GB 11
Description of red indications
Red indication
lights up
(if fitted on your
machine)
Red indication
on display
(if fitted on your
machine)
Description
Causes
Solutions
“Water tap closed”
---
Appliance has no or insufficient water supply. The
“Start/Pause” light flashes.
Check whether:
• Water tap is fully open and water supply pressure
is sufficient.
• Kinks are present in the water inlet hose.
• Mesh filter of water supply hose is blocked (see
“Care And Maintenance”.
• The water hose is frozen up.
• The safety valve inspection window of your water
supply hose is red (provided your appliance has a
water supply hose as shown on picture “B” - see
previous chapter “Care And Maintenance”);
replace the hose by a new one available through
our After-Sales Service or your specialist dealer.
After problem has been removed, restart
programme by pressing “Start/Pause”. If the fault
occurs again, contact our After-Sales Service (see
next chapter).
“Clean pump”
---
Waste water is not pumped out. The appliance
stops in the corresponding programme step; unplug
it and check whether:
• Kinks are present in the drain hose.
• Filter or pump is blocked (see chapter “Removing
The Filter/Draining Residual Water”; make sure
the water has cooled before draining the
appliance).
• The drain hose is frozen up.
After problem has been removed, select and start
the “Drain” programme or push the “Reset” button
for at least 3 seconds; afterwards restart the desired
programme. If the fault occurs again, contact our
After-Sales-Service (see next chapter).