Page 1: ...re Guide for a toll free number to call or call the dealer from whom you purchased the cooktop when you Have questions about the cooktop installation or operation Need to obtain the name and number of an authorized service company The dealer is listed in the Yellow Pages of your phone directory under Appliances Household Major Service and Repair When you call you will need The cooktop model number...

Page 2: ...must conform to the Manufactured Home Construction and Safety Standards Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD part 280 or when such standard is not applicable the Standard for Manufactured Home Installations Manufactured Home Sites Communities and Setups ANSI A225 1 latest edition or with local codes Copies of the standards listed...

Page 3: ...ground prong Do not use an adapter Failure to follow these instructions can result in death fire or electrical shock If codes permit and a separate ground wire is used it isrecommended thata qualified electrician determine that the ground path is adequate Check with a qualified electrician if you are not sure whether the cooktop is properly grounded Do not ground to a gas pipe A 120 volt 60 Hz AC ...

Page 4: ...e must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1 2 psi 3 5 kPa Line pressuretesting at 1 2 psi gauge 14 WC or lower The downdraft cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of that system at test pressures equal to or less th...

Page 5: ...t 5 to 3 1 4 x 10 900 elbow _air flow this direction ___ not recommended _ air flow o 3 1 4 x 10 900 elbow air flow 6 to 3 1 4 x 10 _ air flow wall cap 3 1 4 x 10 5 or 6 round roof cap 10 x 10 thermal break _5 or 6 round Equivalent No of Total Length Pieces Equivalent Length Length 1 ft 30 5 cm 1 ft 30 5 cm 2 ft 61 cm 2 5 ft 76 cm 5 ft 152 cm 12 ft 366 cm 5ft 152 cm 1 ft 30 5 cm 9ft 274 cm 4 5 ft ...

Page 6: ...e the building Gas connection IMPORTANT All connections must be wrench tightened Do Not make connections to the gas regulator too tight Making the connection too tight may crack the regulator and cause a gas leak Do Not allow the regulator to turn on the pipe when tightening fittings All connections must be wrench tightened Assemble the flexible connector from the gas supply pipe to the pressure r...

Page 7: ...t go out Turn control knob to OFF position Repeat if necessary for other surface burner Check operation of left side surface burners or optional grill module Use module instructions to install left side surface burner or optional grill module Surface burners module Push in and turn right surface burner control knob to LITE position The flame should light within 4 seconds Turn the control knob to H...

Page 8: ...TOR Turn cap on top of pressure regulator counterclockwise with a wrench to remove cap Pull upward on edges of disk with your fingers to remove pin from cap Turn pin over so disk end is down Squeeze pin and snap it into place on cap Reinstall cap on pressure regulator front of unit Page 7 Remove Natural gas orifice hoods by turning hoods counterclockwise with 1 2 open end wrench Locate color coded...

Page 9: ...se fuse blown Check that the power supply cord is plugged into the wall receptacle Check that the gas supply valves are turned to the ON position See Use and Care Guide for troubleshooting list If you need assistance Check your Use and Care Guide for a toll free number to call or call the dealer from whom you purchased this appliance The dealer is listed in the Yellow Pages of your phone directory...