Power supply cord method:

1.

Disconnect power.

2.

Remove the knockout for the 40 amp
power supply cord.

3.

Assemble a U.L.-listed strain relief in
the opening. 

4.

Insert the power supply cord through
the strain relief, allowing enough
slack to easily attach the wiring to the
terminal block.

WARNING

- Improper connection of the

equipment-grounding conductor can
result in a risk of electric shock. Check
with a qualified electrician or serviceman
if you are in doubt as to whether the
appliance is properly grounded. Do not
modify the power supply cord plug. If it
will not fit the outlet, have a proper outlet
installed by a qualified electrician.

This range is manufactured with the
neutral terminal connected to the cabinet.
Use a three-wire, U.L.-listed, 40 amp
power supply cord (pigtail); or if local
codes Do not permit ground through the
neutral, use a four-wire power supply
cord rated at 250 volts, 40 amps and
investigated for use with ranges. (See
“Four-wire electrical connection.”)

5.

Use either ring-type terminals or
spade terminals with upturned ends
to connect the power supply.

6.

Complete electrical connection
according to your type electrical
supply (“Four-wire electrical
connection” or “Three-wire electrical
connection.”)

Four-wire electrical connection:

Use this method for new installations,
mobile homes, recreational vehicles and
whenever four-wire installation is
required.

7.

Remove the ground-link screw from
the range frame. Save the ground-link
screw. Bend up the ground link so
that it does not contact the range. See
Figure 1.

8.

Connect the green ground wire from
power supply cord to the range using
the ground-link screw. The ground
wire must be attached first and must
not contact any other terminal. See
Figure 2.

9.

Use 3/8" nut driver and remove the
outside nuts on the terminal block
screws. Do not loosen the factory-
tightened nuts behind the outside
nuts.

10. Connect the neutral wire (center wire)

to the center terminal screw on the
terminal block. See Figure 2.

11. Connect the other two wires (lines 1

and 2) to the outer screws on the
terminal block. See Figure 2.

12. Securely tighten nuts with 3/8" nut

driver for proper electrical
connection.

13. Tighten the strain relief screws.

14. Replace the terminal block cover.

15. Plug power supply cord into

grounded electrical outlet.

Three-wire electrical
connection:

Use this method only if local codes
permit connecting cabinet-ground
conductor to neutral wire of power
supply cord.

7.

Use 3/8" nut driver and remove the
outside nuts on the terminal block
screws. Do not loosen the factory-
tightened nuts behind the outside
nuts.

8.

Connect the neutral wire (center wire)
to the center terminal screw on the
terminal block. See Figure 3.

9.

Connect the other two wires (lines 1
and 2) to outer terminal screws on the
terminal block. See Figure 3.

10. Securely tighten nuts with 3/8" nut

driver for proper electrical
connection.

11. Tighten the strain relief screws.

12. Replace the terminal block cover.

13. Plug power supply cord into

grounded electrical outlet.

NOTE:

The bag containing three

aluminum terminal lugs is not used
when connecting the range using a
power supply cord.

Electrical Shock Hazard

Disconnect power before servicing.

Use new 40 amp power supply cord.

Plug into grounded outlet.

Failure to follow these instructions can
result in death, fire, or electrical shock.

WARNING

U.L.-listed strain relief
and 40 amp range
power supply cord

ground
link

neutral
(center wire)

line 2

line 1

center
terminal
block screw

remove knockout
for 40 amp
power cord 
and U.L. listed
strain relief

opening for
conduit
connector

U.L. listed strain relief
and 40 amp range
power supply cord

neutral wire
(center wire)

line 1

line 2

green 
ground
wire

Figure 2

center
terminal
block screw

ground-link
screw

ground link

Figure 3

ground
link

ground-link
screw

Figure1

Summary of Contents for GR450LXHQ2

Page 1: ...ct the anti tip bracket if the range is moved Failure to follow these instructions can result in death or serious burns to children and adults 10 10 10 www whirlpool com IMPORTANT Installer Leave Installation Instructions with the homeowner Homeowner Keep Installation Instructions for future reference Read and save these instructions for local electrical inspector s use Write down the model and se...

Page 2: ...g codes and ordinances Failure to meet codes and ordinances could lead to fire or electrical shock Proper installation is your responsibility A qualified technician must install this range Make sure you have everything necessary for correct installation It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating pla...

Page 3: ...floor 30 76 2 cm width 24 1 2 62 2 cm 26 3 8 67 0 cm depth with handle 36 91 4 cm cooktop height 46 13 16 119 0 cm overall height 3 Product dimensions Cabinet dimensions requirements NOTE 24 61 cm min when bottom of wood or metal cabinet is protected by not less than 1 4 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm alu...

Page 4: ...orage drawer panel A four wire or three wire single phase 120 240 volt 60 Hz AC only electrical supply or three wire or four wire 120 208 volt if specified on the model serial rating plate is required on a separate 40 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Copies of the standards listed may be obtained from National Fire Protection Associati...

Page 5: ...minum wire depending on the connection needed terminal block cover knockout opening for 40 amp power supply cord knockout opening for power supply cable 8 Remove the terminal block cover located on the back of range Contact a qualified floor covering installer for the best procedure for drilling mounting holes through your type floor covering 7 Use the anti tip bracket template to install the anti...

Page 6: ...crews Do not loosen the factory tightened nuts behind the outside nuts 10 Connect the neutral wire center wire to the center terminal screw on the terminal block See Figure 2 11 Connect the other two wires lines 1 and 2 to the outer screws on the terminal block See Figure 2 12 Securely tighten nuts with 3 8 nut driver for proper electrical connection 13 Tighten the strain relief screws 14 Replace ...

Page 7: ...ral white wire into the hole at the bottom of the center position lug attached to center terminal screw black terminal block See Figure 2 13 Connect the other two wires lines 1 and 2 to the outer aluminum lugs 14 Securely tighten the set screws For 8 gauge copper wire tighten to 25 in lbs of torque and for 6 gauge aluminum wire tighten to 35 in lbs of torque to make a proper electrical connection ...

Page 8: ...tion section 14 Place rack in oven Place level on rack first side to side then front to back anti tip bracket range foot 12 Make sure the anti tip bracket is installed Look for the anti tip bracket securely attached to floor Slide range back so rear range foot is under anti tip bracket If range is not level pull range forward until rear leveling leg is removed from the anti tip bracket Use 3 8 dri...

Page 9: ... light The TEMP indicator will turn off The display will show the automatic countdown time needed to preheat the oven to the selected temperature 350 and begin counting down The bottom element should glow red The upper element should become hot but not glow red 3 Press the OFF CANCEL or CANCEL pad NOTE The oven will not go through preheat if the oven temperature is above 170 F instead the TEMP ind...

Page 10: ...d Major Service and Repair or Call the Customer Interaction Center The toll free number is listed in your Use and Care Guide When you call you will need The range model number The range serial number Both numbers are listed on the model serial rating plate located on the oven frame behind the storage drawer panel When moving range slide range onto cardboard or hardboard to prevent damaging the flo...

Page 11: ...11 Notes ...

Page 12: ...12 Part No 9758641 Printed in U S A 2004 Whirlpool Corporation Benton Harbor Michigan 49022 01 2004 ...

Reviews: