23
Low Ice Production
•
Step 1: Check Freezer temperature
(optimal 0°F, ±3°F)
– Adjust Freezer temperature as needed
• L
ower Temp for More Ice
Note: The average temperature of the
Iceland ice maker compartment is 15
degrees F. (The set point of the ice
maker compartment is 25 degrees if the
icemaker switch is turned "off").
Step 1:
Check Freezer temperature (optimal 0°F, ±3°F)
Adjust Freezer temperature as needed
Lower Temp for More Ice
Note:
The average temperature of the Iceland ice maker compartment is 15 degrees
F. (The set point of the ice maker compartment is 25 degrees if the icemaker switch
is turned “off”).
•
Step 2: Check size and quality of cubes
– If undersized, check and diagnose water supply
• P
lugged screen on water valve?
• F
rozen or partially plugged fill tube?
• W
ater pressure too low?
• Refrigerator hooked up to Reverse Osmosis filter
?
• Water supply hooked up to Self-Piercing water
valve?
Is enough water being supplied to the icemaker?
Small or undersized cubes are usually an indication that there’s not enough water
entering the icemaker. Cubes should all be about the same size (between 2⅜ and 2⅝
in length).