WHIRLPOOL CONSUMER SERVICES M
odel AKM160/IX
Page 4 of 9
TECHNICAL DATA
Rating
Gas Jet (Nozzle)
Output Power
Burner
Gas
Type
Operating
Pressure
Diameter Part No
kPa
g/h
l/h
1/100mm
kW
MJ/h
Small
Propane
2.75
65
-
50
506130
920
3.3
N.G.
1.00
-
87
86
506126
920
3.3
Medium Propane
2.75
119
-
68
506131
1670
6.0
N.G.
1.00
-
159
115
506127
16700
6.0
Wok
Propane
2.75
250
-
102
506151
3500
12.6
N.G.
1.00
-
334
165
506152
3500
12.6
Note - 0.165 gas jets: 506152 has short castlation and 506128 (for large burner in other
models) has longer castlation.
GAS LEAKS
After performing any maintenance or service operation on the cooktop, the cooktop must be
checked to ensure that there are no gas leaks.
GAS JET REPLACEMENT
WARNING : Servicing must be carried out only by authorised personnel.
This appliance is approved by the Australian Gas Association for use with either natural gas
or propane gas. Ensure that appliance is suitable for the available gas supply.
To replace a gas jet, the following procedure applies:
1. Turn off the gas cock adjacent to the
cooktop.
2. Remove all the burners and unscrew the
jets using a 7mm socket. See Figure 1.
3. Reinstall the jet appropriate to the gas
supply.
6. Check the cooktop to ensure that there are
no gas leaks
FIGURE 1