au dessus de la surface de cuisson A Conduit rond de dia 7 17 8 cm avec sortie par le dessus et décharge à travers le mur achat séparé Conduit rectangulaire de 3 x 1...

Page 23: ... 2 Connecter le câblage en aluminium à la section ajoutée de câblage en cuivre en utilisant des connecteurs et ou des outils spécialement conçus et homologués UL pour fixer le cuivre à l aluminium Appliquer la procédure recommandée par le fabricant des connecteurs électriques La connexion aluminium cuivre doit être conforme aux codes locaux et aux pratiques de câblage acceptées par l industrie Le ...

Page 24: ...e distance A à partir de la droite de l axe central sur la face inférieure du placard Sur cette ligne marquer le point situé à 2 5 1 cm du mur arrière Percer en ce point un trou de 1 3 2 cm de diamètre à travers le placard Passage du câble à travers le mur 1 Tracer une ligne de distance A à partir de la droite de l axe central sur la face inférieure du mur Marquer un point sur cette ligne qui se t...

Page 25: ... sur la face inférieure du sommet du placard 1 Tracer un axe central sur la face inférieure du sommet du placard 2 Tracer une ligne de 5 12 7 cm en partant du mur arrière sur la face inférieure du sommet du placard 3 Utiliser un compas ou un gabarit circulaire pour tracer un cercle avec un diamètre de 0 64 cm supérieur à celui du conduit d évacuation 4 Utiliser une scie sauteuse ou une scie à guic...

Page 26: ...otte à part sur une surface couverte 3 À l aide d un foret de 3 mm percer 4 avant trous tel qu illustré 4 Installer les 4 vis de montage 4 5 x 13 mm dans les avant trous Laisser un espace d environ 6 4 mm entre les têtes des vis et le placard pour faire glisser la hotte et la mettre en place 5 Selon le modèle ôter les opercules amovibles du conduit d évacuation Installations pour système d évacuat...

Page 27: ...du clapet anti retour 2 Faire glisser la tige de retenue d un côté pour la faire sortir de son guide sur le volet et de l embout en plastique du clapet anti retour 3 Soulever l extrémité de la tige de retenue et dégager cette dernière de l autre guide sur le volet et de l autre embout en plastique en la faisant glisser 4 Pousser le petit côté des embouts en plastique pour sortir ces derniers du lo...

Page 28: ...ers le mur pour engager la partie étroite des trous sur les vis de fixation Serrer les vis de montage en s assurant que les vis sont dans la partie étroite des trous de fixation des vis 6 Raccorder le circuit d évacuation à la hotte Assurer l étanchéité des jointures avec des brides pour conduits ou du ruban adhésif 7 Vérifier que les clapets anti reflux fonctionnent correctement Raccordementélect...

Page 29: ... droite à la position 2 pour placer la lumière au réglage d éclairage puissant Fonctionnement du ventilateur La vitesse du ventilateur est variable Tourner le commutateur du ventilateur vers la droite pour mettre le ventilateur en position de MARCHE Continuer de faire tourner le commutateur jusqu à la vitesse de ventilateur souhaitée Pour ÉTEINDRE le ventilateur tourner le commutateur de vitesse d...

Page 30: ...lacement du filtre 1 Ôter la vis de la patte de retenue du filtre à graisse 2 Faire pivoter la patte de retenue du filtre à graisse pour libérer le filtre 3 Réinstaller le filtre en plaçant le bord arrière dans la rainure à l arrière de la hotte Enfoncer le filtre faire pivoter la patte de retenue du filtre pour fixer le filtre à la hotte 4 Réinstaller la vis de la patte de retenue du filtre à gra...

Page 31: ...ble 1 2 Arrêt 1 L Élevé L Neu N BL R R BL REMARQUE Vitesse 1 non utilisée R N N R N BL N BL JA Diode redresseuse Vitesse 2 Commun Vitesse 1 1 2 10 A 73 10 Watts 17 1 10 Ohms 13 6 10 Ohms Caractéristiques du moteur Alimentation électrique 120 VCA Fréquence 60 Hz Intensité Puissance nominale Résistance du moteur Blanc Rouge Blanc Noir Vis de mise à la terre Terre ...

Page 32: ...ations sur toute notre gamme d appareils électroménagers Consignes d utilisation et d entretien Ventes d accessoires et de pièces de rechange Références aux marchands locaux aux distributeurs de pièces de rechange et aux compagnies de service Les techniciens de service désignés par Whirlpool Canada LP sont formés pour remplir la garantie des produits et fournir un service après la garantie partout...

Page 33: ...à eau solutions de conservation etc 5 Conversion de votre produit du gaz naturel ou du gaz de pétrole liquéfié 6 Dommages causés par accident mésusage abus incendie inondations catastrophe naturelle ou l utilisation de produits non approuvés par Whirlpool 7 Réparations aux pièces ou systèmes dans le but de rectifier un dommage ou des défauts résultant d une réparation altération ou modification no...

Page 34: ...o de série au complet Vous trouverez ces renseignements sur la plaque signalétique située sur le produit Nom du marchand ______________________________________________ Adresse ________________________________________________________ Numéro de téléphone ___________________________________________ Numéro de modèle______________________________________________ Numéro de série ________________________...

Reviews: