Remote controller

Insert the batteries into RC

1.  Insert a pin and gently press down on the battery 

cover and push in the direction of the arrow to 

remove, as shown.

2.  Insert 2 AAA batteries (1.5V) into the compartment. 

Ensure that “+” and “-” polarity is correctly positioned.

3.  Close the battery cover on the remote control.

  Remote Control presetting

Each time the batteries are replaced in the remote 

controller, the remote controller pre-set at Heat Pump 

mode. The heat pump AC remote controller can be used 

to control the cool only AC models.

•   The remote control will operate the air conditioner at a 

distance of up to 7m.

Use RC to control the appliance

•   To operate the appliance by remote control, point the 

remote control at the receiving device on the indoor 

unit, to ensure receiving sensibility.

•   To send a message from remote control, the symbol 

will flash for 1 second. On receipt of the message, the 

appliance will emit a beep.

Note: please follow the instruction which matches to the remote controller you receive for Air Conditioner 

operation.
Function description of buttons

1.

    ON  OFF  BUTTON

Starts and/or Stops the appliance by pressing this button.

2.

   MODE  BUTTON

Used to select the operation mode.

3.

   FAN  BUTTON

Used to select fan speed in sequence auto, high,  medium or low.

 4-5.   TEMPERATURE  BUTTON

Used to select the room temperature. Used to set time in timer mode and 

real time clock.

6. 

 AUTO  BUTTON

Sets or cancels 6th Sense operation.In this mode,temperature and fan speed 

are automatically set based on the actual room temperature.

7. 

 SWING  BUTTON

Stops or starts horizontal adjustment louver swinging and sets the desired 

up/down airflow direction.

8. 

 JET  BUTTON

Used to start ir stop the fast cooling or heating.

9.   AROUND U BUTTON

Used to start or cancel Around U function.When you press this 

button,remote control transmits the actual room temperature around it to 

the indoor unit,and the appliance will operate according this temperature to 

let you feel more comfortable. 

10.   TIMER  BUTTON

Used to set or cancel the timer on operation.

Used to set or cancel the timer off operation.

11.   SLEEP  BUTTON/DIM

1 - Short press, sets or cancels Sleep Mode operation. Sleep Mode can be set 

in Cooling, Heating or Dry operation mode, this function gives you a more 

comfortable environment for sleep.

2 - Long press, press 3 seconds to turn on or turn off display light on unit.

Note:Under extreme environmental conditions,it is possible to notice a temporary slight increase in noise due to the need of reaching the 
comfort temperature quickly.

Symbols on RC display

1

2
3

6

11

9

5

7

4

10

 8

Cooling indicator

Auto fan speed

Auto indicator

Signal transmission

Dry indicator

High fan speed

Jet indicator

Display set timer

Fan only indicator

Medium fan speed

Around U indicator

Display set temperature

Heating indicator

Low fan speed

Signal receptor

Summary of Contents for PACF212HPW

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ...Young children 3 8years should be kept away from the appliance unless continuously supervised Children from 8years old and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge can use this appliance only if they are supervised or have been given instructions on safe use and understand the hazards involved Children must not play with the applian...

Page 5: ...ce make sure that it has not been damaged during transport In the event of problems contact the dealer or your nearest After sales Service Once installed packaging waste plastic styrofoam parts etc must be stored out of reach of children risk of suffocation The appliance must be disconnected from all remote power supply before any installation operation risk of electric shock During installation m...

Page 6: ......

Page 7: ...c heater Do not pierce or burn Be aware that the refrigerants may not contain an odor Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification Servicing sh...

Page 8: ...e atmospheres Ensure that hte leak detection equipment being used is suitable for use with flammable refrigerants i e non sparking adequately sealed or intrinsically safe 6 5 Presence of fire extinguisher If any hot work is to be conducted on the refrigerating equipment or any associated partsappropriate fire extinguishing equipment shall be available to hand Have a dry powder or CO2 fire extingui...

Page 9: ...cannot be corrected immediately but it is necessary to continue operation an adequate temporary solution shall be used This shall be reported to the owner of the equipment so all parts are advised Initial safety checks shall include That capacitors are discharged this shall be done in a safe manner to avoid possibility of sparking That there no live electrical components and wiring are exposed whi...

Page 10: ...ion equipment shall be calibrated in a refrigerant free area Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas 25 maximum is confirmed Leak detection fluids are also suitab...

Page 11: ...ioning A follow up leak test shall be carried out prior to leaving the site 14 Decommissioning Before carrying out this procedure it is essential that the technician is completely familiar with the equipment and all its detail It is recommended good practice that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall be taken in case analysis ...

Page 12: ...ion Before using the recovery machine check that it is in satisfactory working order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant Waste Transfer N...

Page 13: ......

Page 14: ...room temperature Used to set time in timer mode and real time clock 6 AUTO BUTTON Sets or cancels 6th Sense operation In this mode temperature and fan speed are automatically set based on the actual room temperature 7 SWING BUTTON Stops or starts horizontal adjustment louver swinging and sets the desired up down airflow direction 8 JET BUTTON Used to start ir stop the fast cooling or heating 9 ARO...

Page 15: ...n the dishwasher or use any chemical cleaners 5 Air dry filter completely before replacing to ensure maximum efficiency 6 Reattach the air filter to the filter panel door 7 Reinstall filter panel door 8 Press ON OFF to start the air conditioner Cleaning the Outside 1 Unplug air conditioner or disconnect from power 2 Remove the air filter and clean separately See Cleaning the Air Filter 3 Wipe outs...

Page 16: ...ow exhaust adapter into the flexible exhaust hose Both the coupling and window exhaust adapter have integral clips that snap onto the hose flexible exhaust hose coupling window exhaust adapter exhaust hose assembly 3 Insert the coupling into the slot on the back of the air conditioner 4 Slide down to lock the hose into place 5 Confirm the hose is locked in place before operating A Flexible exhaust...

Page 17: ... which floor area larger than 12 m and higher than 2 2 m Local air conditioners are designed as supplemental cooling to local areas within a room To ensure proper ventilation keep the required distance from the return air outlet to the wall or other obstacles at least 23 1 2 60 cm Do not block air outlet Provide easy access to grounded outlet The universal WPRO branded Window Kit are available onl...

Page 18: ... within a room A higher capacity air conditioner may be required depending on the size of the room being heated up Air conditioner runs for a short time only but room is not cool or hot Set temperature is close to room temperature Lower or Higher set temperature See Operating mode description Display error code If the unit display error code E5 it is water full in the unit you should drain the wat...

Page 19: ...the number shown on the warranty booklet or follow the instructions on the website www whirlpool eu When contacting our Client After sales service always specify a brief description of the fault the type and exact model of the appliance the service number number after the word Service on the rating plate The service number is also indicated on the guarantee booklet your full address your telephone...

Reviews: