15
Base Grille Water Filtration System
Model T1WG2L/T2RFWG2 Capacity 200 Gallons (757 Liters)
Model T1WG2/T2RFWG2 Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
■
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
■
Use replacement filter T2RFWG2, part #4396841.
2009 suggested retail price of $39.99 U.S.A./$54.95 Canada.
Prices are subject to change without notice.
Model T1WG2L: Style 1 – When the filter indicator reads 10%,
order a new filter. When the indicator reads 0%, it is
recommended that you replace the filter.
Style 2 – When the filter indicator changes from green to yellow,
order a new filter. When the indicator changes from yellow to red,
it is recommended that you replace the filter.
Style 3 – When the water filter status display changes from
“GOOD” to “ORDER,” order a new filter. When the filter indicator
reads “REPLACE,” it is recommended that you replace the filter.
Style 4 – Press FILTER to check the status of your water filter. If
the filter indicator light is yellow, order a new filter. If the filter
indicator light is red, it is recommended that you replace the filter.
Model T1WG2: Change the water filter cartridge every 6 months.
If the water flow to the water dispenser or ice maker decreases
noticeably before 6 months have passed, replace the water filter
cartridge more often.
■
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
■
The product is for cold water use only.
■
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
■
Refer to the “Warranty” section for the Manufacturer’s name,
address and telephone number.
■
Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate
Class II*; and against NSF/ANSI Standard 53 for the reduction of Mercury,
Benzene, Toxaphene, O-dichlorobenzene, and Carbofuran.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Chlorine Taste/Odor
Particulate Class II
*
50% reduction
85% reduction
2.0182 mg/L
1333333 #/mL
2.0 mg/L ± 10%
At least 10,000 particles/mL
0.06 mg/L
6600 #/mL
**
0.0536 mg/L
2325 #/mL
97.03
99.51
97.34
99.83
Contaminant
Reduction
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Lead: @ pH 6.5***
Lead: @ pH 8.5***
0.010 mg/L
0.010 mg/L
0.1533 mg/L
0.1400 mg/L
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.0005 mg/L
0.0007 mg/L
0.0005 mg/L
0.0006 mg/L
99.67
99.50
99.67
99.57
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.002 mg/L
0.002 mg/L
0.0058 mg/L
0.0059 mg/L
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.0002 mg/L
0.0005 mg/L
0.0002 mg/L
0.0003 mg/L
96.54
91.57
96.54
94.92
Benzene
0.005 mg/L
0.0154 mg/L
0.015 mg/L ± 10%
0.0012 mg/L
0.0006 mg/L
92.22
96.34
O-Dichlorobenzene
0.6 mg/L
1.7571 mg/L
1.8 mg/L ± 10%
0.0250 mg/L
0.0066 mg/L
98.58
99.63
Toxaphene
0.003 mg/L
0.015 mg/L
0.015 mg/L ± 10%
0.001 mg/L
0.001 mg/L
93.33
93.33
Carbofuran
0.04 mg/L
0.0819 mg/L
0.08 mg/L ± 10%
0.0400 mg/L
0.0213 mg/L
51.13
74.00
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi
*
**
***
Class II particle size: 1 um to <5 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
Compliant for Lead reduction requirements under NSF/ANSI Standard 53 as tested by Pace Analytical Services, Inc.
® NSF is a registered trademark of NSF International.