background image

Health & Safety, Use & Care, Installation Guide and

Online Warranty Registration Information

產品安全指引、使用說明、安裝指南及

網上登記保養資料

Model 

產品型號 

AWA07520N

 

/ AWA07520R

 

AWA09220N

 

/ AWA09220R

AWA18020N

 

/ AWA18020R

Summary of Contents for AWA07520N

Page 1: ...Health Safety Use Care Installation Guide and Online Warranty Registration Information 產品安全指引 使用說明 安裝指南及 網上登記保養資料 Model 產品型號 AWA07520N AWA07520R AWA09220N AWA09220R AWA18020N AWA18020R ...

Page 2: ......

Page 3: ...n Instruction Part Identification Operation Operation Tips Caution 16 19 Please read this user manual carefully before operating the air conditioner The description in this user manual may differ from actual unit please refer to the material objects for reference Care and Maintenance Trouble Shooting Guide After Sales Service Safeguarding The Environment Dear User Content lllllllllllllllllllll 14 ...

Page 4: ...shop hotel office library and laboratory and so on Cooling in summer In hot summer air conditioner can cool down room air by transferring heat out Without reducing room temperature air conditioner can dehumidify and make room air dry and comfortable Dehumidifying in rainy or humid season 1 Function Exchange of fresh air Fresh Air Open storm door to keep the fresh air in the room ...

Page 5: ...er the appliance to other users do handover this manual together Installation Precaution The appliance must be fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category III conditions and these means must be incorporated in the fixed wiring in accordance with the wiring rules The air conditioner mus...

Page 6: ...d otherwise it may cause fire hazard Do not pull the power supply cord to remove it from the socket Do not twist or press the power supply cord and make sure it is not broken Do not touch the power plug circuit breaker and emergency button when your hands are wet Disconnect power plug before cleaning maintenance and servicing Disconnect power plug from power supply when the appliance is not in use...

Page 7: ...itioner to breakdown Power requirement Water pipe Special socket must be used Furthermore the socket and wiring must conform to the wiring regulations And the earthing method must be reliable In fixed circuit there must be electricity leakage protection switch of enough power capacity and air switch with enough space Earth wire To ensure the reliable earthing please do not connect earth wire to th...

Page 8: ...er special areas please contact the seller before use Avoid a place where is possible for inflammable gas to leak out It s not allowed to be installed on the unstable or motive base structure such as truck or in the corrosive environment such as chemical factory The condensation water must be drained away conveniently Install air conditioner unit far away from TV set or radio etc to avoid disturbi...

Page 9: ...ine If there is no cover on it you should contact the seller for installing the sunshade board When installing the sunshade board don t let it block the air inlet at the side grille 6 Horizontal line Sunshade board Wall Wooden frame Rubber plate Support Horizontal line Drain water To get the maximum cooling efficiency the air conditioner is designed to splash the condensation water on the condense...

Page 10: ...e electricity leakage protection switch and leakage current is less than 30mA Connecting method between air conditioners and power cord and interconnecting method of each individual element with one another should accord with wiring diagram on the unit The air conditioner should be installed in accordance with national wiring regulations 7 Installation Instruction An all pole disconnection switch ...

Page 11: ...er Air inlet louver Front grille Control panel Panel outlook picture just for reference please take the real until as standard Cabinet Front intake grille Air filter behind the front intake grille Air inlet louver Front grille Control panel Front intake grille Air filter behind the front intake grille Electronic Mechanical Cabinet Panel outlook picture just for reference please take the real until...

Page 12: ...ion at high speed 2 Thermostat Control Knob Setting the desired temperature recommend 4 5 If the room temperature is not as desired after a reasonable period turn the thermostat control knob clockwise to cooler the indoor temperature 3 Air Swing Switch To obtain a fix airflow direction set the air swing switch to ON for the vanes to swing from side to side until the desired flow direction is reach...

Page 13: ...rature The temperature adjusting range is 16 30 Signal receivers Mode button Press this button select operation mode COOL FAN For Electronic only Applicable Models AWA07520R AWA09220R AWA18020R Main Control Panel 10 Press this button to select fan speed High Low Timer After pressing TIMER button press button and time can be set in 1 hour increments Press button and time can be set in 1 hour decrem...

Page 14: ...unlight or any place where is very hot Parts Identification Operations Remote Control 11 Power button Press it to start or stop operation Mode button Press it to select operation mode 6TH SENSE COOL DRY FAN Press it to decrease temperature setting Press it to increase temperature setting Fan speed button Press it to set fan speed Swing button Press it to set swing angle Sleep Timer Press it to set...

Page 15: ...SE mode set temperature is not adjustable Combination of and buttons About lock Press and buttons simultaneously to lock or unlock the keypad Timer Press this button to initiate auto on auto off timer To cancel auto timer program press this button twice Swing button Press this key to activate or deactivate the swing Sleep Press this button to go into the SLEEP operation mode Press it again to canc...

Page 16: ...ir conditioner through the remote controller When unit is on each time you press the button on remote controller the sending signal icon on the display of remote controller will blink once If the air conditioner gives out a beep sound it means the signal has been sent When unit is off set temperature will be displayed on the remote controller If the light of indoor unit display is turned on the co...

Page 17: ...ss phone please get closer to the air conditioner when using the remote controller Parts Identification Operations Replacing batteries in remote controller Using a tool to push the latch 2 Take out old batteries 3 insert the two batteries Two AAA dry cell batteries 4 Re attach the cover Shown as diagram 1 Remove the cover from the back of the remote control To avoid small parts choking hazard it i...

Page 18: ...ing sound may be generated occasionally This phenomena is normal There is condensed water to be formed at evaporator and accumulated at the bottom tray The water will be splashed to condenser through condenser fan blade Splash sound may be created This phenomena is normal Clean the air filter regularly Blockages in the air filter reduce dehumidifying effects Clean the air filter at least once ever...

Page 19: ...on again after you have switched it off during cooling The appliance should not be used by children without supervision Always wait at least 3 minutes 1 The plug must be accessible after the appliance is positioned 2 Do not use this appliance in the laundry room 3 If the power cord is damaged it must be replaced by the manufacture or its service agent in void of hazard Do not pull out the power co...

Page 20: ...essary please ask the professional personnel to clean it Vacuum the filter on the dusty side to remove light dust 4 Vacuum cleaner 3 Wash the filter cleaner side up under gently flowing water to wash out accumulated dust and lint detergent in the wash water If the filter is very dirty use a mild household 1 Air filter The air filter behind the intake grille should be washed at least once every two...

Page 21: ...s because the room humid air has been cooling rapidly The unit is normal while the indoor outlet is sending out some odor because the inlet air may be mixed with the smell of furniture and smoke For a noise that sounds like water flowing This is the sound of freon flowing inside the air con ditioner unit For a noise that sounds like a shower This is the sound of the dehumidifying water being proce...

Page 22: ...fuse or switch often breaks Carelessly splash water or something into air conditioner Electrical lines are much hot or lines cover breaks Other strange situations Immediately stop all operations and plug out please contact your dealer in the following situations 19 ...

Page 23: ...bought the appliance 4 This appliance has been made of recyclable or re usable material Scrapping must be carried out in compliance with local waste disposal regulations Before scrapping it make sure to cut off the mains cord so that the appliance cannot be re used 5 The symbol on the product or on the documents accompanying the product indicates that this appliance should not be treated as househ...

Page 24: ...的宗旨 來設計冷氣機 請在操作冷氣機前 小心閱讀本操作手冊 並適當保存以作日後參考 請在操作冷氣機前細心閱讀本操作手冊 本手冊內的圖示可能與實物有所差異 請根據實物以作參考 目錄 29 35 36 結構及安裝 操作步驟 保養及維修 故障排除指南 售後服務 保護環境 名稱及操作說明 操作指南 注意事項 25 功能 安全注意事項 操作條件 安裝指引 26 28 37 川川川8川川川川川 川川少灶室室穿廾 少室料場丈壬疹 灶系埂汪丈啤 38 川39 壬40 場41 川23 24 21 22 ...

Page 25: ...簡介 在夏季中製冷 在炎熱的夏日 冷氣機可透過抽走熱力來冷凍 房間 冷氣機能在不降低室溫的情況下除濕 令房 間更乾爽及舒適 在雨季或潮濕天氣中除濕 交流新鮮空氣 打開風門來保存室內的新鮮空氣 新鮮空氣 窗口式冷氣機能調節室溫及具除濕效能 為你的工作 溫習及生活帶來便利 冷氣 機能廣泛運用在住宅 商舖 酒店 辦公室 圖書館和實驗室等地方 功能 22 ...

Page 26: ...特別注意以下指引 為了防止人身傷害 傷害他人及產品損壞 用戶應嚴格按照使用說明書 它可能會導致產品損壞或人身傷害 使用電器時 應遵循本說明書的要求 以減少火災 電擊和受傷的風險 請保管好本說明書 如需將產品交給他人使用 請將說明書一同轉交 安裝注意事項 在家中的固定接線系統中需有配有一個符合國家佈接線要求的全極斷開開關 以便 使用時能斷開 冷氣機必須由專業人士或合格的人員進行安裝 安裝產品時需嚴格按照國家的接線要求進行 23 本產品必須接地 且需要接上容量足夠的漏電保護開關 ...

Page 27: ...監護人應確保小孩不能將本產品當成玩具使用 如果電源線損壞 為了避免危險 必須由製造商或指定的維修部門的專業人員更換 嚴禁使用拖線插座供電 以免產品著火 在清洗 維護及維修前需拔下電源插頭 如長時間不使用本產品 需拔下電源插頭 當產品有異味或異音時 請斷開電源並與售後服務聯繫 切勿以拉扯電線的方式來拔出插頭 使用時切勿扭曲或用力按壓電線 並確保電線 沒有損毀 手濕時切勿觸摸插頭 漏電斷路器和緊急操作按鈕 不能使用汽油等易燃清潔劑產品進行清洗 否則會有火災的風險 安全注意事項 24 為了避免本產品太重造成傷害 需2個人或以上移動和安裝本產品 ...

Page 28: ...令壓 縮機及電器組件不能正常運作 要使用特別的電源插座 而且電源插座和線路圖必須符合線 路條例 接駁地線的方法必須可靠 在固定電路中 必須有漏電保護開關 當中必須有足夠的電 力容量 而空氣開關必須有充夠空間 地線 要確保有可靠的地線連接 切勿將地線接駁到以下地方 操作條件 25 製冷模式操作 COOL Mode 室外溫度應該在18 C至43 C之間 否則 冷氣 機可能出現故障 房間濕度應低於90 否則冷氣機表面會出現 水珠 又或當運行一段長時間後 會出現滴 水情況 但這屬正常現象 乾燥模式操作 DRY Mode 室外溫度應該在18o C至43o C之間 否則 冷氣機 可能出現故障 ...

Page 29: ...到的地方 若閣下購買有遙控器的冷氣機 當它安裝在有強力電磁干擾的地方時 在使用前 應先聯絡零售 商以防止出現故障 安裝在適當的位置 以避免操作時產生震動和噪音 請選擇一個周圍沒有障礙物及容易接觸到插 頭的安裝位置 26 頂視圖 前視圖 側視圖 圍欄或 類似物件 超過500 mm 超過 500 mm 少於 220 mm 超過 150 mm 超過 150 mm 天花 超過150 mm 超過 150 mm 請準備一個稍為大於冷氣機尺寸的安裝孔口 請根據下圖選擇安裝位置 安裝時注意事項 D H W 牆壁 牆壁 牆壁 冷氣機與四周障礙物的距離應達到以下要求 大於150毫米 上面 大於150毫米 左面 大於150毫米 右面 大於500毫米 後面 型號 W H D 7K 9K 450 350 580 18K 660 428 700 單位 毫米 產品尺寸 請勿將冷氣機安裝在不穩定或會移動的地方 如大型車輛...

Page 30: ...子 3 用兩枚螺絲將排水盤安裝在機殼的角位 4 將排水管連接至在排水盤底部的排水出口上 6 將底盤滑入機身的原來位置 使用承托支架 安裝孔口必須堅固 可以承托整部冷氣 機 若不穩固 可在室外使用鐵架支撐 鐵架應固定在建築物外牆 如右圖所示 使用太陽擋板 應防止冷氣機上面有物件意外掉下或受陽 光直射 若冷氣機上面沒有上蓋 應聯絡 零售商安裝太陽擋板 當安裝太陽擋板 時 切勿阻礙側面格柵的空氣吸入口 1 從前面板撕去貼紙 2 將冷氣機放入安裝孔口 當安裝冷氣機時 應向後滑入安裝 以防 止增加噪音和震動 傾斜6 10mm 如右 圖所示 冷氣機的安裝位置應夠穩固 以防止增加 噪音和震動 3 使用海綿將框架內的空隙填滿 27 5 在排水盤中倒入2 3杯水 以碓保排水組裝正常 安裝指引 ...

Page 31: ...須按照專業技術員的指令進行 外觀 內觀 排水管 螺絲 排水盤 必須連接可靠的地線 必須使用特定的線路 切勿使用不穩固的插座 因不良接觸可能造成過熱或火災 的危險 切勿用力拉扯電源線 在固定的電路上 應該安裝有漏電保護開關 而漏電電流應少於30mA 應在電路安裝空氣開關 熱磁斷路器 7K和9K的負載能力是10A 而18K是20A 應根據冷氣機的接線圖 使用適當的方法將冷氣機及電源線 以及每個獨立組件 進行相互連接 應根據國際電路規定安裝冷氣機 一個全極斷電開關 在所有電極之間 應有3mm的接觸分離 並應連接到固定的 線路之中 若電源線被損毀 必須由生產商 零售商或合資格的技術人員進行更換以防止危 險發生 所有電氣工程必須根據本地的接線條例進行 安裝指引 28 你可在本地市場購買排水軟管以切合閣下的實際需要 ...

Page 32: ...向 名稱及操作說明 通風桿 當滑動杆桿在 OPEN 當滑動桿在 CLOSE 在 OPEN 開 的位置 通風 在 CLOSE 關 的位置 通風 門開啟讓空氣 煙或異味排 出房間 門關閉 空氣將於室內流通及 調節 29 電子式 冷氣機面板的外觀只作參考 請以實物作為標準 機械式 冷氣機面板的外觀只作參考 請以實物作為標準 機箱 入風格柵 前格柵 過濾網 在前入風格柵的後方 前入風格柵 控制面板 機箱 前格柵 入風格柵 過濾網 在前入風格柵的後方 前入風格柵 控制面板 ...

Page 33: ...OL 中速製冷運轉 HIGH COOL 高速製冷運轉 2 恆溫器控制旋鈕 可按需要 設定恆溫器控制旋鈕 通常是4 5度 當冷氣機 操作一段時間後 房內溫度依然不理想 可將恆溫器控制旋 鈕順時針方向旋轉 令房間溫度變得涼快 或逆時針轉動恆 溫器令室溫提升 3 擺風角度開關 左右調校風向位置 如要固定出風方向 將擺風角度設定到ON 開 的位置 令 其左右搖擺直至達到理想的出風方向 然後控下OFF 關 按 鈕 如須要左右不停擺動 將擺風按鈕 設定至ON 開 的 位置 30 適用型號 AWA07520N AWA09220N AWA18020N ...

Page 34: ...的時間 時間設 定範圍是由0至24小時 訊號接收器 模式按鈕 選擇操作模式 COOL 製冷 FAN 送風 只限電子式 主控制面板 31 電源按鈕 當按下此按鈕 冷氣機會開始運作 再次按下按鈕 運 作會停止 擺風按鈕 啟動自動送風搖擺功能 風速按鈕 按此按鈕選擇風速 高 低 溫度 時間掣按鈕 按下 按鈕 以調高冷氣機的設定 操作 溫度 按 下 按鈕 降低冷氣機的設定 操作 溫度 溫度調節範 圍由攝氏16至30度 定時按鈕 適用型號 AWA07520R AWA09220R AWA18020R 名稱及操作說明 ...

Page 35: ...模式 每次按下此按鈕 選擇不同模式操作 第六感 製冷 抽濕 風速 按下此按鈕減低溫度設定 按下此按鈕提升溫度設定 風速 按此按鈕設定風速大小 搖擺 按下此按鈕設定搖擺角度 睡眠模式 時間制式 按下此按鈕作選擇開啟 關閉時間設定 4 3 8 6 名稱及操作說明 遙控器 32 3 4 5 6 7 8 1 2 請確保在遙控器與接收器之前沒有阻礙物阻擋 請不要拋擲遙控器 切勿在遙控器濺上任何液體以及將遙控器放在直射陽光及非常酷熱的地方 注意 ...

Page 36: ...作關閉此功能 此功能只適用於製冷或抽濕模式 為您提供最舒 適的溫度 睡眠模式運作時 當冷氣機操作1小時後 設定溫度會上升1度 再操作2小時後 設定溫度會再 上升1度 然後保持穩定 8 時間制式 按下此按鈕作設定自動開啟 自動關閉 如要取消時間制操作 連續按下此按鈕兩次即可 9 混合使用 和 按鈕 鎖定功能 同時按下 和 按鈕 便可為遙控鍵盤作鎖定和解鎖 按下此按鈕增加溫度設定 連續按下兩秒以上可加快增加溫度 在第六感模式時 溫度不能作手動 調控 風速 此按鈕用於調控風速 並將按以下次序運行 由第六感操作模式 再回到第六感操作模式 如非指定型號 當 遙控顯示Speed 1或Speed 2 即代表是冷氣低速 而在speed 3或Speed 4時 即代表冷氣高速 屏幕上將同時顯示 AUTO 字樣 而溫度將設定在25度 除濕模式下 風速默認為低風檔 33 1 2 3 4 5 6 7 8 9 遙控器...

Page 37: ...是一款受普遍使用的遙控器 可用於多功能冷氣機 對於沒有某些功能的冷氣機 按遙控器上相應的按 鈕 本機將會保持原來的運行狀態 接上電源後 待機狀態下 可使用遙控器操作冷氣機 開啟冷氣機後 每按一次按鈕 遙控器顯示屏上發出信號圖示 會閃爍 如果冷氣機發出 bee bee 聲 則代表已發出信號 關閉冷氣機後 遙控器會顯示設定溫度 如果顯示屏燈在室內亮起 會顯示相應的圖示 開啟冷氣機 時 則會顯示正在進行的功能圖示 注意 34 ...

Page 38: ...其兩極性 4 重新把遙控器的電池蓋合上 如圖示 更換電池 名稱及操作說明 35 注意 不要將新舊或者不同類型的電池混合使用 當遙控器長時間不使用時 請將電池拆下 電池的使用壽命是1年 遙控器必須放置在遠離電視或者其他電器一米以上 遙控器可能會受到光管 無線電話等信源影響 可靠近冷氣機以改善遙控器接收 移除遙控器的電池蓋 為避免因小零件而引致窒息 請使用工具如一字螺 絲批移除遙控器的電池蓋 先用螺絲批伸入扣位罅隙 輕輕施壓把電池蓋撬起 用工具伸入扣位 罅隙並向前撬起 ...

Page 39: ...向 確保室溫均衡 空氣不能在流入的方向釋出 確保門窗關緊 儘量避免打開門 窗 以保持冷氣在室內流動 定期清潔空氣過濾網 若空氣過 濾網阻塞 會減低除濕效果 至 少每兩星期清潔空氣過濾網一 次 偶爾要排出室內的空氣 由於窗 戶緊閉 應不時打開門窗以保持 室內空氣流通 當冷氣機運作 時 窗簾或門窗應關上 以免流 失冷氣 注意 操作指南 經濟又舒適的操作 36 在寧靜的環境或停止運作時 風扇罩 外殼可能會產生因熱脹冷縮產生的摩擦聲 冷凍劑流動的聲音亦有可能聽到 凝結在蒸發器的水會在底盤裏收集 而冷凝器的風扇會將水淺向冷凝器造成正常的 滴 水 聲 此現象屬正常 ...

Page 40: ...Ζ 3 ૉሽᒵჾᡏΔԫࡳ ط ທ ࢨፂଥ ז ޓ ངΔ א ٲس ᙠΖ 切勿用力拉扯電線 損壞的電源線可以引致嚴重 的觸電危險 切勿使用冷氣機作冷卻房間 以外的用途 切勿使用冷氣機作乾衣 保 存食物或培植蔬菜的用途 切勿阻塞吸風和出風口 以 免降低效能及引致冷氣機不正 常運作 切勿在空氣孔口插入木條或 其他物件 以免在接觸電器組 件及風扇時產生危險 選擇最合適的溫度 小心調節溫度以符合個人 需要 嬰兒 老人或病人 身處的房間應保持合適的溫 度 切勿在附近使用發熱產品 過 熱會令冷氣機的塑膠組件溶化 為健康著想 避免把身體 長時間直接暴露在持續及 單一方向的氣流下 注意事項 安全又健康的操作 37 ...

Page 41: ... ᙰࢸ נ 堚ᑥছ ށ ش ຌؒ 會發生意外 ਢ ܡ ჾᄤ ࢨᠾๅΛ լ౨ੌຏऱ Δ ױ ીய౨ ᛀ ܐ ᖲऱԵଅ נ ଅՑ ॴܡڶ Ⴞ ৱመៀᕴኧࢍ ຘ٦ૹᄅᇘՂΖ ૉ ڶ Ꮑ ழΔ ٻױ റᄐፂଥԳ ᇬ堚ੑऱֱऄΖ 2 ނ መៀጻऀቺ ऱპቺ ܮ ൾΖ 3 堚ੑመៀጻΔ ڇ ᒷᒷऱֽੌՀΔੑ װ ᗨፋऱቺৃΖ 4 ૉመៀጻॺൄᏎᧂΔ ڇױ 堚ੑऱֽխΔ ף Եᄵࡉऱ୮ ش 堚ᑥᕪΖ 2 ࠌ ش ຌؒ堚ᑥᖲߪΖ ૉᖲߪ መᏎᧂΔ ނױ ຌؒ௦ ֽڇ ᄵ攝氏 40৫ א ՀऱᄵֽխΔ ށ ຌؒ ࠀ ᚴ ۆ ढΖ መៀጻ Եଅ ਰ ऱ መៀጻΔᚨ ڶڇ Ꮑ ழΔࢨ ޢ ࠟਣཚ堚ੑԫ ڻ Ζ ڕ ۶堚ੑ መៀጻΚ 1 ฝೈԵଅ ਰΔ ތ ጹመៀጻՂऱ ׂΔྥ ࢮ נ Ζ 保養及維修 清洗主機 38 ...

Page 42: ...於房間潮濕的空氣 被迅速冷卻 偶爾會有霧氣從室內冷氣機釋出 由於吸入的空氣有可能混雜傢具及蒸汽的氣 味 因此室內出風口釋出一些氣味亦屬正常狀 態 聽到像流水的聲音 這是製冷劑在冷氣機內流 動的聲音 當冷氣機的氣流冷卻室內溫暖的空氣時 便會產 生冷凝現象 這是用作保護機械裝置 等候三分鐘 冷氣機會開始運作 製冷效果不佳 沒有 冷氣 釋出有霧空氣 冷氣機操作時發出噪音 冷凝水好像從冷氣機中滲漏 冷氣機在重新啟動後三分鐘未能運作 在維修前 可先查看下表 以節省時間及金錢 室內風速是否調較至LOW 低 的位置 或者房間在冷氣機運作時太熱 是否被陽光直接照射 像淋浴的聲音 這是處理除濕水份在冷氣機內 的聲音 這是正常的 故障排除指南 39 ...

Page 43: ... լ إ ൄ چ ၲࡨࢨೖַᖙ Ι ሽᄭঅᙠ ࢨၲᣂᆖൄሂ Ι լ הࠡࢨֽނ ढᔆែၞ ܐ ᖲփΙ ሽᒵመᑷࢨሽᒵ נ ါฉΙ נ ࠡ ה ൣउΖ ᅝ אس ՀൣउழΔᓮ ܛم ೖַᖙ Δࢸൾ ᙰΔࠀᜤ ᎹՀऱ ሿഇ Ζ 售後服務 40 ...

Page 44: ...置包裝物料 報廢家電 1 包裝物料為100 環保 並且有回收標誌 包裝物料不能分散棄置 必須符合所在當地有關 法規的規定 2 本產品包含製冷劑氣體 為密封系統的氟化溫室氣體 製冷劑氣體 R410a具有了全球警告潛能值 GWP 1975 3 有關處理和回收該產品及其包裝更詳細的信息 請聯繫當地有關機構或您購買本產品的商 店作廢物回收 5 在產品或者產品附帶的文檔中有此標誌表示該產品不能被當作生活垃圾處理 但必須棄於 用作存儲或回收電子 電器產品的地方 6 遙控器中的電池需正確地回收或丟棄 電池應做為有害垃圾由有資質的回收點回收 保護環境 41 ...

Page 45: ...品保養 惠 環保出力 減少用紙 於網上登記產品更可獲額外多一個月保養 Register your product online Save the planet and register your product warranty online Enjoy extra 1 month free warranty upon online registration https rebrand ly WPwarranty ...

Reviews: