background image

5019 318 33292

The hood is designed for use in “Extractor version” or in “Filter version”.

Extractor Version

Fumes are extracted and expelled to the outside through an exhaust pipe (not supplied) fixed to the hood exhaust pipe 
connector (Fig.d, Fig.e).
Depending on the exhaust pipe purchased, provide for suitable fixing to the exhaust pipe connector.
Important: If already installed, remove the carbon filter/s

.

Filter Version

Air is filtered through the carbon filter/s and recycled into the surrounding environment.
Important: check that air recirculation is facilitated (to this end, carefully follow the instructions given in the installation 
handbook)
Important!

 

If the hood does not have a carbon filter/s, it/they must be ordered and fitted before use.

Preliminary information for installing the hood:

Expansion plugs are provided to secure the hood to most types of ceilings. However, a qualified technician is needed to make 
sure that the plugs are suitable for your ceiling. The wall/ceiling must be strong enough to take the weight of the hood. Remove 
the grease filters

Pre-assembly of the electrical connection box:
(

a.

) remove the screws and washers on the extractor unit and remove the adhesive tape fixing the box to the extractor unit, 

(

b.

) position the electrical connection box above the extractor unit, (

c.

) secure with 2 Ø 3.5 x 9.5 screws and 2 

Ø 14 x 12 washers (previously removed).

1.

Using a pencil, draw the centre line on the wall up to the ceiling (Fig.1).

2. If necessary, cut the drilling template according to the width of the hood.

3.

Apply the drilling template to the wall: the vertical centre line printed on the drilling template must match the centre line 
drawn on the wall and, depending on the height of the hood, the lower horizontal edge of the drilling template must match 
the lower edge of the hood.

4.

Drill as shown on the template, insert the wall plugs and screw in the top 2 screws, leaving a space of approx. 1 cm 
between the screw head and the wall.

Note:

 Drill all the holes indicated on the template: the top 2 holes are for hanging the hood and the bottom holes are for 

fixing it securely to the wall.

5.

Fit the flue support bracket “

G

” (Fig.1) to the wall and against the ceiling. Use the support bracket as drilling template (if 

present, the small slot on the support must match the line drawn on the wall) and mark 2 holes with the pencil, drill the 
holes and finally insert 2 plugs.

6.

Fix the flue support bracket to the wall with 2 screws.

7.

Remove the drilling template from the wall and hang the hood on the 2 top screws (Fig.1).

8.

Screw in the bottom screws (and washers!) to fix the hood securely in place (COMPULSORY!!).
After checking the alignment of the hood, TIGHTEN ALL THE SCREWS - top and bottom.

Note: 

the bottom fixing points are visible upon removal of the grease filters.

9.

Connect an exhaust pipe to the exhaust pipe connector located above the extraction motor unit.
For extractor operation, connect the other end of the exhaust pipe to the home discharge device.
For filter operation, fix the deflector 

F

 to the flue support bracket 

G

 and connect the other end of the exhaust pipe to the 

deflector collar 

(Fig.1).

10.

Make all necessary electrical connections.

11.

Fit the flues over the extractor unit, engaging them in their seat above the hood.

12.

Slide the top section of the flue upwards and secure it with 2 screws (11a) to the flue support bracket 

“G”

 (11b).

Refit the grease filters and check for correct hood operation.

I

F

NL

E

P

GB

D

GR

Summary of Contents for AKR 697 IX

Page 1: ...chnician for installation To install follow steps Ö2Ö3Ö WARNING Disconnect the power at the house main switch before electrically connecting the hood WARNING Check whether the exhaust pipe and clamps are provided If not they must be purchased separately Note Parts marked with the symbol are optional accessories supplied only with some models or parts not supplied to be purchased separately WARNING...

Page 2: ... a la señalada deberá aplicarse esa indicación Consulte a un técnico cualificado para la instalación Para el montaje siga la numeración 1Ö2Ö3Ö ADVERTENCIA Desconecte la red eléctrica doméstica antes de efectuar la conexión eléctrica de la campana ADVERTENCIA Compruebe si el tubo de descarga y las abrazaderas de fijación se suministran de serie En caso contrario tiene que comprarlos por separado No...

Page 3: ...essivo la movimentazione e installazione della cappa deve essere fatta da almeno due o più persone ΕΓΚΑΤΑΣΤΑΣΗ ΟΔΗΓΙΕΣ ΤΟΠΟΘΕΤΗΣΗΣ Η ελάχιστη απόσταση ανάμεσα στην επιφάνεια στήριξης των σκευών στη συσκευή μαγειρέματος και στο χαμηλότερο σημείο του απορροφητήρα δεν πρέπει να είναι μικρότερη από 50 cm σε περίπτωση ηλεκτρικών εστιών και από 65 cm σε κουζίνες αερίου ή μικτές Εάν οι οδηγίες εγκατάστασ...

Page 4: ...5019 318 33292 ...

Page 5: ... the components are included Hood assembled with motor and lamps installed Flue support bracket Assembly template Filter s Instruction manual 1 adapter Torx T10 1 adapter Torx T20 2 washers 6 plugs 8 x 40 mm 6 screws 5 x 45 mm 2 screws 2 9 x 6 5 mm 2 screws 3 x 9 mm Fig 1 I F NL E P GB D GR ...

Page 6: ...ctions and or pipes 10 The ventilation ducts must always discharge to the outside 11 The Manufacturer declines any liability for improper use or incorrect setting of the controls 12 The appliance is not intended for use by children or persons with limited physical sensory or mental abilities or without experience and knowledge of it unless they are under the supervision of or instructed in its use...

Page 7: ...od has not been damaged during transport Declaration of conformity This product has been designed manufactured and put on the market in conformity with safety objectives of the Low Voltage Directive 2006 95 EC which replaces 73 23 EEC as amended protection requirements of EMC Directive 89 336 EEC amended by Directive 93 68 EEC Troubleshooting guide If the hood does not work Is the plug properly in...

Page 8: ...emplate must match the centre line drawn on the wall and depending on the height of the hood the lower horizontal edge of the drilling template must match the lower edge of the hood 4 Drill as shown on the template insert the wall plugs and screw in the top 2 screws leaving a space of approx 1 cm between the screw head and the wall Note Drill all the holes indicated on the template the top 2 holes...

Page 9: ... refit it Halogen lamps 1 Disconnect the hood from the mains power supply WARNING Wear gloves 2 Use a small screwdriver to gently prise the lamp cover off at the points indicated in Fig 3 3 Remove the burnt out lamp and fit a new one WARNING Replace using 20W max G4 halogen bulbs only 4 Close the lighting unit snap on Active carbon filter filter hoods only The carbon filter must be cleaned once a ...

Reviews: