background image

Summary of Contents for RH8300XLS SERIES

Page 1: ... duct sizing Improper duct sizing or installation of restrictive roof jacks can reduce air moving capacity and provide inadequate ventilation for an indoor electric grill For most efficient smoke removal the top of the hood should be approximately 66 inches 167 6 cm from the floor MOTOR LIGHTS FILTER TOOLS AND MATERIALS REQUIRED l Drill electnc or ratchet drive with l d wood bit to dnll an access ...

Page 2: ...he hood into position simultaneously feeding the electrical wire through the knockout Follow applicable local codes and or latest National Electrical Code for electrical conector to be used at field wiring entrance 13 Tighten screws to secure hood Be sure screw head is in narrow neck of keyhole slot 14 Install proper duct work See page 4 15 Complete electrical wiring in junction box according to t...

Page 3: ...vertical discharge 2 From the blower position shown in Figure 7 lift the Blower Assembly vertically into mounting position 3 The 3 blower discharge surface should now be flush against top of hood This will allow proper air flow from the blower through the top vent The wider 5 surface will be to the rear FIGURE 7 VERTICAL DISCHARGE HORIZONTAL DISCHARGE 1 Figure 8 shows the proper Blower Assembly or...

Page 4: ...d the roof rain cap has 113 in2 free area choose the duct size required The 45i elbow can be approximated by dividing the equivalent duct lengths in Table2 by two Since we already have 9 ft of straight duct Tdble 1 tells us that 7 dia is too small So we try 8 dia 9 ft Straight Duct 6 ft Equivalent straight length of 45Oelbow 8 Dia 15 ft Fifteen feat is over the maximum of 13 ft for 8 dia duct so 8...

Page 5: ...its lasting beauty Clean with a mil detergent 00 NOT use abrasive cleaner for most effective removal of smoke and odors turn on fan a beginning of cooking operation and allow to run until smoke and odors are removed from the room If you need service or assistance we suggest you follow these four steps 2 It you 004 aadstaacc Call tha WhHpool COOL LINE sewice assistance lckphone mnnm Dhl ha from Con...

Reviews: