4-6
REMOVING THE STIRRER MOTOR
6.
Lift the left end of the top cover and prop it
up so you can access the stirrer motor.
1.
Unplug the microwave oven or disconnect
the power.
2.
Remove the cabinet (see page 4-2 for the
procedure).
3.
Remove the two front and two rear top
cover screws (see steps 4c and 4d on
page 4-5).
4.
Remove the humidity sensor ground wire
screw from the rear panel.
NOTE:
Sharp edges may be present.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
Ground Wire Screw
Rear Panel
Humidity Sensor
7.
Remove the screws from the motor and
disconnect the wire connectors from the
motor terminals.
8.
Open the microwave oven door.
9.
Use a putty knife and pry the stirrer motor
cover with the plastic nails and bushings
off the top of the oven cavity.
Stirrer Motor
Wires
Screw (1 of 2)
Raise & Prop Up
Top Cover
5.
Slide the top cover to the left and unhook
the four front locking tabs in the cover with
the slots in the chassis, (see photo in step
4d on page 4-5 for the tab locations).
Stirrer Motor Cover