4. Install the pressure regulator with the arrow pointing up
toward the bottom of the cooktop base and in a position
where you can reach the regulator access cap.
IMPORTANT: All connections must be wrench-tightened. Do not
make connections to the gas regulator too tight. Making the
connections too tight may crack the regulator and cause a gas
leak. Do not allow the regulator to turn on the pipe when
tightening fittings.
Use only pipe-joint compound made for use with Natural and LP
gas.
Do not use TEFLON
®
tape. You will need to determine the fittings
required depending on your installation.
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
3. Remove surface burner caps, burner base and grates from
parts package. Align notches in burner caps with pins in
burner base.
Align orifice holder in burner base with igniter electrode.
Burner caps should be level when properly positioned. If
burner caps are not properly positioned, surface burners will
not light. Place burner grates over burners and caps.
4. Plug into a grounded 3 prong outlet.
A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Up arrow. Regulator must be installed with
arrow pointing up to cooktop bottom.
A. Closed valve
B. Open valve
A
B
C
D
A
B
A. Orifice holder
B. Burner cap
C. Gas tube opening
D. Burner base
E. Igniter electrode
B
C
D
E
A
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING