S E R V I C E
Whirlpool Europe
AWM 312/3
09.08.1999 / Page 3
Customer Service
8570 312 53010
Doc. No: 4812 712 14571
Technical data
Drain pump (synchronus)
Nominal voltage
230
V
Nominal current
0.3
A
Nominal consumption
34
W
Frequency
50
Hz
Resistor (coil)
155
±
7%
Ω
Motor protection
no
Capacity (1.25m height)
15 2
l/min
Program timer
Type
Hybridtimer with integreated
electronic
Fab.
EC 4475 (Timer 2b)
Nominal voltage
230
V
Frequency
50
Hz
Total positions
60
Pre wash
pos.
01 - 09
Main wash
pos.
10 - 31
Rinse
pos.
32 - 49
Spin
pos.
50 - 55
Error
pos.
56 - 58
Stop
pos.
59 - 60
Motor
Type
MCA 52/64 - 148 t.f./ WHE0
i = 1 : 13.5
Resistance contacts:
1 - 2
68.7
±
7%
Ω
Collector directly
2.15
±
7%
Ω
5 - 6
1.46
±
7%
Ω
5 - 7
0.65
±
7%
Ω
Radio interference supression
Type
Friburg 26161 C42
Nominal voltage
230
V
Nominal capacity
1FX1+2x22nFY
Nominal inductance
2 x 1
mH
Nominal resistance
470
k
Ω
Temperature switch
Positions
7
Nominal voltage
5
V
Value of resistors:
1 - 2 - 3
internal shunt
4 - 6
internal shunt
5 - 6
pos.1
10
Ω
pos.2
0.68
5% k
Ω
pos.3
1.10
5% k
Ω
pos.4
1.80
5% k
Ω
pos.5
2.70
5% k
Ω
pos.6
3.60
5% k
Ω
pos.7
4.70
5% k
Ω
Spin selector switch
Positions
7
Nominal voltage
5
V
Value of resistors:
1 - 2 - 3
internal shunt
4 - 6
internal shunt
5 - 6
pos.1
10
Ω
pos.2
0.68
5% k
Ω
pos.3
1.10
5% k
Ω
pos.4
1.80
5% k
Ω
pos.5
2.70
5% k
Ω
pos.6
3.60
5% k
Ω
pos.7
4.70
5% k
Ω
Push button switch
Start switch
SST
eco
SEC
Rapid
SR
Pre wash
SPW
Rinse intensive
SRI
Half load
SHL
Rinse stop
SRS