27
ENGLISH
Natural gas
(Methane)
G20
Liquefied
petroleum gas
(Butane)
G30
Liquefied
petroleum gas
(Propane)
G31
Semi-rapid
Semi-rapid
Semi-rapid
Auxiliary
Auxiliary
Auxiliary
Type of gas
used
Type of
gas used
Model configuration
Rated
power
kW
Total
rated
consumption
Air required (m³)
for burning 1 m³
of gas
Type of burner
Injector
marking
Rated
power
kW
Reduced
power
kW
Rated
consumption
rat.
max.
Table of injectors
Electric supply: 220-240 V - 50/60 Hz
2.5 Technical characteristics
Category II2H3B/P Type Class 3
G20 20 mbar
G30 30 mbar
G31 30 mbar
1R - 2SR - 1 AUX
7,90
762 l/h
9,52
1R - 2SR - 1 AUX
8,00
581 g/h
30,94
1R - 2SR - 1 AUX
8,00
581 g/h
30,94
136 B
93 P
93 P
97 A
66 A
66 A
78 A
50
50
3,50
3,50
3,50
1,70
1,75
1,75
1,00
1,00
1,00
333 l/h
254 g/h
254 g/h
167 l/h
127 g/h
127 g/h
95 l/h
73 g/h
73 g/h
2,20
1,90
1,90
0,30
0,40
0,40
0,30
0,35
0,35
17
25
25
20
30
30
25
35
35
Rapid
Rapid
Rapid
•
The electrical installation of this product
should be performed by authorized
service Whirlpool or by a trained
technician of your trust.
•
Appliance voltage is indicated on the data
plate.
•
When installing the cooktop, provide a
circuit breaker which must have a
minimum gap of 3 mm among contacts.
Manual W10777748.indd 27
Manual W10777748.indd 27
02/09/15 09:23
02/09/15 09:23