WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati
Failure description / repair Mistral I200
Troubleshooting
Component
Fault
Description
Service Action
COOKTOP
25
Fan blocked
1)
Visible check of the fun (some mechanical problem)
2)
Check Fan connection
– if the connector is plugged in
well or not.
3)
Replace the Fan with a new one.
4)
If replacing the fan with a new one did not fix the
appliance, then the old fan is still good. Put it back in
the appliance. Change the IPC.
IPC
34
Heatsink NTC shorted
1)
Change the IPC;
IPC
35
Heatsink NTC open
1)
Change the IPC;
BURNER
36
Coil1/2 NTC shorted
1)
Check if the NTC coil that is showing the failure is well
plugged in the proper connector.
2)
Replace the interested Coil with a new one.
3)
If replacing the Coil with a new one did not fix the
appliance, then the old coil is still good. Put it back in
the appliance. Change the IPC
BURNER
37
Coil1/2 NTC open or
Cold
1)
Verify if the room temperature is too low (<0°C)
2)
Check if the NTC coil that is showing the failure is well
plugged in the proper connector.
3)
Replace the interested Coil with a new one.
4)
If replacing the Coil with a new one did not fix the
appliance, then the old coil is still good. Put it back in
the appliance. Change the IPC