Page 1: ...EveOvens Compactors Room Air Conditioners Dehumidifiers Automatic Washers Clothes Dryers Freezers Refrigerator Freezers Ice Makers Oishwash ...

Page 2: ... cable The flexible armored cable extending from the appliance should be connected directly to the junction box The junction box should be located as shown in Figure 4 on page 3 so that as much slack as possible remains in the cable between the box and the appliance so that it can be moved if servicing is necessary C A suitable strain relief must be provided to attach the power supply cord to the ...

Page 3: ...Provide Electrical Install the junction box under the cabinet and run the Connection 1 20 240 Volt or 120 208 Volt if specified on nameplate AC wire from the maln circuit panel DO NOT connect the wire to the circuit panel at this time For basic information see Electrical Requirements on page 2 3 ...

Page 4: ...Blower Housing will not be positioned at the proper angle for venting To correct simply grasp the Blower Housing and rotate it to the proper angle needed for your installation application See Figures 5 6 THROUGH THE FLOOR INSTALLATION Peninsula or Island Installation Shown BLOWER HOUSING Install between floor joists following dimensions shown below CENTER LINE OF EXHAUST VENT w 5 3 4 ikOM CENTER I...

Page 5: ...mance it IS suggested that no more than three 90 elbows with 6 or 3 l 4 x 10 duct be used 1Maximum Calculated Length 1 26 feet I When using flexible tubing 6 System Calculation Maximum allowable calculated length 26 feet 3 l 4 x 10 System Calculation MaxImum allowable calculated length 26 feet 90 Elbows b 6 Ft Wall 1 90 Elbow 3 l 4 x 10 Wall Cap 1 6 to 3 1 4 xlO Elbow t 2 90 Elbows 5 Ft Ea 10 Ft S...

Page 6: ...See Figure 8 NOTE Because of the length of the Venting Adapter the Blower Housing should be rotated downward in order to clear the cabinet opening Insert unit into countertop opening and tighten hold down bolts at each end of unit as shown in Figure 9 Install the cooking components in the surface unit For the correct installation procedure see Use and Care Guide in the Literature Package ENT ADAPT...

Page 7: ...IRE out of the end of the supply cable of the appliance See Figure 12 Connect the white wire from the supply cable to the neutral wire in the junction box Connect the black or brown and red wire from the supply cable to the corre sponding wires in the junction box The green or bare wire must now be used to ground the appliance in accord ance with local electrical codes Connect the green colored co...

Page 8: ...igan dial 800 632 2243 from Alaska or Hawaii dial 800 253 1121 Dial just es you normally dial long distance A special operator will tell you the name and number of your nearest Whirlpool TECH CARE service outlet During normal working hours Whirlpool consultants et this same number will also answer any questions about operating or maintaining your appliance not covered in your Use and Care Guide Le...

Reviews: