background image

S E R V I C E

12.08.1997 / Page 2

AKM 250/WH

Whirlpool Europe

Doc. No: 4812 715 16755

8571 250 35010

Customer Service

Technical data

Type of gas used

Type of

burner

Injector

marking

Rated heat

capacity

PCS-kW

Rated

consumption

Reduced heat

capacity

PCS-kW

Gas pressure (mbar)

min.

rat.

max.

Natural Gas
(Methane)
G 20

large

medium

small

128

94
79

3,00
1,65
1,00

286 l/h
157 l/h

95 l/h

0,60
0,35
0,30

17

20

25

Natural Gas
(Cylinder)
G 30

large

medium

small

85
65
50

3,00
1,65
1,00

218 g/h
120 g/h

73 g/h

0,60
0,25
0,30

20

28-30

35

Natural Gas
(Cylinder)
G 31

large

medium

small

85
65
50

3,00
1,65
1,00

214 g/h

118 g/h

71 g/h

0,60
0,25
0,30

25

37

45

Type of gas used

Appliance

model

Total rated heat

capacity

PCS-kW

Total rated

consumption

Air required for

burning m

3

 /h

G20 20 mbar

4G

7,30

695 l/h

14,6

G30 28-30 mbar

4G

7,30

531 g/h

14,6

G31 37 mbar

4G

7,30

521 g/h

14,6

1. Medium Burner
2. Medium Burner
3. Large Burner
4. Small Burner

Voltage: 230 V
Frequency: 50 Hz

Reviews: