To guarantee the unit working normally, please read the manual carefully before installation,
and try to install strictly according to this manual.
Earth the air conditioner properly.
Warning: Risk of electric shock can cause injury or death: Disconnect all Remote electric power
supplies before servicing .
Caution: Mount with the lowest moving parts of indoor unit at Least 2.4m above floor or grade Level.
Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner.
After installing, the consumer must operate the air conditioner correctly according to this manual,
keep a suitable storage for maintenance and move of the air conditioner in the future.
Type of fuse used on indoor unit controller is
, with rating 2.5A/250V or 3.15A/250V. .
Φ
5
×
20
There must be an air-break switch.
Installation instructions
Notes
Check the connecting cables and pipes carefully, make sure they are correct and firm before
connecting the power of the air conditioner.
The maximum length of the connecting pipe between the indoor unit and outdoor unit should be less
than 5 meters. It will affect the efficiency of the air conditioner if the distance longer than that length.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
The appliance shall be installed in accordance with national wiring .
How to Purge Air Tubes:
1. Connect IDU & ODU connecting piping.
2. Connect the Manifold Gauge & Vaccum Pump to the charging valve.
3. Do the system evacuate atleast for 30 minutes with two stage vaccum pump when reaching a vaccum
of 10mm Hg absolutes, switch off the pump & hold the vaccum for 5 minutes and check
if the vaccume is breaking or not.
4. If vaccum breaks, then there is a leakage in system.
5. Rectify the leakage and do the vaccum again(Follow repeat of process)
6.If no vaccum breakage, open the spindles of 2-way & 3-way valves.
Then again check leakage with soap suds