39
Before Use
DEHUMIDIFY
1. Press “POWER” key to turn on the dehumidifier, lights up
2. LED displays the ambient humidity
3. I
n the first time
, the mode will base on current humidity to change the fan speed automatically. And set
the swing angel as the largest one
lights up.
4.
If
it is not the first time
,
p
ress “MODE” key until
5.
Press “FAN SPEED” key to select fan speed
High fan speed Medium fan speed Low fan speed
6. Press “SWING” key to select vertical louver swing angle
Air
F
low
F
ront-up
F
ront-down
Remarks 1 : When choosing different angle of the louver, louver will
be
swing to the largest angle
for
10 seconds
first
,
and then
move to the selected option.
Remarks 2: Press the Air flow icon again, louver will stop
as is.
7.
Timer
setting
Press “TIMER” to set the dehumidifying duration. The“hr”on the top left corner of display will flash
,
Press the “TIMER” or “HUMIDITY” key to select the duration with sequence 1 -> 2 -> 3-> ……>11->
12-->CO(CONTINUOUS). The dehumidifier will stop when time is up.
8.
Humidity
setting
Press “HUMIDITY” to set the desire ambient humidity(RH%). The “%” on the top right corner of display
will flash , the desire RH% by pressing the “HUMIDITY” or “TIMER” key to select the humidity.
“TIMER” increases the RH% with sequence 40% -> 50% -> 60% -> 70% -> 80% -> CO (continuous)
and “HUMIDITY” in decreasing sequence 80% -> 70% -> 60% -> 50% -> 40% -> CO (continuous),
5 seconds later, display will show the current ambient humidity. When the ambient humidity is lower
than selected humidity. The display will show the current ambient humidity. At that moment, the
compressor will stop operation. But the fan will keep operate. The machine will stop automatically
when the ambient humidity is lower than 30%.
9.
Press “POWER” to stop the machine, Machine will continuous to operate for
10 seconds
Then, it
will stop operation. (For details of 'INTERNAL DRY", please refer to
P.
4
7
)
•
when
the
w
ater
t
ank is full (P.4
2
)
•
when the
temperature or humidity
is out of operation range
(P.38)
•
Press "CO"(continuous)
,
the
unit
will stop automatically after
48
hours operation.
If
water tank
was
taken out during operation , the counting time will start over again.
•
When
the unit
is off
,
the user can pre-set the operation time
. For example, press 01, that's mean it
will turn on automatically after 1 hour.
CAUTION
Remark: Machine will stop
under following situation:
Summary of Contents for DS201NB
Page 4: ...2 1 導風板左右擺動調節鈕 5 水箱防漏蓋 2 導風板 6 水箱 3 控制面板 7 水位顯示位置 4 隱藏式把手 產品概述 抽濕機簡圖 正面 ...
Page 27: ......
Page 53: ......