background image

19

4. Attach long hose to “Y” connector and tighten

couplings

Attach one of the 5 ft (1.5 m) inlet hose ends to the “Y”
connector. Attach washer cold inlet hose to other side of “Y”
connector. Screw on coupling by hand until it is seated on
connector. Using pliers, tighten the couplings an additional
two-thirds turn.

NOTE:

Do not overtighten. Damage to the coupling can

result.

5. Attach long hose to dryer fill valve and tighten

coupling

If applicable, remove protective cap from water inlet valve.
Attach other end of long hose to fill valve on dryer back panel.
Screw on coupling by hand until it is seated on fill valve
connector. Using pliers, tighten the couplings an additional
two-thirds turn.

NOTE:

Do not overtighten. Damage to the coupling can

result.

NOTE:

The Steam Dryer water connection may be in a

different location.

6. Turn on cold water faucet

Check that the water faucet is turned on.

7. Check for leaks

Check for leaks around “Y” connector, faucets, and hoses.

Connect Vent (Vented Models Only)

1. Connect vent to exhaust outlet

Using a 4" (102 mm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure vent is clean.
Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.

2. Move dryer to final location

Move dryer to final location. Avoid crushing or kinking the
vent. After dryer is in place, remove corner posts and
cardboard from under dryer.

Level Dryer

1. Level Dryer

Check levelness of dryer from side to side. Repeat from front
to back.

NOTE

: The dryer must be level for the moisture-sensing

system to operate correctly.

Summary of Contents for LDR3822PQ - Compact Electric Dryer

Page 1: ...nnexion Internet 23 ENTRETIEN ET RÉPARATION DE LA SÉCHEUSE 24 Nettoyage de l emplacement de la sécheuse 24 Nettoyage de l intérieur de la sécheuse 24 Retrait de la charpie accumulée 24 Nettoyage du filtre à charpie 24 Changement de l ampoule d éclairage du tambour sur certains modèles 25 Vérification d une circulation d air adéquate pour le système d évacuation 25 Pour maintenir une bonne circulat...

Page 2: ...the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed WARNING Risk of Fire Clothes dryer installation must be performed by a qualified installer Install the clothes dryer according to the manufacturer s instructions and local codes Do not install a clothes dryer with flexible plastic venting materials or flexible metal...

Page 3: ...not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product Do not use heat to dry articles containing foam rubber or similarly textured rubber like materials Clean lint screen before or after each load Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint dust and dirt The interi...

Page 4: ...e This Device complies with Industry Canada License exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation of the device Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or l...

Page 5: ... or more often depending on dryer usage Cleaning the Lint Screen Every load cleaning The lint screen may be located either in the door opening or the top of the dryer depending on model A screen blocked by lint can increase drying time To clean 1 Remove the lint screen If necessary press the tab to release and open the lint screen Roll lint off the screen with your fingers Do not rinse or wash scr...

Page 6: ...nd and curve reduces airflow Remove lint and debris from the exhaust hood Remove lint from the entire length of the vent system at least every 2 years When cleaning is complete be sure to follow the Installation Instructions for final product check Clear away items from the front of the dryer Nonuse Storage and Moving Care Nonuse or Storage Care If you will be on vacation or not using your dryer f...

Page 7: ...bulges kinks cuts wear or leaks are found When replacing your inlet hose record the date of replacement INSTALLATION REQUIREMENTS Tools and Parts NOTE Install the clothes dryer according to the manufacturer s instructions and local codes Gather required tools and parts before starting installation Read and follow the instructions provided with any tools listed here Tools Needed for All Installatio...

Page 8: ...Pa You may use the water supply for your washer using the necessary parts as noted which you may need to purchase Level floor with a maximum slope of 1 25 mm under the entire dryer If the slope is greater than 1 25 mm install Extended Dryer Feet Kit If not level clothes may not tumble properly and automatic sensor cycles may not operate correctly For garage installation place dryer at least 18 460...

Page 9: ...uctions provided for it here This dryer is manufactured ready to install with a 3 wire electrical supply connection The neutral bond conductor is permanently connected to the neutral conductor white wire within the dryer If the local electrical codes require the use of a ground fault circuit interrupter a 4 wire electrical supply connection is required thereby the neutral bond conductor must be re...

Page 10: ...connection is adequate and in conformance with Canadian Electrical Code C22 1 latest edition and all local codes A copy of above codes standard may be obtained from Canadian Standards Association 178 Rexdale Blvd Toronto ON M9W 1R3 CANADA To supply the required 4 wire single phase 120 240 V 60 Hz AC only electrical supply on a separate 30 A circuit fused on both sides of the line A time delay fuse...

Page 11: ...leg holes by hand Use a wrench to finish turning legs until diamond marking is no longer visible Place a carton corner post from dryer packaging under each of the two dryer back corners Stand the dryer up Slide the dryer on the corner posts until it is close to its final location Leave enough room to connect the exhaust vent Electrical Installation U S A WARNING Fire Hazard For power supply cord u...

Page 12: ...d the other is pointing down D and hold in place Tighten strain relief screws just enough to hold the two clamp sections C together 2 Attach power supply cord to strain relief Put power supply cord through the strain relief Be sure that the wire insulation on the power supply cord is inside the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal po...

Page 13: ...f terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements Direct Wire Connection Direct wire strain relief 1 Attach direct wire strain relief Unscrew the removable conduit connector A and any screws from a 3 4 19 mm UL listed strain relief UL marking on strain relief Put the threaded section of the strain relief through the hole below the...

Page 14: ...t wire cable under center screw of terminal block B Squeeze hooked ends together and tighten screw 6 Connect ground wire Connect ground wire green or bare F of direct wire cable under green external ground conductor screw A Tighten screw 7 Connect remaining wires Place hooked ends of remaining direct wire cable wires under outer terminal block screws hooks facing right Squeeze hooked ends together...

Page 15: ...w go to Venting Requirements Optional 3 Wire Connection Power Supply Cord Shown IMPORTANT You must verify with a qualified electrician that this grounding method is acceptable before connecting 1 Prepare to connect neutral bond wire and neutral wire Install the correct strain relief for your electrical connection method Remove center terminal block screw B Remove neutral bond wire E from green ext...

Page 16: ...w and poor performance Do not install in enclosed walls ceilings or floors The total length should not exceed 73 4 ft 2 4 m The length of flexible metal vent used must be included in the overall vent system design as shown in the Vent System Chart Home Venting System If using an existing home vent system clean lint from the entire length of the system before installing the dryer Make sure external...

Page 17: ... Over The Top installation also available with one offset elbow Periscope installation Special provisions for mobile home installations Exhaust vent must be securely fastened to a noncombustible portion of the mobile home and must not terminate beneath the mobile home Terminate exhaust vent outside Determine vent path Select route that will provide straightest and most direct path outdoors Plan in...

Page 18: ...l exhaust hood Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood 2 Connect vent to exhaust hood Vent must fit over the exhaust hood Secure vent to exhaust hood with 4 102 mm clamp Run vent to dryer location using straightest path possible Avoid 90 turns Use clamps to seal all joints Do not use duct tape screws or other fastening devices that extend in...

Page 19: ...amage to the coupling can result NOTE The Steam Dryer water connection may be in a different location 6 Turn on cold water faucet Check that the water faucet is turned on 7 Check for leaks Check for leaks around Y connector faucets and hoses Connect Vent Vented Models Only 1 Connect vent to exhaust outlet Using a 4 102 mm clamp connect vent to exhaust outlet in dryer If connecting to existing vent...

Page 20: ...er softener is recommended to control the buildup of scale through the water system in the dryer Over time the buildup of lime scale may clog different parts of the water system which will reduce product performance Excessive scale buildup may lead to the need for certain part replacement or repair To change the door swing from a right side opening to a left side opening see online Dryer Door Reve...

Page 21: ...l est le danger potentiel comment réduire le risque de blessure et ce qui peut se produire en cas de non respect des instructions AVERTISSEMENT Risque d incendie L installation de la sécheuse à vêtements doit être effectuée par un installateur qualifié Installer la sécheuse conformément aux instructions du fabricant et aux codes locaux Ne pas installer la sécheuse avec des matériaux d évacuation e...

Page 22: ...ions et d être capable de les exécuter Ne pas utiliser d assouplissant ou de produits pour éliminer l électricité statique à moins que cela ne soit recommandé par le fabricant de l assouplissant ou du produit Ne pas sécher à la chaleur des articles contenant du caoutchouc mousse ou des matières similaires Nettoyer le filtre à charpie avant ou après chaque charge La zone située autour de l ouvertur...

Page 23: ...appareil satisfait aux prescriptions des documents CNR RSS d Industrie Canada utilisation sans licence Le bon fonctionnement de l appareil est fonction de deux conditions 1 Cet appareil ne doit pas produire de brouillage 2 Cet appareil doit être compatible avec n importe quelle interférence y compris des interférences causées par l utilisation involontaire de l appareil En vertu des règlements d I...

Page 24: ...lisation de la sécheuse Le nettoyage doit être effectué par un réparateur qualifié ou un nettoyeur de systèmes de ventilation À l intérieur du conduit d évacuation Il faut retirer la charpie accumulée dans le conduit d évacuation tous les 2 ans ou plus souvent selon l utilisation de la sécheuse Nettoyage du filtre à charpie Nettoyage avant chaque charge Le filtre à charpie peut être situé dans l o...

Page 25: ...soin de chaleur et d une circulation d air adéquate pour sécher efficacement les vêtements Une ventilation adéquate réduit les durées de séchage et accroît les économies d énergie Voir les Instructions d installation Le système d évacuation fixé à la sécheuse joue un rôle important dans la circulation de l air Des conduits d évacuation bloqués ou écrasés ainsi qu une installation inadéquate de l é...

Page 26: ...r que les pieds de nivellement sont solidement fixés à la base de la sécheuse 5 Utiliser du ruban adhésif pour fixer la porte de la sécheuse 6 Sur les modèles avec tringle de base retirer la tringle de base avant de déplacer la sécheuse Consulter la section Installation et retrait de la tringle de base sur certains modèles Hivérisation de la sécheuse 1 Débrancher la sécheuse ou déconnecter la sour...

Page 27: ...limentation de 2 pi 0 6 m Tuyau d alimentation de 5 pi 1 52 m Modèles avec conduit d évacuation Brides de conduit coudes et matériel d évacuation Pièces nécessaires non fournies avec la sécheuse Des pièces supplémentaires seront peut être nécessaires selon l installation Consulter les codes locaux Vérifier l alimentation électrique et le circuit d évacuation existants Voir les sections Installatio...

Page 28: ...n piédestal il faudra 18 po 460 mm jusqu au bas de la sécheuse La sécheuse ne doit pas être installée ou remisée dans un endroit où elle sera exposée à l eau ou aux intempéries IMPORTANT Ne pas faire fonctionner la sécheuse à des températures inférieures à 45 F 7 C À des températures inférieures la sécheuse pourrait ne pas s arrêter à la fin des programmes de détection automatique ce qui entraîner...

Page 29: ... la plaque signalétique sur un circuit séparé et protégé par un fusible ou un disjoncteur de 30 A sur chacun des 2 câbles On recommande également que cet appareil soit alimenté par un circuit indépendant Ne pas installer un fusible dans le conducteur neutre ou le circuit de mise à la terre Ne pas utiliser de rallonge Si les codes le permettent et si on utilise un conducteur distinct de mise à la t...

Page 30: ...que de décharge électrique en offrant au courant électrique un itinéraire d évacuation de moindre résistance L appareil est doté d un cordon électrique comportant un conducteur de mise à la terre d équipement et une fiche de branchement de liaison à la terre La fiche doit être branchée sur une prise de courant appropriée qui soit bien installée et reliée à la terre conformément à tous les codes et...

Page 31: ...lle ne correspond pas à la prise de sortie faire installer une prise appropriée par un électricien qualifié CONSERVER CES INSTRUCTIONS INSTRUCTIONS D INSTALLATION Installation des pieds de réglage de l aplomb AVERTISSEMENT Risque de poids excessif Utiliser deux personnes ou plus pour déplacer et installer l appareil Le non respect de cette instruction peut causer une blessure au dos ou d autres bl...

Page 32: ...e aller à la section Exigences concernant l évacuation Prise de courant à 3 conducteurs NEMA type 10 30R Consulter la section Raccordement du câble d alimentation à 3 fils Ensuite aller à la section Exigences concernant l évacuation Raccordement direct à 4 fils Aller à la section Fixer le serre câbles pour raccordement direct puis Raccordement direct à 4 fils et enfin Exigences concernant l évacua...

Page 33: ...de terre externe verte A 4 Connecter le conducteur neutre et le conducteur neutre Connecter le conducteur neutre E et le conducteur neutre blanc ou centre C du câble d alimentation sous la vis de la borne centrale B Serrer la vis 5 Connecter le conducteur de liaison à la terre Connecter le conducteur vert ou nu de liaison à la terre F du câble d alimentation sous la vis du conducteur de liaison à ...

Page 34: ...duit amovible A et les vis d un serre câbles homologué UL inscription UL sur le serre câbles de 3 4 po 19 mm Visser la partie filetée du serre câbles dans le trou sous l ouverture du bornier B En passant par l ouverture du bornier visser le connecteur de conduit amovible A sur le filetage du serre câbles C et bien serrer 2 Fixer le câble à raccordement direct au serre câbles Passer le câble à racc...

Page 35: ...chet et serrer la vis 6 Connecter le conducteur de liaison à la terre Connecter le conducteur vert ou nu de liaison à la terre F du câble pour raccordement direct sous la vis du conducteur de liaison à la terre externe A Serrer la vis 7 Connecter les conducteurs restants Placer les extrémités en crochet des conducteurs restants du câble pour raccordement direct sous les vis les plus à l extérieur ...

Page 36: ...e aller à la section Exigences concernant l évacuation Raccordement de la connexion à 3 fils optionnelle cordon d alimentation illustré IMPORTANT Il convient de vérifier auprès d un électricien qualifié que cette méthode de mise à la terre est acceptable avant d effectuer le raccordement 1 Préparer la connexion du conducteur neutre au conducteur neutre Installer le bon serre câbles pour votre racc...

Page 37: ...ute déformation susceptible de réduire la capacité d évacuation et le rendement Ne pas installer le conduit métallique flexible dans des cavités fermées de murs plafonds ou planchers La longueur totale ne doit pas dépasser 7 3 4 pi 2 4 m La longueur du conduit métallique d évacuation flexible utilisé doit être prise en compte lors de la conception de l ensemble du circuit d évacuation comme indiqu...

Page 38: ...stallation avec évacuation par la gauche ou par la droite offert seulement sur certains modèles de 27 po de largeur C Installation avec évacuation par le bas offert seulement sur certains modèles de 27 po de largeur Autres installations avec dégagement réduit Il existe de nombreux systèmes d évacuation Choisir le système qui convient le mieux à votre installation Deux installations à dégagement ré...

Page 39: ...clapets d évacuation à persiennes ou de type boîte l évacuation sera meilleure quelle que soit la longueur du circuit Coudes supplémentaires Dans les situations où les instructions d installation n indiquent pas de longueur d évacuation pour un nombre précis de coudes requis pour une utilisation particulière les calculs suivants peuvent être utilisés La longueur totale du système d évacuation comp...

Page 40: ...des extrémités du tuyau d alimentation de 5 pi 1 5 m au connecteur en Y Fixer le tuyau d alimentation en eau froide de la laveuse à l autre extrémité du raccord en Y Visser le raccord à la main jusqu à ce qu il repose sur le raccord Terminer le serrage des raccords de deux tiers de tour supplémentaire avec une pince REMARQUE Ne pas serrer excessivement Le raccord risque d être endommagé 5 Fixer le...

Page 41: ...placement final Placer la sécheuse à son emplacement final Éviter d écraser ou de déformer le conduit d évacuation Une fois la sécheuse en place retirer les cornières et le carton sous la sécheuse Réglage de l aplomb de la sécheuse 1 Réglage de l aplomb de la sécheuse Vérifier l aplomb de la sécheuse dans le sens transversal Répéter l opération dans le sens avant arrière REMARQUE La sécheuse doit ...

Page 42: ...tre dans le circuit d eau de la sécheuse Avec le temps l accumulation de tartre peut obstruer différentes parties du circuit d eau ce qui réduira la performance du produit Une accumulation excessive de tartre peut entraîner la nécessité de remplacer ou de réparer certains composants Pour inverser le sens d ouverture de la porte de la sécheuse consulter la section Instructions pour inversion de por...

Reviews: