background image

SERVICE

Whirlpool EMEA
Customer Services

8592 336 10008, 08/28/08

page 3 of 53

Pos

12NC

Description

480 0

4812 321 78422

Cable DOM-MOT6-EU

490 0

4819 321 18136

Cable mains 2m SA

491 0

4812 321 28367

Strain relief

491 1

4812 502 38152

Screw 4.8x19

521 0

4801 111 00091

Control unit DOMINO, programmed

521 0

4812 214 70725

Control unit DOMINO,C1W-basic

571 0

4812 271 28558

Valve,magnet

581 0

4812 271 28585

Pressostat 50/25 INVENS.

620 0

4812 239 58046

Module E3/4 Opt.

630 0

4812 280 58048

Door lock

653 0

4812 134 18046

Light guide Prog. Flow

653 1

4812 134 18047

Guide,light Start low

653 2

4812 134 48361

Guide,light 4 opt.

653 3

4812 134 48362

Guide,light options low

691 0

4812 282 19485

Sensor NTC

701 0

4812 530 29329

Hose, inlet; EN 11770 Reflex

702 0

4812 530 29406

Hose valve-dispenser

707 5

4812 310 19102

Nozzle

708 1

4812 530 49392

Bend disp.-tub Eureka

711 0

4812 418 68379

Dispenser 3 ch.

712 0

4812 418 68381

Drawer

713 0

4812 418 68382

Safety device

718 0

4812 526 48226

Siphon

718 1

4812 418 89066

Separator

754 0

4812 530 29495

Drainhose tub-pump Eureka

754 1

4812 530 28832

Lock eco

760 0

4812 480 58385

Filter pump

781 0

4812 530 29496

Hose draining

782 0

4812 530 29497

Hose Pressostat

794 2

4812 401 18549

Clamp hose

900 0

4812 255 18298

Holder outlet hose

900 1

4812 290 88123

Bracket eureka

900 2

4812 401 18501

Clamp hose 19.2 mm

900 3

4812 401 18853

Cable clamp

900 4

4812 401 18414

Clamp hose

900 5

4819 401 18529

Clamp hose

900 8

4812 401 18854

Holder outlet hose

910 0

4812 505 18427

Nut M6 with washer

910 1

4812 502 48344

Screw

911 7

4812 903 08196

Screw M 5X14-Z; M 5X14-Z

930 0

4812 492 38419

Spring suspension-EUREKA

961 0

4812 532 68151

Spacer

965 0

4812 466 68936

Cover

993 0

4819 530 29028

U Curve for outlet hose

993 3

4812 395 58004

Tool

© Whirlpool EMEA

www.scc-service.com

Summary of Contents for AWO/D 43115

Page 1: ...ervice Bulletin 4812 712 40340 29 Service Bulletin 4812 712 40347 43 Service Bulletin 4812 712 40317 44 Service Bulletin 4812 712 40320 45 Service Bulletin 4812 712 40348 46 Service Bulletin 4812 712 40327 48 Service Bulletin 4812 712 40313 49 Service Bulletin 4812 712 40330 50 Service Bulletin 4812 712 40314 51 Service Bulletin 4812 712 40305 52 This document is only intended for qualified techni...

Page 2: ... Door Lock 135 1 4812 498 18262 Door safety erk 135 2 4812 491 48004 Spring Door Safety 135 3 4812 290 68153 Holder adjust Door Safety 140 0 4812 450 59812 Door glass DELTA EUREKA 143 0 4812 440 11141 Glassdoor frame 144 0 4812 440 11595 Frame door glas 144 3 4812 502 18669 Screw 4 0x12 191 0 4812 460 68633 Door bellow eureka 473 50lt 191 1 4812 492 18028 Strap Eureka 191 2 4812 492 98011 Strap 20...

Page 3: ...10 19102 Nozzle 708 1 4812 530 49392 Bend disp tub Eureka 711 0 4812 418 68379 Dispenser 3 ch 712 0 4812 418 68381 Drawer 713 0 4812 418 68382 Safety device 718 0 4812 526 48226 Siphon 718 1 4812 418 89066 Separator 754 0 4812 530 29495 Drainhose tub pump Eureka 754 1 4812 530 28832 Lock eco 760 0 4812 480 58385 Filter pump 781 0 4812 530 29496 Hose draining 782 0 4812 530 29497 Hose Pressostat 79...

Page 4: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 4 of 53 Exploded View Whirlpool EMEA www scc service com ...

Page 5: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 5 of 53 Exploded View Whirlpool EMEA www scc service com ...

Page 6: ...a Volume 44 l Wash speed 54 rpm Spinning max 1000 rpm Pressostat Level1 11 12 14 Overflow 11 16 Door lock Kind of switch Switch with PTC heater of bimetal Nominal voltage 230 90 264 V Locking time 6 s Unlock time 85 s Inlet valve Nominal voltage 220 240 V 50 Hz Rated flow 1 5 5 bar 8 l min Pressure range 0 3 10 bar Nominal resistance 20 C 3 8 kΩ Drain pump Nominal voltage 220 240 V 50 Hz Total pow...

Page 7: ... 95 C 1 1 kΩ Motor Resistance contacts 20 C Stator full field 2 04 Ω Rotor 2 25 Ω Tacho generator 68 7 Ω Control unit Type DOMINO Nominal voltage 230 V 50 Hz Output control unit Motor M7 6 DSS3 2 40 V Aquastop AQ2 2 DSS3 2 230 V In pump step AQ2 1 DSS3 3 230 V NTC Not measurable Pump DP2 1 DP2 2 230 V Doorlock DSS3 1 DSS3 3 230 V Pressostat E4 E2 230 V empty PR2 1 E2 230 V full PR2 2 E2 230 V Valv...

Page 8: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 8 of 53 Wiring Diagram Whirlpool EMEA www scc service com ...

Page 9: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 9 of 53 Legend Whirlpool EMEA www scc service com ...

Page 10: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 10 of 53 Circuit Diagram Whirlpool EMEA www scc service com ...

Page 11: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 11 of 53 Legend Whirlpool EMEA www scc service com ...

Page 12: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 12 of 53 Program Chart Whirlpool EMEA www scc service com ...

Page 13: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 13 of 53 Program Chart Whirlpool EMEA www scc service com ...

Page 14: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 14 of 53 Program Chart Whirlpool EMEA www scc service com ...

Page 15: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 15 of 53 Program Chart Whirlpool EMEA www scc service com ...

Page 16: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 16 of 53 Program Chart Whirlpool EMEA www scc service com ...

Page 17: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 17 of 53 Program Chart Whirlpool EMEA www scc service com ...

Page 18: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 18 of 53 Program Chart Whirlpool EMEA www scc service com ...

Page 19: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 19 of 53 Program Chart Whirlpool EMEA www scc service com ...

Page 20: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 20 of 53 Program Chart Whirlpool EMEA www scc service com ...

Page 21: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 21 of 53 Program Chart Whirlpool EMEA www scc service com ...

Page 22: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 22 of 53 Program Chart Whirlpool EMEA www scc service com ...

Page 23: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 23 of 53 Program Chart Whirlpool EMEA www scc service com ...

Page 24: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 24 of 53 Testprogram Whirlpool EMEA www scc service com ...

Page 25: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 25 of 53 Error Codes Whirlpool EMEA www scc service com ...

Page 26: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 26 of 53 Error Codes Whirlpool EMEA www scc service com ...

Page 27: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 27 of 53 Error Codes Whirlpool EMEA www scc service com ...

Page 28: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 28 of 53 Error Codes Whirlpool EMEA www scc service com ...

Page 29: ...m or partly blocked outlet system foreign objects wrong assembly of internal or external hoses etc the foam routine is started If during ramp up the wash level L1 is detected the motor stops and the drain pump runs for 30 sec When reaching level L0 within 30sec the ramp up is repeated Depending on the model this can happen up to 3 or up to 5 times If foam creation is the cause then give an advice ...

Page 30: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 30 of 53 Whirlpool EMEA www scc service com ...

Page 31: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 31 of 53 Whirlpool EMEA www scc service com ...

Page 32: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 32 of 53 Whirlpool EMEA www scc service com ...

Page 33: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 33 of 53 Whirlpool EMEA www scc service com ...

Page 34: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 34 of 53 Whirlpool EMEA www scc service com ...

Page 35: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 35 of 53 Whirlpool EMEA www scc service com ...

Page 36: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 36 of 53 Whirlpool EMEA www scc service com ...

Page 37: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 37 of 53 Whirlpool EMEA www scc service com ...

Page 38: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 38 of 53 Whirlpool EMEA www scc service com ...

Page 39: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 39 of 53 Whirlpool EMEA www scc service com ...

Page 40: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 40 of 53 Whirlpool EMEA www scc service com ...

Page 41: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 41 of 53 Whirlpool EMEA www scc service com ...

Page 42: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 42 of 53 Whirlpool EMEA www scc service com ...

Page 43: ...huricht Last Update 11 10 10 VERSION 1 0 TITLE drum lifter SUBJECT Since week 32 2010 are drum lifter with improved fixation feet as spare parts available Since week 31 2010 in production Old and new codes are standardized If the old code is ordered the new one will be deliverd automatically Whirlpool EMEA www scc service com ...

Page 44: ...itions it can occur that the heating element after a short period gets broken caused by very hard water limestone or variations in power supply REMEDIAL ACTION If the heating element gets broken under mentioned conditions we recommend using the alternative heating element that is nickel treated and usable for power supply up to 240V According to SPC 600 pieces will be on stock from week 52 onwards...

Page 45: ...s too hard program selection not possible or program indication is different from selected program Related machines are of production week 10 and 11 2009 REMEDIAL ACTION If such a failure occurs on machines of mentioned production period the rotary program selector has got a mechanical defect The related control units are supplied by Bitron with production week 09 and 10 2009 They have to be excha...

Page 46: ...essure switch failure If the CCU can not properly read the OPEN or CLOSED status of the pressure switch contacts or if the CCU detects during the wash cycle that the pressure switch contact for the wash level L1 11 14 and the pressure switch contact for level empty drum L0 11 12 are CLOSED or OPEN simultanously for 10 sec this failure will be displayed Potential Causes Check the wiring connections...

Page 47: ...SERVICE Whirlpool EMEA Customer Services 8592 336 10008 08 28 08 page 47 of 53 Whirlpool EMEA www scc service com ...

Page 48: ...rogram the board by SAM clean filter If this indication appears but the pump filter and the drain hoses are empty not kinked and well mounted and it is sure that the indication is related to ecoball sticking in the drain hose tub pump even it is already replaced by the new version SB 481271240326 then replace the original control board by the new one and program the board by SAM Only the mentioned...

Page 49: ...ensible failure detection in drive system for safety reasons REMEDIAL ACTION Please check the following points Load Was there bulky load in the drum or was the machine overloaded Drive system Please check the tacho generator resistance and cable Please guarantee a proper and tight seat of the belt on drive shaft and pulley Please check the electrical connections between controls and motor Whirlpoo...

Page 50: ...nlet hose done with a pliers Result is that the valve gets out of its position and brakes the cable connection In addition can be created a short circuit on the control board REMEDIAL ACTION Check the control board for short circuit If necessary exchange the valve Fixate the valve in the correct position with a fixation screw Exchange the harness between control board and valve Check and If necess...

Page 51: ...DIAL ACTION We have some claims about soap dispenser leaking at the connection between dispenser box and distribution plate We recommend exchanging the soap dispenser in the appliance by the new one The mentioned dispenser has got an improved distribution plate Implementation date in production was in week 45 2008 Please keep us informed if you find leakage issues in machines produced after this w...

Page 52: ...stem and especially the separator is designed for REMEDIAL ACTION In case of over foaming at the customer The correct assembly of inlet hose between detergent box and tub has to be checked If it s correct the separator needs to be replaced by a modified one that has got a wider slot expanded from I 1mm to I 2 5mm in the middle in order to increase the flow rate and avoid over foaming New part SC 4...

Page 53: ... flow rate limiter red 8l min has to be removed Then the new one yellow 5 5l min has to be mounted together with the new sieve Original sieve could be too long and destroy the limiter when fixing the inlet hose The set can only be used if the water inlet pressure is higher than 4 bar otherwise there is a risk to create a failure indication of too less water inlet Whirlpool EMEA www scc service com...