Power Cord
Ground
Wire Nut
Strain Relief Clamp Screws
Wht / Yel / Blk Wires
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
NOTE:
Sharp edges may be present.
1.
Disconnect the power to the drying cabi-
net.
2.
Remove the component panel (see page
4-2 for the procedure).
3.
To remove the power cord:
a) Remove the nut from the ground wire
stud, and remove the green power cord
wire from the stud.
b) Loosen the two power cord strain re-
lief clamp screws.
c) Loosen the 3 wire screws in the cabi-
net-mounted terminal block, pull the
black, white, and green/yellow power
cord wires out of the terminals, and re-
move the cord from the cabinet. NOTE:
Make sure that you reconnect the cor-
rect wires to the terminal block screws,
as shown in the photo.
4.
To remove the cabinet-mounted termi-
nal block:
a) Perform step 3c.
b) Remove the two cabinet-mounted ter-
minal block screws, and remove the
block from its mounting bracket.
REMOVING THE POWER CORD AND
CABINET-MOUNTED TERMINAL BLOCK
Terminal Block Screws
Electrical Shock Hazard
Connect ground wire to ground screw.
Failure to do so can result in death or
electrical shock.
WARNING
4-9
Wire Terminal Screws