93
ELECTRICAL CONNECTIONS
Electrical connection must be made before connecting the
appliance to the electricity supply. The appliance must be
installed by a qualified electrician who is fully aware of current
safety and installation regulations. Specifically, installation must be
carried out in compliance with the regulations of the local
electricity supply company. Make sure that the voltage shown on
the rating plate is the same as the power supply voltage in your
home. Regulations require that the appliance be earthed: use
conductors (including the earth conductor) of the appropriate
size only. The manufacturer declines all liability for injury to
persons or animals and for damage to property resulting from
failure to observe the above regulations. For the electrical
connection use a H05RR-F type cable as indicated in the table
below:
Power supply voltage.
The appliance must be connected to the electricity supply by
means of an all-pole disconnect switch with minimum contact
gap of 3 mm.
Attention: the power supply cable must be long enough to allow
the cooktop to be removed from the worktop and must be
positioned so as to avoid damage or overheating caused by
contact with the base.
Connecting to the terminal board
Note: the yellow/green earth wire must be connected to the
terminal with the symbol
and must be longer than the other
wires.
• Remove approx. 70 mm of the cable sheath from the power
supply cable (B).
• Strip approx. 10 mm of sheath from the wires. Then insert the
power supply cable into the cable clamp and connect the
wires to the terminal block as indicated in the connection
diagram placed close to the terminal block itself.
• Secure the power supply cable (B) by means of the cable
clamp.
• Close the terminal board with the cover (A) securing it with
the screw provided.
• After the electrical connection, fit the hob from the top and
hook it to the support springs, according to the illustration.
Conductors
Amount x size
220-240V ~
+
3 X 4 mm
2
230-240V ~
+
3 X 4 mm
2
(Australia only)
220-240V 3~
+
4 X 1.5 mm
2
380-415V 3N ~
+
5 X 1.5 mm
2
380-415V 2N ~
+
4 X 1.5 mm
2