13
Adapting to the different types of gas
Changing the nozzles
1)
Remove the pan standee.
2)
Remove the burner caps and flame caps from the burners.
3)
Use a size 7 socket wrench to unscrew and remove the
nozzles, replacing them with those corresponding to the
type of gas to be used (see the table).
4)
Reassemble the parts, reversing the operations described
above.
5)
Then replace the setting data (close to the mains gas
connection) with the one for the new type of gas If the pressure of the gas used is
different from that specified (or variable), a suitable gas pressure regulator
complying with the standard must be installed on the supply pipeline.
Setting the minimum level
1)
Light the burner as already described.
2)
Turn the tap to the minimum flame position.
3)
Remove the control knobs.
4)
PG TO NG:
Use a thin blade screwdriver to turn the by-pass screw
located above left of the gas valve, shaft as shown right. Turn
gently the by-pass screw clockwise to the end completely
then turn it anti-clockwise 1/2 turn for the Triple flame burner, 3/4 turn for the
Large rapid burner, 1/2 turn for the Medium Semi-rapid Burner
and 3/8 turn for the Auxiliary burner.
NG TO LPG:
Use a thin blade screwdriver to turn the by-pass screw located above left of the
gas valve shaft as shown right. Turn gently the by-pass screw clockwise to the
end.
5)
Finally, check that the burner does not go out when the tap is turned quickly from
the maximum to the minimum position.