Installation clearances:

The location must be large enough to allow the dryer door to 

open fully.

 

Dryer Dimensions

 

   

   

 

   

B

*29

1

/

2

"

(749 mm)

A

43"

(1092 mm)

27"

(687 mm)

23

3

/

4

"

(603 mm)

*29

1

/

2

"

(749 mm)

43"

(1092 mm)

27"

(687 mm)

13

3

/

4

"

(349 mm)

A. Large opening side-swing door

B. Wide opening hamper door

*Most installations require a minimum 5½" (140 mm) clearance   

 behind the dryer for the exhaust vent with elbow. See “Venting  

 Requirements.”

minimum installation spacing for recessed area or 

closet installation

The dimensions shown following are for the minimum spacing 

allowed.

Additional spacing should be considered for ease of 

 

installation and servicing.
Additional clearances might be required for wall, door, and 

 

floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is 

 

recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation 

 

openings in the top and bottom of the door are required.  

Louvered doors with equivalent ventilation openings are 

acceptable.
Companion appliance spacing should also be considered.

 

minimum Required Spacing

 

A

B

C

    18"*

(457 mm)

  1"

(25 mm)

27"

(686 mm)

        1"

   (25 mm)

        1"*

    (25 mm)

14" max.*

(356  mm)

 

  29

¼"

(743 mm)

   

5

½"*

 (140 mm)

  48 in.

  

(310 cm )

2

*

2

  

24 in.

(155 cm )

*

2

       

3"*

(76 mm)

       

3"*

(76 mm)

A. Recessed area

B. Side view - closet or confined area

C. Closet door with vents

*Additional spacing recommended

mobile home - Additional installation requirements

This dryer is suitable for mobile home installations. The 

installation must conform to the Manufactured Home 

Construction and Safety Standard, Title 24 CFR, Part 3280 

(formerly the Federal Standard for Mobile Home Construction  

and Safety, Title 24, HUD Part 280).

mobile home installations require:

Metal exhaust system hardware, which is available for 

 

purchase from your dealer.
Special provisions must be made in mobile homes to 

 

introduce outside air into the dryer. The opening (such  

as a nearby window) should be at least twice as large  

as the dryer exhaust opening.

Electrical Requirements

It is your responsibility:

To contact a qualified electrical installer.

 

To be sue that the electrical connection is adequate and in 

 

conformance with the National Electrical Code, ANSI/NFPA 

70-latest edition and all local codes and ordinances. 

 

The National Electrical Code requires a 4-wire power supply 

connection for homes built after 1996, dryer circuits involved 

in remodeling after 1996, and all mobile home installations. 

 

A copy of the above code standards can be obtained from: 

National Fire Protection Association, One Batterymarch Park, 

Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt, 

 

60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt 

electrical supply, if specified on the serial/rating plate) on a 

separate 30-amp circuit, fused on both sides of the line. A 

time-delay fuse or circuit breaker is recommended. Connect 

to an individual branch circuit. Do not have a fuse in the 

neutral or grounding circuit.
Do not use an extension cord.

 

If codes permit and a separate ground wire is used, it is 

 

recommended that a qualified electrician determine that the 

ground path is adequate.

Electrical Connection

To properly install your dryer, you must determine the type of 

electrical connection you will be using and follow the instructions 

provided for it here.

If local codes do not permit the connection of a neutral 

 

ground wire to the neutral wire, see “Optional 3-wire 

connection” section.
This dryer is manufactured ready to install with a 3-wire 

 

electrical supply connection. The neutral ground wire is 

permanently connected to the neutral conductor (white wire) 

within the dryer. If the dryer is installed with a 4-wire electrical 

supply connection, the neutral ground wire must be removed 

from the external ground connector screw (green screw), and 

secured under the neutral terminal (center or white wire) of 

the terminal block. When the neutral ground wire is secured 

under the neutral terminal (center or white wire) of the terminal 

block, the dryer cabinet is isolated from the neutral conductor.

Summary of Contents for Centennial MEDC700

Page 1: ...m 13 Level Dryer 13 Connect Vent 13 Complete Installation 14 Reverse Door Swing Optional 14 Electric Dryer Installation Instructions 27 Wide Models U S A Only Para obtener acceso al manual de uso y cuidado en español o para obtener información adicional acerca de su producto visite www whirlpool com Tenga listo su número de modelo completo Puede encontrar el número de modelo y de serie dentro de l...

Page 2: ...instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word...

Page 3: ... supply cord rated 120 240 volt minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends A UL listed strain relief Location Requirements You will need A location allowing for proper exhaust installation See Venting Requirements A separate 30 amp circuit If you are using power su...

Page 4: ...e dryer exhaust opening Electrical Requirements It is your responsibility To contact a qualified electrical installer To be sue that the electrical connection is adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances The National Electrical Code requires a 4 wire power supply connection for homes built after 1996 dryer circuits ...

Page 5: ...ord Use a UL listed power supply cord kit marked for use with clothes dryers The kit should contain A UL listed 30 amp power supply cord rated 120 240 volt minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends A UL listed strain relief If your outlet looks like this If your o...

Page 6: ...nals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock Electrical Connection Options If your home has And you will be connecting to Go to Section 4 wire receptacle NEMA Type 14 30R A UL listed 120 240 volt minimum 30 amp dryer power supply cord 4 wire connection Power supply cord 3 wire receptacle NEMA type 10 30R A UL listed 120 240 vol...

Page 7: ...train relief Put the threaded section of the strain relief C through the hole below the terminal block opening B Reaching inside the terminal block opening screw the removable conduit connector A onto the strain relief threads A B C Put direct wire cable through the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position Tighten strain relief ...

Page 8: ...leted your electrical connection Now go to Venting Requirements 3 wire connection Power supply cord Use where local codes permit connecting cabinet ground conductor to neutral wire A B D C E F G A 3 wire receptacle NEMA type 10 30R B 3 wire plug C Neutral prong D Spade terminals with upturned ends E 3 4 19 mm UL listed strain relief F Ring terminals G Neutral white or center wire 1 Loosen or remov...

Page 9: ...nal block hook facing right squeeze hooked end together and tighten screw as shown 1 Remove center silver colored terminal block screw B 2 Remove neutral ground wire E from external ground conductor screw A E A B 3 Connect neutral ground wire E and place the hooked end hook facing right of the neutral wire C white or center wire of direct wire cable under the center screw of the terminal block B S...

Page 10: ...e neutral wire C white or center wire of power supply cord cable under center silver colored terminal block screw B Tighten screw E B C 3 wire connection Direct wire Use where local codes permit connecting cabinet ground conductor to neutral wire Direct wire cable must have 5 ft 1 52 m of extra length so dryer can be moved if needed Strip 3 89 mm of outer covering from end of cable Strip insulatio...

Page 11: ...ng vent system if necessary to achieve the best drying performance Only rigid or flexible metal vent shall be used for exhausting If this is a new vent system Vent Material Use a heavy metal vent Do not use plastic or metal foil vent 4 102 mm heavy metal exhaust vent and clamps must be used DURASAFE venting products are recommended 4 102 mm heavy metal exhaust vent DURASAFE vent products can be pu...

Page 12: ...e A B B C D E F G H I A Dryer F Rigid metal or flexible metal vent B Elbow G Vent length necessary to connect elbows C Wall H Exhaust outlet D Exhaust hood I Optional side exhaust outlet E Clamps Optional exhaust installations This dryer can be converted to exhaust out the right side left side or through the bottom If you prefer you may contact your local dealer to have the dryer converted WARNING...

Page 13: ...turn to the chart Number 90 turns or elbows Type of vent Box louvered hoods Angled hods 0 Rigid metal 64 ft 20 m 58 ft 17 7 m 1 Rigid metal 54 ft 16 5 m 48 ft 14 6 m 2 Rigid metal 44 ft 13 4 m 38 ft 11 6 m 3 Rigid metal 35 ft 10 7 m 29 ft 8 8 m 4 Rigid metal 27 ft 8 2 m 21 ft 6 4 m Install Vent System 1 Install exhaust hood Use caulking compound to seal exterior wall opening around exhaust hood 2 ...

Page 14: ...inutes open the dryer door and feel for heat If you feel heat cancel cycle and close the door If you do not feel heat turn off dryer and check the following There may be 2 household fuses or circuit breakers for the dryer Check that both fuses are intact and tight or that both circuit breakers have not tripped If there is still no heat contact a qualified technician NOTE You may notice an odor whe...

Page 15: ...that attach 2 plugs D on the left side Attach plugs to right side using the same 4 screws 9 Insert screws into bottom holes on left side of cabinet Tighten screws halfway Position door so large end of door hinge slot is over screws Slide door up so screws are in bottom of slots Tighten screws Insert and tighten top screws in hinges 10 Close door and check that door strike aligns with door catch C ...