S E R V I C E
Whirlpool Europe
FL 5085
11.11.2002 / Page 3
Customer Service
8570 508 10050
Doc. No: 4812 712 17681
Technical data
Drain pump (synchronous)
Nominal Voltage
230
V
Nominal/max. current
0.3/0.5
A
Nominal power
35
W
Frequency
50
Hz
Resistor (coil) (20 ˚C)
162
Ω
Motor protection
Thermal-fuse
Capacity (0.55 - 1.0 m)
20
±
2
l/min
Position of draining hose
outlet
min.
0.55
m
max.
1.0
m
Program timer
Type
SC1 - 3330
Timer basic
4619 710 67586
Timer programmed
4619 753 00211
Nominal voltage
230
V
Frequency
50
Hz
Program
Positions
32
Motor
Type
MCA 45/64 - 148/
TAT 1
Belt ratio
i = 1:15.91
Resistance contacts (20 ˚C)
Stator (full field)
2.07
Ω ±
7%
Stator (tapped field)
1.32
Ω ±
7%
Rotor
2.00
Ω ±
7%
Tachogenerator
67.80
Ω ±
7%
Input power (at 230 V AC)
Washing
250
W
±
7%
Rinsing
310
W
±
7%
Spinning
380
W
±
10%
Radio interference supression
Rated voltage
90 - 250
V
Rated current
16
A
Frequency
50/60
Hz
Nominal capacity
470 nF X1 + 2 x 22 nF Y
Main switch
Type
1DLF1006
Nominal voltage
250
V
Nominal current
16 (5)
A
Poles
2
Functionality
Normally opened
Connection in RAST 5
6.3
pins
Connection lamp
2.8
pins
Pilot lamp
Nominal voltage
230
V
Option switch
Nominal voltage
5
V DC
Nominal current
1
mA
Poles
1
Functionality
Normally opened
Connection
RAST 2.5
Temperature/spin speed selector
Positions
7
Nominal voltage
5
V DC
Nominal current
1
mA
Poles
1
Connection
RAST 2.5
Value of resistors
±
5%:
5 - 6
Position 1
<10
Ω
Position 2
0.68
k
Ω
Position 3
1.10
k
Ω
Position 4
1.80
k
Ω
Position 5
2.70
k
Ω
Position 6
3.60
k
Ω
Position 7
4.70
k
Ω
Push button switch
ON/OFF
SM
Rapid
OPT. 1
Rinse intensive
OPT. 2
Rinse stop
OPT. 3
Cotton-/
coloured
Easy
care
Deli-
cate
Wool
Silk
Pre wash
02 - 06
03 - 06
04 - 06
-
-
Main wash
07 - 21
12 - 21
14 - 21
17 - 21
18 - 21
Rinse
22 - 28
22 - 28
22 - 28
22 - 28
22 - 28
Spin
29 - 31
29 - 31
29 - 31
29 - 31
29 - 31
Stop
32
32
32
32
32