Technical data

Flow rates/ Inlet volume

Flow meter (at 0.3 bar = quantity 1.1 l/min)

208

lmp/l

Spray pump

65

l/min

Drain pump

16

l/min

Pump height max.

1.1

m

Inlet valve

4

l/min

Spray arm lower

~ 33

l/min

Sprayarm upper

~ 27

l/min

Sprayarm/ Shower top

~ 8

l/min

Fan for drying:
Total

900

l/min

Primary air flow

210

l/min

Secondary air flow

780

l/min

Electrical base data

Voltage

220/ 230 V

Frequency

50

Hz

Total power

2.0 - 2.2

kW

Fuse

10

A

Spray pump motor permanent spray system

Voltage

220/ 240 V

Power consumption

80

W

Frequency

50

Hz

Resistance

30

Drain pump motor

Voltage

220/ 240 V

Power consumption

30

W

Resistance

146

Fan for drying

Voltage

220 - 240 V

Resistance

141

Heating - 1 Element system

Voltage

220/ 230 V

Power consumption

1.87/ 2.04 kW

Resistance

24.5

Heating speed

~ 2.0

˚C/min

Temperature on surface

~ 115

˚C

Safety thermostat
self reset
(Temperature of water)

~ 85

˚C

Fuse

206

˚C

Water safty options

Waterstop system

Electronic aqua control

Single electric water inlet valve

Voltage

220/ 240 V

Frequency

50/ 60

Hz

Resistance

3.76

k

Regenerating valve

Voltage

220/ 240 V

Frequency

50/ 60

Hz

Resistance

3.13

k

Coil of dispenser

Voltage

220/ 240 V

Frequency

50/ 60

Hz

Resistance

1.3

k

Reed contacts

flow meter

NTC

20 ˚C

58.1

k

25 ˚C

47.1

k

30 ˚C

38.2

k

40 ˚C

25.4

k

50 ˚C

17.2

k

60 ˚C

11.8

k

70 ˚C

8.3

k

80 ˚C

6

k

85 ˚C

4

k

Regeneration

Volume

300

cm

3

after wash cycles

depending on the water
softener setting

water hardness

0 - 40

˚dh

0 - 10.7

mmol/l

0 - 107

˚Fh

Salt consumption
for regeneration

 ~ 77

g

Number of cycles
with 2 kg salt

~ 26

Summary of Contents for ADP 4540 WH

Page 1: ...t 5 6 Exploded view 7 8 Circuit diagram 9 Program diagram 10 Text Legend 11 16 Family WRC EBL LOW 5 Service Manual Dishwasher ADP 4540 WH ADP 4540 WH This documentation is only intended for qualified technicians who are aware of the respec tive safety regulations Date 13 02 2004 Subject to modification Document No 4812 718 19722 ...

Page 2: ...ak by customer A switching off the appliance or unplug the appliance for a while this will frozen the program step and later on the program continuos on the same position Exception Switching off the appliance or unplug the appliance during the drying phase this will lead directly to the end of the program Water Volume at permanent spray system Water Volume Level Regeneration 0 3 l 15 mm Back rinse...

Page 3: ...tance 146 Ω Fan for drying Voltage 220 240 V Resistance 141 Ω Heating 1 Element system Voltage 220 230 V Power consumption 1 87 2 04 kW Resistance 24 5 Ω Heating speed 2 0 C min Temperature on surface 115 C Safety thermostat self reset Temperature of water 85 C Fuse 206 C Water safty options Waterstop system Electronic aqua control Single electric water inlet valve Voltage 220 240 V Frequency 50 6...

Page 4: ...POWER button off to save and exit the water softener setting Accesory If you need spare parts apart from the spare part list have a look in the Service Bulletin 4812 718 40084 Water hardness German degrees dH French degrees fH English degrees Clarke e mmol l Water softener setting is shown by flashing LED 1 soft 0 5 0 9 0 6 3 0 0 9 1 x 1 2 soft medium 6 10 10 18 7 12 6 1 1 8 2 x 2 medium 11 15 19 ...

Page 5: ...59155 Knob 332 0 4812 410 29163 Button START 332 3 4812 410 29166 Button ON OFF 350 2 4812 381 28068 Light guide 400 0 4812 361 58334 Motor SP 50Hz per HP PNT 421 0 4812 121 18158 Interf filter 430 0 4812 360 18508 Pump draining cpl 430 1 4812 466 68689 Gasket Pos No 12NC Code Description 442 0 4812 361 18196 Blower cpl 450 0 4812 259 28684 Heating element 480 0 4812 321 28424 Cable harness EBL wi...

Page 6: ...424 Strap 050 0 901 2 4812 401 18157 Strap 32 50 9 C61 901 5 4812 401 48573 Strap 028 6 904 4 4812 462 79659 Threaded cap 910 1 4812 502 18394 Screw 3 5x14 H 910 2 4812 502 18363 Screw 4 0x12 H 910 3 4812 502 18527 Screw 4x15 T20 910 4 4812 502 18385 Screw M3 5x8 T15M 910 5 4812 502 18393 Screw 3 5x9 1 Tx15 910 7 4812 502 18397 Screw INOX A2 M 5X12 910 8 4812 502 18389 Screw 5x20 T20 910 9 4812 40...

Page 7: ...S E R V I C E Whirlpool Europe ADP 4540 WH 13 02 2004 Page 7 Customer Service 8511 771 10810 Doc No 4812 718 19722 Exploded view ...

Page 8: ...S E R V I C E 13 02 2004 Page 8 ADP 4540 WH Whirlpool Europe Doc No 4812 718 19722 8511 771 10810 Customer Service Exploded view ...

Page 9: ...W Heating IF Interference filter L Line MS Main switch NTC Thermostat temp sensor N Neutral PRG Plug to program RE2 Relay Heating RE3 Relay Spray pump motor RR SA Reed relay salt RR RA Reed relay rinsaid SPM Sprayarm motor THS1 Safety thermostat THS 2 Fuse TBL Power supply terminal TL Winding protective contact UCB User and Control board VM Fan ventilator WV1 Water inlet valve WV2 Water regenerati...

Page 10: ...S E R V I C E 13 02 2004 Page 10 ADP 4540 WH Whirlpool Europe Doc No 4812 718 19722 8511 771 10810 Customer Service Program diagram ...

Page 11: ...S E R V I C E Whirlpool Europe ADP 4540 WH 13 02 2004 Page 11 Customer Service 8511 771 10810 Doc No 4812 718 19722 Text Legend ...

Page 12: ...S E R V I C E 13 02 2004 Page 12 ADP 4540 WH Whirlpool Europe Doc No 4812 718 19722 8511 771 10810 Customer Service Text Legend ...

Page 13: ...S E R V I C E Whirlpool Europe ADP 4540 WH 13 02 2004 Page 13 Customer Service 8511 771 10810 Doc No 4812 718 19722 Text Legend ...

Page 14: ...S E R V I C E 13 02 2004 Page 14 ADP 4540 WH Whirlpool Europe Doc No 4812 718 19722 8511 771 10810 Customer Service Text Legend ...

Page 15: ...S E R V I C E Whirlpool Europe ADP 4540 WH 13 02 2004 Page 15 Customer Service 8511 771 10810 Doc No 4812 718 19722 Text Legend ...

Page 16: ...S E R V I C E 13 02 2004 Page 16 ADP 4540 WH Whirlpool Europe Doc No 4812 718 19722 8511 771 10810 Customer Service Text Legend ...