Technical data

Water softener setting

To change the water softener setting:

Push the POWER button on

Change to program 2

Hold the START button for 5 seconds until the LED is flashing

Water softener setting is shown by flashing LED

By pushing the START button you can change the setting

Push the POWER button off to save and exit the water softener setting

Accesory

If you need spare parts apart from the spare part list have a look in the
Service Bulletin 4812 718 40084.

Water hardness

German degrees

˚dH

French degrees

˚fH

English degrees

Clarke ˚e

mmol/l

Water softener setting is

shown by flashing LED

1 soft

0 - 5

0 - 9

0 - 6,3

0 - 0.9

1 x

1 - 2 soft/ medium

6 - 10

10 - 18

7 - 12.6

1 - 1.8

2 x

2 medium

11 - 15

19 - 27

13.3 - 18.9

1.9 - 2.7

3 x

3 medium/ hard

16 - 21

28 - 37

19.6 - 25.9

2.8 - 3.7

4 x

4 hard

22 - 28

38 - 50

26.6 - 35

3.8 - 5.0

5 x

4 very hard

29 - 35

51 - 63

35.7 - 44.1

5.1 - 6.3

6 x

4 extremely hard

36 - 60

64 - 107

44.8 - 74.9

6.4 - 10.7

7 x

Summary of Contents for ADP 4520 WH

Page 1: ...t 5 6 Exploded view 7 8 Circuit diagram 9 Program diagram 10 Text Legend 11 16 Family WRC EBL LOW 5 Service Manual Dishwasher ADP 4520 WH ADP 4520 WH This documentation is only intended for qualified technicians who are aware of the respec tive safety regulations Date 27 11 2003 Subject to modification Document No 4812 718 19694 ...

Page 2: ...fter pressing the start button for longer then 1 5 sec Break by customer A switching off the appliance or unplug the appliance for a while this will frozen the program step and later on the program continuos on the same position Exception Switching off the appliance or unplug the appliance during the drying phase this will lead directly to the end of the program Water Volume at permanent spray sys...

Page 3: ...ent system Voltage 220 230 V Power consumption 1 87 2 04 kW Resistance 24 5 Ω Heating speed 2 0 C min Temperature on surface 115 C Safety thermostat self reset Temperature of water 85 C Fuse 206 C Water safty options Waterstop system Aquasafe Single electric water inlet valve Voltage 220 240 V Frequency 50 60 Hz Resistance 3 76 kΩ Regenerating valve Voltage 220 240 V Frequency 50 60 Hz Resistance ...

Page 4: ...POWER button off to save and exit the water softener setting Accesory If you need spare parts apart from the spare part list have a look in the Service Bulletin 4812 718 40084 Water hardness German degrees dH French degrees fH English degrees Clarke e mmol l Water softener setting is shown by flashing LED 1 soft 0 5 0 9 0 6 3 0 0 9 1 x 1 2 soft medium 6 10 10 18 7 12 6 1 1 8 2 x 2 medium 11 15 19 ...

Page 5: ...48 Plate handle 331 0 4812 413 59155 Knob 332 0 4812 410 29163 Button START 332 3 4812 410 29166 Button ON OFF 350 2 4812 381 28068 Light guide 400 0 4812 361 58334 Motor SP 50Hz per HP PNT 421 0 4812 121 18158 Interf filter 430 0 4812 360 18508 Pump draining cpl Pos No 12NC Code Description 430 1 4812 466 68689 Gasket 450 0 4812 259 28684 Heating element 480 0 4812 321 28425 Cable harness EBL wit...

Page 6: ...p hose 10 18 mm 901 1 4812 401 18424 Strap 050 0 901 2 4812 401 18157 Strap 32 50 9 C61 901 5 4812 401 48573 Strap 028 6 904 4 4812 462 79659 Threaded cap 910 1 4812 502 18394 Screw 3 5x14 H 910 2 4812 502 18363 Screw 4 0x12 H 910 3 4812 502 18527 Screw 4x15 T20 910 4 4812 502 18385 Screw M3 5x8 T15M 910 5 4812 502 18393 Screw 3 5x9 1 Tx15 910 7 4812 502 18397 Screw INOX A2 M 5X12 910 8 4812 502 1...

Page 7: ...S E R V I C E Whirlpool Europe ADP 4520 WH 27 11 2003 Page 7 Customer Service 8511 763 16810 Doc No 4812 718 19694 Exploded view ...

Page 8: ...S E R V I C E 27 11 2003 Page 8 ADP 4520 WH Whirlpool Europe Doc No 4812 718 19694 8511 763 16810 Customer Service Exploded view ...

Page 9: ...W Heating IF Interference filter L Line MS Main switch NTC Thermostat temp sensor N Neutral PRG Plug to program RE2 Relay Heating RE3 Relay Spray pump motor RR SA Reed relay salt RR RA Reed relay rinsaid SPM Sprayarm motor THS1 Safety thermostat THS 2 Fuse TBL Power supply terminal TL Winding protective contact UCB User and Control board VM Fan ventilator WV1 Water inlet valve WV2 Water regenerati...

Page 10: ...S E R V I C E 27 11 2003 Page 10 ADP 4520 WH Whirlpool Europe Doc No 4812 718 19694 8511 763 16810 Customer Service Program diagram ...

Page 11: ...S E R V I C E Whirlpool Europe ADP 4520 WH 27 11 2003 Page 11 Customer Service 8511 763 16810 Doc No 4812 718 19694 Text Legend ...

Page 12: ...S E R V I C E 27 11 2003 Page 12 ADP 4520 WH Whirlpool Europe Doc No 4812 718 19694 8511 763 16810 Customer Service Text Legend ...

Page 13: ...S E R V I C E Whirlpool Europe ADP 4520 WH 27 11 2003 Page 13 Customer Service 8511 763 16810 Doc No 4812 718 19694 Text Legend ...

Page 14: ...S E R V I C E 27 11 2003 Page 14 ADP 4520 WH Whirlpool Europe Doc No 4812 718 19694 8511 763 16810 Customer Service Text Legend ...

Page 15: ...S E R V I C E Whirlpool Europe ADP 4520 WH 27 11 2003 Page 15 Customer Service 8511 763 16810 Doc No 4812 718 19694 Text Legend ...

Page 16: ...S E R V I C E 27 11 2003 Page 16 ADP 4520 WH Whirlpool Europe Doc No 4812 718 19694 8511 763 16810 Customer Service Text Legend ...

Reviews: