3
Installation Clearances
27" (68.6 cm) and 30" (76.2 cm) Ovens
Cabinet Side View
Cabinet filler kits are available from your dealer. Use matching
color kit if oven is smaller than your cabinet opening.
27" (68.6 cm) oven filler height is 7
¹⁵⁄₁₆
" (19.8 cm)
Black - 4378950
White - 4378951
Almond - 4378952
30" (76.2 cm) oven filler height is 4
¹³⁄₁₆
" (12.2 cm)
Black - 4378944
White - 4378945
Almond - 4378946
Electrical Requirements
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
Do not ground to a gas pipe.
Check with a qualified electrical installer if you are not sure the
oven is properly grounded.
Do not have a fuse in the neutral or ground circuit.
This oven must be connected to a grounded metal, permanent
wiring system.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/NFPA
70-latest edition or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. O-M91-latest edition, and all local
codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Electrical Connection
To properly install your oven, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
■
Oven must be connected to the proper electrical voltage and
frequency as specified on the model/serial number rating
plate. (The model/serial number rating plate is located on the
oven door or on the oven frame.)
■
Models rated from 7.3 to 9.6 kW at 240 volts (5.5 to 7.2 kW
at 208 volts) require a separate 40-amp circuit. Models rated
at 7.2 kW and below at 240 volts (5.4 kW and below at
208 volts) require a separate 30-amp circuit.
■
A time-delay fuse or circuit breaker is recommended.
■
Connect directly to the fused disconnect (or circuit breaker
box) through flexible, armored or nonmetallic sheathed,
copper cable (with grounding wire). See “Make Electrical
Connection” section.
■
Flexible armored cable from appliance should be connected
directly to the junction box.
■
Do not cut the conduit. Use the length of conduit provided.
■
A UL listed or CSA approved conduit connector must be
provided.
■
If the house has aluminum wiring, connect the aluminum
wiring to the copper wire by using special connectors
designed and UL listed for joining copper to aluminum. Follow
the electrical connector manufacturer’s recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
27" (68.6 cm) models
A. 27" (68.6 cm) min. cabinet
width
B. 1" (2.5 cm) top of cutout to
bottom of upper cabinet door
C. 19
¹⁄₄
" (48.9 cm) bottom of
cutout to floor
D. 25
¹⁄₂
" (64.8 cm) cutout width
E. 1
¹⁄₂
" (3.8 cm) min. bottom of
cutout to top of cabinet door
F. 41
¹⁄₄
" (104.8 cm) cutout height
30" (76.2 cm) models
A.
30
" (76.2 cm) min. cabinet
width
B. 1" (2.5 cm) top of cutout to
bottom of upper cabinet door
C. 19
¹⁄₄
" (48.9 cm) bottom of
cutout to floor
D. 28
¹⁄₂
" (72.4 cm) cutout width
E. 1
¹⁄₂
" (3.8 cm) min. bottom of
cutout to top of cabinet door
F. 41
¹⁄₄
" (104.8 cm) cutout height
A. 23
¹⁄₄
" (59.1 cm) min. cutout depth
B. 23" (58.4 cm) recessed oven depth
C. Oven front
D. Recessed oven
E. Cabinet
A
B
C
D
E
F
A
B
C
D
E