3-wire connection: Power supply cord

Use this method only if local codes permit connecting cabinet-
ground conductor to neutral wire of power supply cord.

1. Use a ¼" nut driver and remove the hex washer head screws 

from the aluminum terminal blocks.

2. Connect the neutral (center) wire to the center terminal 

connector using one of the hex washer head screws. 
Securely tighten screw for proper electrical connection.

3. Connect the other 2 wires (lines 1 and 2) to the outer terminal 

screws on the terminal block.

4. Tighten strain relief screws.

5. Replace terminal block cover.

Direct Wire Installation: Copper or Aluminum Wire

This range may be connected directly to the fuse disconnect or 
circuit breaker box. Depending on your electrical supply, make 
the required 3-wire or 4-wire connection.

1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip 

the insulation back 1" (2.5 cm) from the end of each wire.

2. Allow enough slack in the wire to easily attach the wiring 

terminal block.

3. Complete electrical connection according to your type 

electrical supply (4-wire or 3-wire electrical connection).

4-wire connection: Direct wire

Use this method for:

New branch-circuit installations (1996 NEC)

Mobile homes 

Recreational vehicles

In an area where local codes prohibit grounding through the 
neutral

1. Remove the ground-link screw from the range frame. Save 

the ground-link screw and cup washer. Bend the ground-link 
away from the range so that it does not contact the range.

2. Connect the bare ground wire to the range using the ground-

link screw and cup washer. The ground wire must be 
attached first and must not contact any other terminal.

3. Loosen (do not remove) the hex washer head screw and 

insert the neutral (white) wire under the screw clamp at the 
bottom of the center position terminal connector.

4. Insert the other 2 wires (lines 1 and 2) under the other 2 screw 

clamps.

5. Securely tighten the hex washer head screws to 

35 lbs-in. (4.0 N-m) minimum torque to make proper 
electrical connection.

6. Tighten the locking ring of the conduit connector.

7. Replace the terminal block cover.

A. Line 1
B. Ground-link

C. Hex washer head screw
D. Silver-colored terminal 

block screw

E. Neutral (center) wire

F. Line 2

G. UL listed strain relief 

and 40- or 50-amp range 
power supply cord

A

B

C

D

E

F

G

3"

(7.6 cm)

1"

(2.5 cm)

A. Ground-link  screw
B. Cup washer

C. Ground-link bent away from range

A. Bare wire from power 

supply cable

B. Line 1

C. Hex washer head screw
D. Silver-colored terminal 

block screw

E. Line 2
F. Neutral (white) wire

G. UL listed strain relief and 

power supply cable

A. Insert wire under screw clamp.
B. Hex washer head screw

A

C

B

A

B

C

D

E

F

G

A

B

Summary of Contents for RF362LXTQ

Page 1: ... potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can ki...

Page 2: ...cm beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The floor anti tip bracket must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See Electrical Requirements section IMPORTANT To avoid damage to your cabinets check with yo...

Page 3: ...the ground path is adequate Do not use an extension cord Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 WARNING Improper connection of...

Page 4: ...t be revised so the green ground wire of the 4 wire power supply cord is connected to the cabinet See Electrical Connection Grounding through the neutral conductor is prohibited for new branch circuit installations 1996 NEC mobile homes and recreational vehicles or an area where local codes prohibit grounding through the neutral conductor When a 4 wire receptacle of NEMA Type 14 50R is used a matc...

Page 5: ...unt anti tip bracket to wood floor drill two 3 2 mm holes at the positions marked on the bracket template Remove template from floor To mount anti tip bracket to concrete or ceramic floor use a 4 8 mm masonry drill bit to drill 2 holes at the positions marked on the bracket template Remove template from floor 6 Tap plastic anchors into holes with a hammer 7 Align anti tip bracket holes with holes ...

Page 6: ...ve cover from range 3 Add strain relief Style 1 Power supply cord strain relief Remove the knockout for the power supply cord Assemble a UL listed strain relief in the opening Tighten strain relief screw against the power supply cord WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instructions ...

Page 7: ...ct the neutral center wire to the center terminal connector using one of the hex washer head screws Securely tighten screw for proper electrical connection 5 Connect the other 2 wires lines 1 and 2 to the outer aluminum terminal blocks 6 Securely tighten screws for proper electrical connection 7 Tighten strain relief screws 8 Replace terminal block cover A Removable retaining nut B Strain relief I...

Page 8: ...hicles In an area where local codes prohibit grounding through the neutral 1 Remove the ground link screw from the range frame Save the ground link screw and cup washer Bend the ground link away from the range so that it does not contact the range 2 Connect the bare ground wire to the range using the ground link screw and cup washer The ground wire must be attached first and must not contact any o...

Page 9: ...t secure the range to the floor Any method of securing the range is adequate as long as it conforms to the standards in the Location Requirements section LevelRange 1 Place rack in oven Place level on rack and check levelness of range first side to side then front to back If range is not level pull range forward until rear leveling leg is removed from the anti tip bracket On Ranges Equipped with S...

Page 10: ...qualified technician MovingtheRange When moving range slide range onto cardboard or hardboard to avoid damaging the floor covering If removing the range is necessary for cleaning or maintenance For power supply cord connected ranges 1 Unplug the power supply cord 2 Slide range forward to complete cleaning or maintenance 3 Check that anti tip bracket is installed Look for the anti tip bracket secur...

Page 11: ...11 ANTI TIP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall Left edge Top edge ...

Page 12: ...W10141166A 2007 All rights reserved 7 07 Printed in U S A ...

Reviews: