2-1
INSTALLATION INFORMATION
L.P. GAS CONVERSION
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
NOTE: Gas conversion from natural to L.P.
gas must be done by a qualified installer.
To convert the cooktop for use with L.P. gas,
perform the following steps.
1. Unplug cooktop or disconnect power.
2. Turn off gas supply to cooktop.
3. Use a screwdriver and remove the ac-
cess cap on the gas distribution valve.
Access Cap
Gas Distribution
Valve
4. Turn the access cap over so that the let-
ters L.P. are facing up, and then reinstall
the cap on the valve.
NAT Position
L.P. Position
5.
To convert the cooktop burners for
use with L.P. gas:
a) Remove the grates and burner caps.
Grates
Burner Cap (4)
b) Remove the two screws from the burn-
ers and remove the burners from the
cooktop.
Burners
Burner Screws
(
30
˝
Cooktop Shown
)